Transformer Type | Pad Mounted, Compartmental-Type |
Capacity | 1 MVA (1000 KVA) |
Primary Voltage | 12470GrdY/7200 |
Secondary Voltage | 208Y/120 |
Frequency | 60 Hz |
Cooling Class | KNAN; Self-Cooled |
Impedance (Typical) | 5.75% |
Efficiency | 99.20% |
Brand Name | WINLEY |
Model Number | S-1000/15 |
Certification | UL,cUL,CE,ISO |
Place of Origin | CHINA |
View Detail Information
Explore similar products
167Kva Oil Immersed Single Phase Pad Mounted Transformer 12.47Kv
167kva Single Phase Pole Mounted Dual Winding Transformer Step Down 4160v To
8000KVA/8MVA On-Load Tapping Oil Type Transformer 35KV To 433V
50Kva Single Phase Pad Mounted Transformer Step Down 12.47Kv To 208V
Product Specification
Payment Terms | T/T | Supply Ability | 1000set/month |
Delivery Time | 30days | Packaging Details | Plywood case |
Transformer Type | Pad Mounted, Compartmental-Type | Capacity | 1 MVA (1000 KVA) |
Primary Voltage | 12470GrdY/7200 | Secondary Voltage | 208Y/120 |
Frequency | 60 Hz | Cooling Class | KNAN; Self-Cooled |
Impedance (Typical) | 5.75% | Efficiency | 99.20% |
Brand Name | WINLEY | Model Number | S-1000/15 |
Certification | UL,cUL,CE,ISO | Place of Origin | CHINA |
High Light | Step Down Oil Immersed Transformer ,Pad Mounted Transformer 1000kva ,Oil Immersed Transformer 15kv |
Three Phase Electrical Pad Mounted Step Down Oil Immersed Transformer 1000kva 15kv
summary
The three phase pad mounted transformers we produce have obtained UL certification, with capacities ranging from 30 to 5500kVA and voltages up to 34.5kV. Our products are exported to North America the Philippines and other places in large quantities.
Product Structure
Performance
1) The structure is compact and reasonable, and the volume is small, which is only about one-third of the European-style box change of the same capacity;
2) Fully sealed, fully insulated structure, no need to set up safety barriers, and reliable guarantee for personal safety;
3) There are a variety of power supply schemes for users to choose from, which can adopt terminal power supply and realize ring network or dual power supply;
4) S11 oil-immersed power transformer is adopted, which has low loss, low temperature rise and strong overload capacity;
5) Double fuses (backup protection fuse + plug-in fuse) are used for protection, and the plug-in fuse fuse has the current and temperature dual sensitivity characteristics to ensure the safe and reliable operation of the product;
Main data
Transformer Type | Pad Mounted, Compartmental-Type |
Transformer Configuration | Liquid Filled Pad Mounted |
Transformer Feed Type | Loop Feed |
Phase | Three Phase |
Capacity | 1 MVA (1000 KVA) |
Primary Voltage | 12470GrdY/7200 |
Primary Voltage Class | 15 kV Class |
Primary Phasor | Grounded Wye |
Primary BIL | 95 KV |
Secondary Voltage | 208Y/120 |
Secondary Voltage Class | 1.2 kV Class |
Secondary BIL | 30 KV |
Frequency | 60 Hz |
Temperature Rise | 65°C |
Cooling Class | KNAN; Self-Cooled |
Tap Changer | 5-position Tap Changer |
Impedance (Typical) | 5.75% |
Winding Material | Copper |
Ambient Temperature Rating | 40°C |
Sound Level | 58 dBA |
Elevation Rating | 3300ft (1000 meters) Above Sea Level |
Dimensions | 89''-W x 59''-D x 64''-H |
Weight | 8200 lb |
Ratings | Meets/Exceeds DOE 2016 Efficiency Ratings |
Efficiency % | 99.20% |
No Load Loss (in watts)) | +/- 1,300W |
Full Load Loss (in watts) at 100% | +/- 8,500W |
Standard Features
• 60 Hz operation.
• 65°C average winding rise.
• Radial & loop feed arrangements.
• Dead and live front type of HV terminals.
