Payment Terms | T/T, Western Union, L/C, Paypal |
Supply Ability | 3000pcs available |
Delivery Time | 5 to 30 days |
Packaging Details | 10pcs/Carton; Carton Size: 39.5*38.5*26cm; 12KG/carton |
Color | Blue and Black |
Size | 206*97*60mm |
Product Name | Process Multimeter |
Material | Plastic, metal, silica gel |
Packing Details | 6pcs/Carton; Carton Size: 39.5*38.5*26cm |
Accuracy | 0.5% accuracy |
Warranty | 1 year |
Weight | Approx. 600 g (including batteries) |
Brand Name | VICTOR |
Model Number | VICTOR 79A |
Certification | CE |
Place of Origin | CHINA |
View Detail Information
Explore similar products
High Accuracy 10A Analog Digital Multimeter 500V Lcd Display
0.025% Accuracy 55000 Counts VICTOR Digital Multimeter 1000V Fuse Protection
Handheld Smart Auto Range Digital Multimeter Continuity Test Anti Burning
VC9208 Manual Range Digital Multimeter LCD Display With Backlight
Product Specification
Payment Terms | T/T, Western Union, L/C, Paypal | Supply Ability | 3000pcs available |
Delivery Time | 5 to 30 days | Packaging Details | 10pcs/Carton; Carton Size: 39.5*38.5*26cm; 12KG/carton |
Color | Blue and Black | Size | 206*97*60mm |
Product Name | Process Multimeter | Material | Plastic, metal, silica gel |
Packing Details | 6pcs/Carton; Carton Size: 39.5*38.5*26cm | Accuracy | 0.5% accuracy |
Warranty | 1 year | Weight | Approx. 600 g (including batteries) |
Brand Name | VICTOR | Model Number | VICTOR 79A |
Certification | CE | Place of Origin | CHINA |
High Light | Process VICTOR Digital Multimeter ,IP65 VICTOR Digital Multimeter ,IP65 Process Multimeter |
VICTOR 79A Digital Multimeter 2 In 1 4-20mA Signal Output Multimeter Process Signal Source 50MΩ 100KHz RTD RSKEJTNB Cu50 Pt100
Basic feature
Technical index of measurement functions
[adapt to one year after calibration 23℃±5℃,20~70% RH,accuracy=±(% settings + bytes)]
measurement function | range | measurement range | resolution | accuracy | remark |
DC voltage DCV | 50mV | -55.00mV~55.00mV | 0.01mV | 0.1%+4 | Input resistance: about 100MΩ |
500mV | -550.0mV~550.0mV | 0.1mV | 0.1%+4 | ||
5V | -5.500V~5.500V | 0.001V | 0.1%+4 | Input resistance: 10MΩ | |
50V | -55.00V~55.00V | 0.01V | 0.1%+4 | ||
500V | -550.0V~550.0V | 0.1V | 0.1%+4 | ||
1000V | -1000V~1000V | 1V | 0.1%+4 | ||
AC voltage ACV | 5V | 0~5.500V | 0.001V | 0.5%+4 | Input resistance: 10MΩ <100pF 20Hz~1kHz 10%~110% range |
50V | 0~55.00V | 0.01V | 0.5%+4 | ||
500V | 0~550.0V | 0.1V | 0.5%+4 | ||
1000V | 0V~750V | 1V | 0.5%+4 | ||
Ohms OHM | 500Ω | 0~550.0Ω | 0.1Ω | 0.1%+4 | test current: <0.8 mA open-circuit voltage: <2.5V |
5KΩ | 0~5.500KΩ | 0.001KΩ | 0.1%+4 | ||
50KΩ | 0~55.00KΩ | 0.01KΩ | 0.1%+4 | ||
500KΩ | 0~550.0KΩ | 0.1KΩ | 0.1%+4 | ||
5MΩ | 0~5.500 MΩ | 0.001MΩ | 1%+4 | ||
