China factories

China factory - XI'AN BEICHENG ELECTRONICS CO.,LTD

XI'AN BEICHENG ELECTRONICS CO.,LTD

  • China
  • Site Member

Leave a Message

we will call you back quickly!

Submit Requirement
China RTD Calibrator Thermocouple Multifunction Process Calibrator Temperature
China RTD Calibrator Thermocouple Multifunction Process Calibrator Temperature

  1. China RTD Calibrator Thermocouple Multifunction Process Calibrator Temperature
  2. China RTD Calibrator Thermocouple Multifunction Process Calibrator Temperature
  3. China RTD Calibrator Thermocouple Multifunction Process Calibrator Temperature
  4. China RTD Calibrator Thermocouple Multifunction Process Calibrator Temperature
  5. China RTD Calibrator Thermocouple Multifunction Process Calibrator Temperature

RTD Calibrator Thermocouple Multifunction Process Calibrator Temperature

  1. MOQ: 1pcs
  2. Price: USD115/pc
  3. Get Latest Price
Payment Terms T/T, Western Union, L/C, Paypal
Supply Ability 3000pcs available
Delivery Time 5 to 30 days
Packaging Details 10pcs/Carton; Carton Size: 39.5*38.5*26cm; 10KG/carton
Color Blue or Orange and Black
Size 180*90*47mm
Product Name Temperature Source
Model No. VICTOR 02S
Material Plastic, metal, silica gel
Packing Details 10pcs/Carton; Carton Size: 39.5*38.5*26cm
Accuracy 0.05% accuracy
Weight Approx. 900 g (including batteries)
Power supply 2*1.5V AA Alkaline battery
Brand Name VICTOR
Model Number VICTOR 02S
Certification CE
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union, L/C, Paypal Supply Ability 3000pcs available
Delivery Time 5 to 30 days Packaging Details 10pcs/Carton; Carton Size: 39.5*38.5*26cm; 10KG/carton
Color Blue or Orange and Black Size 180*90*47mm
Product Name Temperature Source Model No. VICTOR 02S
Material Plastic, metal, silica gel Packing Details 10pcs/Carton; Carton Size: 39.5*38.5*26cm
Accuracy 0.05% accuracy Weight Approx. 900 g (including batteries)
Power supply 2*1.5V AA Alkaline battery Brand Name VICTOR
Model Number VICTOR 02S Certification CE
Place of Origin CHINA
High Light R Thermocouple Multifunction Process CalibratorK Thermocouple Multifunction Process CalibratorR Thermocouple multifunction calibrator

VICTOR 02SThermocouple Calibrator Imput And Output Source 8 Types Of Thermocouple Measurement (R/S/K/E/J/T/B/N)

 

VC02TEMPERATURE CALIBRATOR

 

Basic characteristics of the product

  • Input measurement characteristics
  • Basic functions

DC voltage DCV, resistance OHM, thermocouple TC, thermal resistance RTD, on/off

  • The maximum measurement accuracy is 0.05% and the measurement display is 5 digits.
  • Measurement rate: 2-3 times/sec.
  • 2W / 3W / 4W measurements are available for OHM and RTD.
  • The measured temperature value and the corresponding temperature signal are displayed on the same screen.
  • Analog output characteristics
  • Basic functions

DC voltage DCV, resistance OHM, thermocouple TC, thermal resistance RTD

  • The maximum output accuracy is 0.05% and the output display is 5 digits.
  • Output settings can be manually increased or decreased by position.
  • H/L settings are available for OHM excitation current.
  • The output temperature value and the corresponding temperature signal are displayed on the same screen.
  • It has a built-in high-precision temperature sensor for high-precision cold-end compensation.

Thermocouple cold-end compensation can be set, including manual compensation, automatic compensation, compensation access disconnection, etc.

  • It has maintenance setup functions, including

Auto power-off, backlight, flashlight, buzzer, etc.

  • Others
  • The segment code is displayed on an LCD with a white backlight.
  • It has a LED flashlight for lighting.
  • It is powered by 3 AA battery cells. The battery compartment door is convenient for battery replacement. Low-battery detection is available.
  • It is small, firm, reliable, suitable for field use, and cheap.
  • User-optional large-suction magnetic sling is provided.