• HV BIL 45 – 150 kV (Dead Front) 200 kV (Live Front).
• LV BIL 30 – 60 kV.
• Three-point latching of low-voltage door.
• High-voltage door, which can be opened only after
the low-voltage door is opened.
• Rigid steel partition.
• Transformer tank welded from cover to base.
• Permanent nameplate.
• One-inch NPT pipe cap filling provision.
• ANSI tank ground pads.
• One-inch drain valve and sampler.
• Automatic pressure-relief valve (35 SCFM).
• Tap changer with (2) 2.5% full capacity taps above
and below nominal.
• One 10”x18” (or 14”x25”) hand hole in transformer
tank cover.
• Painted olive-green color (Munsell 7GY 3.29/1.5).
• Designed, manufactured and tested in accordancewith the latest ANSI standards
Technical drawings
Specification
Rated Capacity | Loss(w) | Dimension(mm) | Weight(kg) | ||||
No-load Loss(W) | On-load Loss | W | D | H | Oil Weight (L) | Total Weight (KG) | |
45kVA | 160 | 1000 | 1730 | 990 | 1270 | 416 | 950 |
75kVA | 180 | 1250 | 1730 | 990 | 1270 | 435 | 1020 |
150kVA | 280 | 2200 | 1730 | 1245 | 1270 | 473 | 1225 |
300kVA | 480 | 3650 | 1830 | 1295 | 1270 | 605 | 1655 |
500kVA | 680 | 5100 | 2260 | 1345 | 1270 | 720 | 2110 |
750kVA | 980 | 7500 | 2260 | 1448 | 1628 | 1022 | 2950 |
1000kVA | 1150 | 10300 | 2260 | 1500 | 1625 | 1325 | 3720 |
1500kVA | 1640 | 14500 | 2210 | 1470 | 2150 | 1552 | 4672 |
2000kVA | 2160 | 20645 | 2380 | 1600 | 2220 | 1855 | 5670 |
2500kVA | 2680 | 27786 | 3070 | 1650 | 2330 | 2006 | 6580 |
3000kVA | 3300 | 30300 | 3260 | 1850 | 2460 | 2336 | 7500 |
3750kVA | 4125 | 37875 | 4080 | 2060 | 2680 | 2650 | 8450 |
Production process
FAQ
1. Q: Can I have a sample order?
A: Yes, we welcome sample order to test and check quality.
2. Q: What is the lead time?
A: Mass production time 15-25 days.
3. Q: How long is the warranty?
A: 24 monthes from B/L. If there are any accessory problems,just provide the photos of damaged accessory,then we will provide free service. According to the number of products,we will provide easily damaged accessories for free. we also can provide technical support if you need.
4. Q: Is OEM/ODM available?
A: Yes,it is! We are manufacturer with our own R&D team, we can customize products according to customer's drawing or requirements.
Customized services:
a. Customized color and special function.
b. Customized box.
c. Print customer's logo.
d. Your other ideas about product, we can help you design and put them into production. The above customized services must be confirmed before production.
5. Q: How to control the products quality?
A: Our company owns the core technology ,all kinds of products hold CE certificate. We have professional engineers. Workers are strictly required to make products according to the drawings. Each process has technical instructors.The QC supervisors will regularly inspect the production. We will do products performance tests during production, and comprehensive quality tests when the products is completed.
Company Details
Business Type:
Manufacturer,Seller
Year Established:
2007
Total Annual:
$15M-$20M
Employee Number:
50~70
Ecer Certification:
Verified Supplier
WINLEY is located in Xiamen, China. We are specialized in manufacturing all kinds of transformers, voltage stabilizers, voltage regulators, reactors, etc. The products are widely used in industrial machinery, new energy, power generation, power supply, coal, metallurgy, petroleum, chemical, con... WINLEY is located in Xiamen, China. We are specialized in manufacturing all kinds of transformers, voltage stabilizers, voltage regulators, reactors, etc. The products are widely used in industrial machinery, new energy, power generation, power supply, coal, metallurgy, petroleum, chemical, con...
Get in touch with us
Leave a Message, we will call you back quickly!