50MΩ | 0~55.00 MΩ | 0.01MΩ | 1%+4 | ||
DC current DCI | 50mA | -55.000mA~55.000mA | 0.001mA | 0.1%+5 | Voltage Drop <1.8 mV/mA response time: ≤1S |
500mA | -500.00mA~500.00mA | 0.01mA | 0.1%+5 | ||
AC current ACI | 50mA | 0.000mA~55.000mA | 0.001mA | 0.5%+10 | Voltage Drop <1.8 mV/mA response time: ≤3S |
500mA | 0.00mA~500.00mA | 0.01mA | 0.5%+10 | ||
frequency FREQ | 10Hz | 0~9.9999Hz | 0.0001Hz | 0.02%+4 | |
100Hz | 0~99.999Hz | 0.001Hz | 0.02%+4 | ||
1000Hz | 0~999.99Hz | 0.01Hz | 0.02%+4 | ||
10kHz | 0~9.9999kHz | 0.0001kHz | 0.02%+4 | ||
100kHz | 0~99.999kHz | 0.001kHz | 0.02%+4 | ||
duty ratio DUTY | 0.1%~99% | 0.1% | 1% | ||
Diode DIODE | 2V | 0.0001V | 1%+10 | ||
Continuity test COUNT | 500Ω | 0.1Ω | ≤100ΩBB | ||
Thermal couple TC | R | -40°C~1760°C | 1°C | 0.5%+3°C(≤100)°C 0.5%+2°C(>100)°C | Employ ITS-90 temperature standard Errors for cold-end compensation is excluded in the accuracy Errors for Thermoelectric potential is excluded in the accuracy |
S | -200°C~1760°C | ||||
B | 400°C~1800°C | ||||
K | -200°C~1350°C | 0.5%+2°C(≤-100)°C 0.5%+1°C(>-100)°C | |||
E | -200°C~700°C | ||||
J | -200°C~950°C | ||||
T | -200°C~400°C | ||||
N | -200°C~1300°C | ||||
Resistance temperature RTD | Cu50 | -50°C~150°C | 1°C | 0.5%+3°C | Employ Pt100-385 temperature standard. Measured current: about 0.8mA. Open circuit voltage: about 2V. Wire resistance is excluded in the accuracy. |
Pt100 | -200°C~850°C | ||||
CAP capacity | 10nF | 0~11.00nF | 0.01nF | 5%+50 | |
100nF | 0~110.0nF | 0.1nF | 5%+5 | ||
1000nF | 0~1100nF | 1nF | 5%+5 | ||
10µF | 0~11.00µF | 0.01uF | 5%+5 | ||
100µF | 0~110.0µF | 0.1uF | 5%+5 | ||
1000µF | 0~1100µF | 1uF | 5%+50 | ||
10mF | 0~11.00mF | 0.01mF | 5%+50 | ||
100mF | 0~110.0mF | 0.1mF | 5%+50 |
Simulate output function [adapt to one year after calibration 23℃±5℃,20~70% RH,accuracy=±(% settings + bytes)]
measurement function | range | Output setting range | resolution | accuracy | remark |
DC voltage DCV | 100mV | -10.00~110.00mV | 10μV | 0.2%+4 | Max output current: 0.5mA |
1000mV | -100.0~1100.0mV | 100μV | 0.2%+4 | Max output current: 2mA | |
10V | -1.000~11.000V | 1mV | 0.2%+4 | Max output current: 5mA | |
DC current DCI | 30mA | 0.000~33.000mA | 0.001mA | 0.2%+4 | 20mA max load 1KΩ 30mA max load 600Ω |
simulate transmitter SIMULATE | -30mA | 0.000~-33.000mA | 0.001mA | ||
Loop power LOOP | 24V | ±10% | Max output current: 35mA | ||
Ohms OHM | 400Ω | 0.0Ω~400.0Ω | 0.1Ω | 0.2%+4 | Simulate current is±0.5~3mA When simulate current is±0.1~0.5mA,add additional 0.1Ω error. wire resistance is excluded in the accuracy |
Thermal couple TC | R | 0°C~1767°C | 1°C | 0.2%+3°C(≤100℃) 0.2%+2°C(>100℃) | Employ ITS-90 temperature standard. Errors for cold-end compensation is excluded in the accuracy.
