Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability | 200SET/MONTH |
Delivery Time | 2-3weeks |
Packaging Details | Standard Export Box |
Name | Single Phase Portable Electric Meter Calibration Accuracy Class 0.05 |
Accuracy | 0.05% |
Power Supply | One Phase AC 85-265V, frequency 50/60Hz |
Output load | max 50VA |
Harmonic number | 2-51times |
Weight | 8kg |
Brand Name | GFUVE |
Model Number | GF1021 |
Certification | CE, ISO9001 |
Place of Origin | BEIJING CHINA |
View Detail Information
Explore similar products
Handheld 480V Energy Meter Tester 45Hz Kwh Meter Test Equipment
1P2W Harmonic 40Hz Kwh Meter Test Equipment Self Checking
500V Manual Keyboard Electric Meter Calibration 70Hz Overload Protection
Three Phase Electric Meter Calibration TFT Color LCD Electricity Energy Meter
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Supply Ability | 200SET/MONTH |
Delivery Time | 2-3weeks | Packaging Details | Standard Export Box |
Name | Single Phase Portable Electric Meter Calibration Accuracy Class 0.05 | Accuracy | 0.05% |
Power Supply | One Phase AC 85-265V, frequency 50/60Hz | Output load | max 50VA |
Harmonic number | 2-51times | Weight | 8kg |
Brand Name | GFUVE | Model Number | GF1021 |
Certification | CE, ISO9001 | Place of Origin | BEIJING CHINA |
High Light | electrical test equipment calibration ,energy meter calibration equipment |
Single Phase Portable Electric Meter Calibration Accuracy Class 0.05
GF1021 portable single phase energy meter test system used to test single phase energy meter. Adopt mature signal synthetic and power amplifier technology, high precision voltage source and current source output. Widely used in lab and field, and then as single phase standard source.
FEATURES
Accuracy class 0.05
0-120A, 0-500V
Test 3pcs or 2pcs meter synchronously
Start testing and creep testing
Reference standard and power source integrated
Test by automatic or manual
7 inch TFT touch screen
Weight light 8Kg
Recorder 500 sets energy meter data
Overload, short circuit, open circuit protection
PARAMETERS
Electrical parameters | |
Accuracy class | 0.05%, 0.1% |
Power Supply | One Phase AC 85-265V, frequency 50/60Hz. |
AC Voltage Output | |
Range | 57.7V, 100V, 220V, 380V; max 500V |
Adjustment range | (0-120)%RG(1) |
Adjustment fineness | 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. |
Stability | 0.01%/120s |
Distortion | 0.1% (Non-capacitive load) |
Output load | max 30VA |
Measuring accuracy | 0.05%RG |
AC Current Output | |
Range | 200mA, 1A, 5A, 20A, 100A; max 120A |
Adjustment range | (0-120)%RG |
Adjustment fineness | 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. |
Stability | <0.01%/120s |
Distortion | ≤0.1% (Non-capacitive load) |
Output load | max 50VA |
Accuracy | 0.05%RG |
Power Output | |
Active power output stability | <0.01%RG/120s |
Reactive power output stability | <0.02%RG/120s |
Active power measuring accuracy | 0.05%RG |
Reactive power measuring accuracy | 0.1%RG |
Phase Output | |
Output adjustment range | 0°-359.999° |
Output adjustment fineness | 10, 1, 0.1, 0.01 as optional. |
Resolution | 0.01° |
Accuracy | 0.03° |
Power Factor | |
Adjustment range | -1 ~ 0 ~ 1 |
Resolution | 0.0001 |
Measurement accuracy | 0. 0005 |
Frequency Output | |
Adjustment range | 40Hz-70Hz |
Output adjustment fineness | 5Hz, 1Hz, 0.1Hz, 0.01Hz as optional. |
Resolution | 0.001Hz |
Accuracy | 0.005Hz |
Voltage /Current/Harmonic Setting | |
Harmonic number | 2-51times |
Harmonic content | 0-40% |
Harmonic phase | 0-359.99 |
Harmonic setting accuracy | (10%±0.1%)RD(2) |
Power Energy Measurement Error | |
Active power energy | 0.05%RG |
Reactive power energy | 0.1%RG |
Power Pulse Output | |
Power pulse type | active pulse, reactive pulse |
Active power pulse output | 5V, 10mA |
Power Pulse Input | |
Energy pulse type | support active and reactive pulse, the highest frequency power pulse input is 180K. |
Mechanical parameters | |
Dimensions (W×D×H) (mm) | 325×275×135 |
Weight (kg) | 8 |
Environmental conditions | |
Ambient temperature | -10°C to +50°C |
Relative humidity | 35%-85% |
(1) RG means range, the same as below; (2) RD means the setted harmonic content, harmonic can be a single output, also multiple output. |
Company Details
Business Type:
Manufacturer
Year Established:
2008
Total Annual:
$100,000,000-$150,000,000
Employee Number:
300~350
Ecer Certification:
Active Member
Beijing GFUVE Instrument Transformer Manufacturer Co., Ltd. was established in 2008. It combined design, manufacturing and sales together as one high-tech enterprise. GFUVE Instrument Transformer company mainly produces less than 35kV current transformer and voltage transformer, split core... Beijing GFUVE Instrument Transformer Manufacturer Co., Ltd. was established in 2008. It combined design, manufacturing and sales together as one high-tech enterprise. GFUVE Instrument Transformer company mainly produces less than 35kV current transformer and voltage transformer, split core...
Get in touch with us