 

II. Basic function and performance of the product (technical index)

 

Analog output function [Used within one year after calibration, 23 ℃± 5 ℃, 20-70% RH, accuracy=± (% set value+% reading)]

Output function Range Output range Resolution Accuracy Remarks

DC voltage

DCV

100mV -10.000mV~110.00mV 0.01mV 0.05%+0.03mV Maximum output current: 0.5mA
1V -0.1000V~1.1000V 0.0001V 0.05%+0.3mV Maximum output current 2mA

Ohm

OHM

400Ω 0~400.0Ω 0.1Ω 0.05%+0.2Ω

The excitation current is ±0.1~±5mA

Maximum output voltage 2V

When the excitation current is ±0.1~0.5mA, additional error of 0.1Ω is added

The accuracy does not include lead resistance

4KΩ 0~4.000KΩ 0.05%+2Ω

Thermocouple

TC

R 0°C~1767°C 1°C

0~100℃

10~1767℃

0~100℃

100~1767℃

1.5℃

1.2℃

1.5℃

1.2℃

Use ITS-90 temperature scale

The accuracy does not include the error of cold junction compensation

The accuracy does not include sensor inaccuracy

The accuracy does not include the influence of thermoelectric potential

R: Platinum Rhodium 13- Platinum

S: Platinum Rhodium 10- Platinum

K: Nickel chromium - nickel silicon

E: Nickel chromium - copper nickel (constantan)

J: Iron - copper nickel (constantan)

T: Copper - nickel (constantan)

N: Nickel chromium silicon nickel silicon

B: Platinum Rhodium 30 - Platinum

A: Tungsten rhenium 5- Tungsten rhenium 20

C: Tungsten rhenium 5- Tungsten rhenium 26

D: Tungsten rhenium 3- Tungsten rhenium 25

S 0°C~1767°C
K -200.0°C~1372.0°C 0.1°C

-200.0~-100.0℃

-100.0~400.0℃

400.0~1200.0℃

1200.0~1372.0℃

0.6℃

0.5℃

0.7℃

0.9℃

E -200.0°C~1000.0°C

-200.0~-100.0℃

-100.0~600.0℃

600.0~1000.0℃

0.6℃

0.5℃

0.4℃

J -200.0°C~1200.0°C

-200.0~-100.0℃

-100.0~800.0℃

800.0~1200.0℃

0.6℃

0.5℃

0.7℃

T -250.0°C~400.0°C -250.0~400.0℃ 0.6℃
N -200.0°C~1300.0°C

-200.0~-100.0℃

-100.0~900.0℃

900.0~1300.0℃

1.0℃

0.7℃

0.8℃

B 600°C~1820°C 1°C

600~800℃

800~1820℃

1.5℃

1.1℃

A 0°C~2500°C 1°C

0~1600℃

1600~2000℃

2000~2500℃

2.0℃

2.2℃

2.4℃

C 0°C~2310°C 1°C

0~1600℃

1600~2000℃

2000~2310℃

2.0℃

2.2℃

2.4℃

D 0°C~2310°C 1°C

0~100℃

100~270℃

270~1200℃

270~2310℃

2.6℃

2.4℃

2.2℃

2.4℃

Thermal resistance

RTD

Pt100

385

-200.0°C~800.0°C 0.1°C

-200.0~0.0℃

0.0~400.0℃

400.0~800.0℃

0.3℃

0.5℃

0.8℃

Use Pt (385) temperature scale

The excitation current is ±0.1~±5mA

Maximum output voltage 2V

When the excitation current is ±0.1~0.5mA, additional error of 0.1Ω is added

The accuracy does not include lead resistance

The accuracy does not include the influence of thermoelectric potential

Support pulse transmitters and PLCs with pulse times as short as 10ms

Pt200

385

-200.0°C~630.0°C  

-200.0~100.0℃

100.0~300.0℃

300.0~630.0℃

0.8℃

0.9℃

1.0℃

Pt500

385

-200.0°C~630.0°C

-200.0~100.0℃

100.0~300.0℃

300.0~630.0℃

0.4℃

0.5℃

0.7℃

Pt1000

385

-200.0°C~630.0°C

-200.0~100.0℃

100.0~300.0℃

300.0~630.0℃

0.2℃

0.5℃

0.7℃

Cu50 -50.0°C~150.0°C 0.6℃
 

 

Other characteristics:

  • Uncertainty includes standard uncertainty, hysteresis, nonlinearity, repeatability, and typical long-term stability over the period mentioned (K = 2).
  • Maximum applied voltage at input end: about 30Vpk; Maximum applied current at input end: about 25mA
  • Load characteristics: capacitive load ≥0.01uF (DCV/OHM/TC/RTD/FREQ); Inductive load ≥ 0.01uF 100uH (DCA)

Output load affects DCmV (0.001% full scale + 1nV)/mA; DCV (0.001% full scale + 1nV)/mA

  • The temperature range of internal temperature compensated sensor RJC is -10 to 50°C. The temperature measurement accuracy at 18 to 28°C is ±0.5°C, and the temperature measurement accuracy at other temperature is ±1°C. Cold end compensation time is 10S/ times.
  • Temperature coefficient: 0.1 × basic accuracy/℃ (temperature range < 18℃ or > 28℃)

 

 

Input measurement function [Used within one year after calibration, 23℃±5℃, 20-70% RH, accuracy =+/-(% set point + reading %)]

Measurement function Range Measurement range Resolution Accuracy Remarks

DC voltage

DCV

100mV -110.00mV~110.00mV 0.01mV 0.05%+0.03mV Input resistance: approximately 1MΩ
1V -1.1000V~1.1000V 0.0001V 0.05%+0.3mV
35V -35.000V~35.000V 0.001V 0.02%+2mV