|
S | 0°C~1767°C | ||||
B | 600°C~1820°C | ||||
K | -200.0°C~1372.0°C | 0.1°C | 0.2%+2°C(≤-100℃) 0.2%+1°C(>-100℃) | ||
E | -200.0°C~1000.0°C | ||||
J | -200.0°C~1200.0°C | ||||
T | -250.0°C~400.0°C | ||||
N | -200.0°C~1300.0°C | ||||
Resistance temperature RTD | PT100 | -0200.0~0850.0 | 0.1°C | 0.2%+0.6°C | Employ Pt100-385 temperature standard ±1mA simulate current wire resistance is excluded in the accuracy |
Cu50 | -050.0~150.0 | ||||
Frequency FREQ | 100Hz | 1.0Hz~110.0Hz | 0.1Hz | 0.2%+2 | square wave 50% duty ratio 1~11Vp-p |
1KHz | 0.100KHz~1.100KHz | 1Hz | 0.2%+2 | ||
10KHz | 1.0KHz~11.0KHz | 0.1KHz | 0.2%+2 |
Technical Data
Project | VICTOR 79 | VICTOR 79A | ||
Measurement | DC voltage | Range | ±400V | ±1000V |
The highest resolution | 0.01mV | 0.01mV | ||
Basic accuracy | 0.2% | 0.1% | ||
AC voltage | Range | 400V | 750V | |
The highest resolution | 0.1mV | 0.1mV | ||
Basic accuracy | 0.5% | 0.5% | ||
Resistance | Range | 40MΩ | 50MΩ | |
The highest resolution | 0.1Ω | 0.1Ω | ||
Basic accuracy | 0.2% | 0.1% | ||
DC current | Range | ±400mA | ±500mA | |
The highest resolution | 10uA | 1uA | ||
Basic accuracy | 0.2% | 0.1% | ||
AC current | Range | 400mA | 500mA | |
The highest resolution | 10uA | 1uA | ||
Basic accuracy | 0.5% | 0.5% | ||
Thermocouple | Range | R,S,B,E,K,J,T,N | R,S,B,E,K,J,T,N | |
The highest resolution | 1°C | 1°C | ||
Basic accuracy | 0.5% | 0.5% | ||
RTD | Range | Cu50,Pt100 | Cu50,Pt100 | |
The highest resolution | 1°C | 1°C | ||
Basic accuracy | 0.5% | 0.5% | ||
CAP | Range | N/A | 100mF | |
The highest resolution | 0.01nF | |||
Basic accuracy | 5% | |||
Frequency | 10Hz~100kHz | 10Hz~100kHz | ||
Diode test | √ | √ | ||
Continuity beeper | √ | √ | ||
Data hold | √ | √ | ||
Relative value measurement | √ | √ | ||
Source | DC voltage | Range | -10.00mV~110.00mV -0.5000V~5.5000V | -10.00mV~110.00mV -100.0mV~1100.0mV -1.000V~11.00V |
Resolution | 0.01mV,0.1mV | 0.001mV,0.01mV,0.1mV | ||
Basic accuracy | 0.2% | 0.2% | ||
Resistance | Range | 0~400.0Ω | 0~400.0Ω | |
Resolution | 0.1Ω | 0.1Ω | ||
Basic accuracy | 0.2% | 0.2% | ||
DC current | Range | 22mA | 33mA | |
Resolution | 0.001mA | 0.001mA | ||
Basic accuracy | 0.2% | 0.2% | ||
Simulating transmitter | √ | √ | ||
25%,100%Step output | √ | √ | ||
Automatic ramp | √ | √ | ||
Automatic step | √ | √ | ||
Display current and % of span | √ | √ | ||
Loop power | 15V | 24V | ||
Frequency | 1.0Hz~11.0kHz | 1.0Hz~11.0kHz | ||
Thermocouple | R,S,B,E,K,J,T,N | R,S,B,E,K,J,T,N | ||
RTD | Cu50,Pt100 | Cu50,Pt100 | ||
Loop detection | The 24V loop power supply and measuring the current | N/A | √ | |
Built in 250 Ω HART loop resistance | N/A | √ | ||
Power Supply | 4×1.5V AAA Alkaline battery | 4×1.5V AA Alkaline battery | ||
Auto Power-off | √ | √ | ||
Backlight | √ | √ | ||
Safety | CAT Ⅲ 600V, Pollution degree 2 | CAT Ⅲ 600V, Pollution degree 2 | ||
Size | 205×95×42 | 206×97×60 | ||
Weight | About 500g | About 500g | ||
Accessories | Test line, manual,fuse | Test line, manual,fuse | ||
Standard Quantity Per Carton | 10pcs | 10pcs | ||
Standard Carton Measurement | 395mm*385mm*260mm | 395mm*385mm*260mm | ||
Standard Carton Cross Weight | 10.2Kg | 12Kg |
Company Details
Business Type:
Manufacturer,Exporter,Trading Company
Year Established:
1980
Total Annual:
4000000-5000000
Employee Number:
200~500
Ecer Certification:
Site Member
VICTOR Instruments is a brand belongs to Xi'an Beicheng Electronics Co.Ltd. (former Victor Instruments ) which was established in 1980s,VICTOR specializes in producing test instruments and especially digital multimeters. Our products include analog and digital multimeters, clamp-... VICTOR Instruments is a brand belongs to Xi'an Beicheng Electronics Co.Ltd. (former Victor Instruments ) which was established in 1980s,VICTOR specializes in producing test instruments and especially digital multimeters. Our products include analog and digital multimeters, clamp-...
Get in touch with us
Leave a Message, we will call you back quickly!