Resistance

OHM

500Ω 0~550.00Ω 0.01Ω 0.05%+0.2Ω

2W/3W/4W measurement

50 Ω approximately 1mA excitation

5KΩ approximately 0.1mA excitation

Open circuit voltage: approximately 2.5V

The accuracy does not include lead resistance

5KΩ 0~5.5000KΩ 0.0001KΩ 0.05%+2Ω

Thermocouple

TC

R 0°C~1767°C 1°C

0~500℃

500~1767℃

2.5℃

2℃

 

Use ITS-90 temperature scale

The accuracy does not include the error of cold junction compensation

The accuracy does not include sensor inaccuracy

The accuracy does not include the influence of thermoelectric potential

R: Platinum Rhodium 13- Platinum

S: Platinum Rhodium 10- Platinum

K: Nickel chromium - nickel silicon

E: Nickel chromium - copper nickel (constantan)

J: Iron - copper nickel (constantan)

T: Copper - nickel (constantan)

N: Nickel chromium silicon nickel silicon

B: Platinum Rhodium 30 - Platinum

A: Tungsten rhenium 5- Tungsten rhenium 20

C: Tungsten rhenium 5- Tungsten rhenium 26

D: Tungsten rhenium 3- Tungsten rhenium 25

S 0°C~1767°C
K -100.0°~1372.0°C 0.1°C

-100.0~0.0℃

0.0~1372.0℃

1.2℃

0.8℃

E -50.0°C~1000.0°C

-50.0℃~0.0℃

0.0~1000.0℃

0.9℃

1.5℃

J -60.0°C~1200.0°C

-60.0~0.0℃

0.0~1200.0℃

1.0℃

0.7℃

T -100.0°C~400.0°C

-100.0~0.0℃

0.0~400.0℃

1.0℃

0.7℃

N -200.0°~1300.0°C

-200.0~0.0℃

0.0~1300.0℃

1.5℃

0.9℃

B 600°C~1820°C 1°C

600~800℃

800~1000℃

1000~1820℃

2.2℃

1.8℃

1.4℃

A 0°C~2500°C 1°C

0~1600℃

1600~2000℃

2000~2500℃

2.0℃

2.2℃

2.4℃

C 0°C~2310°C 1°C

0~1600℃

1600~2000℃

2000~2310℃

2.0℃

2.2℃

2.4℃

D 0°C~2310°C 1°C

0~100℃

100~270℃

270~1200℃

270~2310℃

2.6℃

2.4℃

2.2℃

2.4℃

Thermal resistance

RTD

(4W)

Pt100

385

-200.0°C~800.0°C 0.1°C

-200.0~0.0℃

0.0~400.0℃

400.0~800.0℃

0.5℃

0.7℃

0.8℃

 

Use Pt (385) temperature scale

2W/3W/4W measurement

50 Ω approximately 1mA excitation

5KΩ approximately 0.1mA excitation

Open circuit voltage: approximately 2.5V

The accuracy does not include the error caused by the mismatch of the 2 W/3 W measurement lead resistance

The accuracy does not include sensor inaccuracy

The accuracy does not include the influence of thermoelectric potential

Pt200

385

-200.0°C~630.0°C

-200.0~100.0℃

100.0~300.0℃

300.0~630.0℃

0.8℃

0.9℃

1.0℃

Pt500

385

-200.0°C~630.0°C

-200.0~100.0℃

100.0~300.0℃

300.0~630.0℃

0.4℃

0.5℃

0.7℃

Pt1000

385

-200.0°C~630.0°C

-200.0~100.0℃

100.0~300.0℃

300.0~630.0℃

0.3℃

0.5℃

0.7℃

Cu50 -50.0°C~150.0°C -50.0~150.0℃ 0.7℃
On/off detection 500Ω ≤50Ω sounding 0.01Ω  

Approximately 1mA excitation

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Trading Company

  • Year Established:

    1980

  • Total Annual:

    4000000-5000000

  • Employee Number:

    200~500

  • Ecer Certification:

    Site Member

VICTOR Instruments is a brand  belongs to Xi'an Beicheng Electronics Co.Ltd. (former Victor Instruments ) which was established in 1980s,VICTOR specializes in producing test instruments and especially digital multimeters. Our products include analog and digital multimeters, clamp-... VICTOR Instruments is a brand  belongs to Xi'an Beicheng Electronics Co.Ltd. (former Victor Instruments ) which was established in 1980s,VICTOR specializes in producing test instruments and especially digital multimeters. Our products include analog and digital multimeters, clamp-...

+ Read More

Get in touch with us

  • Reach Us
  • XI'AN BEICHENG ELECTRONICS CO.,LTD
  • JINGYUAN 7 ROAD, JINGHE INDUSTRIAL PARK, NORTH DISTRICT,XI'AN,CHINA  710200
  • https://www.victormultimeter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement