Model NO. | All Aluminum Alloy Conductor AAAC |
Material Shape | Round Wire |
Range of Application | Overhead |
Brand | Ume |
Third Party Inspection | Accepted |
Sample | Free |
Color | Customer Specified |
OEM | Accepted |
Transport Package | Drum |
Specification | All Aluminum Alloy Conductor AAAC |
Trademark | UME |
Origin | China |
HS Code | 7614900000 |
Supply Ability | 500, 000km Per Month |
Type | Bare |
Conductor Type | Stranded |
Application | Overhead |
Conductor Material | Aluminum Alloy |
Sheath Material | None |
Insulation Material | Bare |
Samples | US$ 1/Piece 1 Piece(Min.Order) | Request Samp |
Certification | ISO9001, CE, SGS TUV |
View Detail Information
Explore similar products
Round Wire Overhead Transmission Cable All Aluminum Alloy Conductor Steel
Overhead Transmission Line AACSR Round Wire Aluminum Alloy Conductor Steel
AAAC Conductor 1120 for Distribution Line All Aluminum Alloy Conductor up to
Overhead Distribution Line AAAC 6201 All Aluminum Alloy Conductor Sheath
Product Specification
Model NO. | All Aluminum Alloy Conductor AAAC | Material Shape | Round Wire |
Range of Application | Overhead | Brand | Ume |
Third Party Inspection | Accepted | Sample | Free |
Color | Customer Specified | OEM | Accepted |
Transport Package | Drum | Specification | All Aluminum Alloy Conductor AAAC |
Trademark | UME | Origin | China |
HS Code | 7614900000 | Supply Ability | 500, 000km Per Month |
Type | Bare | Conductor Type | Stranded |
Application | Overhead | Conductor Material | Aluminum Alloy |
Sheath Material | None | Insulation Material | Bare |
Samples | US$ 1/Piece 1 Piece(Min.Order) | Request Samp | Certification | ISO9001, CE, SGS TUV |
High Light | AAAC stranded conductor transmission lines ,bare conductor electric transmission lines ,AAAC conductor with third party inspection |
ONE-STOP SOLUTIONS FOR WIRES&CABLES - HENAN UME CABLE CO., LTD
Over 30 years of Wires and Cables manufacture experience and Export to over 50 countries.
1. Applications
All Aluminum Alloy Conductors, characterized by light weight and high strength is used in overhead electric power transmission and distribution lines with various grade voltages.
2. Construction
Aluminum alloy wires are concenreically stranded.
3. Standards
IEC61089, BS3242, DIN48201, ASTM B399, BS EN50183, GB/T 1179-2008
Code Name | Nominal Area | No. / Dia. of Wire | Approx. Overall Dia. | Approx. Weight | Calculated Breaking Load | Max. DC Resistance at 20° C |
mm2 | No./mm | mm | kg/km | kN | Ω/km | |
16 | 18.4 | 7/1.83 | 5.49 | 50.4 | 5.4 | 1.7896 |
25 | 28.8 | 7/2.29 | 6.87 | 78.7 | 8.5 | 1.1453 |
40 | 46 | 7/2.89 | 8.67 | 125.9 | 13.6 | 0.7158 |
63 | 72.5 | 7/3.63 | 10.89 | 198.3 | 21.4 | 0.4545 |
100 | 115 | 19/2.78 | 13.90 | 316.3 | 34.0 | 0.2877 |
125 | 144 | 19/3.10 | 15.50 | 395.4 | 42.4 | 0.2302 |
160 | 184 | 19/3.51 | 17.55 | 506.1 | 54.3 | 0.1798 |
200 | 230 | 19/3.93 | 19.65 | 632.7 | 67.9 | 0.1439 |
250 | 288 | 19/4.39 | 21.95 | 790.8 | 84.9 | 0.1151 |
315 | 363 | 37/3.53 | 24.71 | 998.9 | 107.0 | 0.0916 |
400 | 460 | 37/3.98 | 27.86 | 1268.4 | 135.8 | 0.0721 |
450 | 518 | 37/4.22 | 29.54 | 1426.9 | 152.8 | 0.0641 |
500 | 575 | 37/4.45 | 31.15 | 1585.5 | 169.8 | 0.0577 |
560 | 645 | 61/3.67 | 33.03 | 1778.4 | 190.1 | 0.0516 |
630 | 725 | 61/3.89 | 35.01 | 2000.7 | 213.9 | 0.0458 |
710 | 817 | 61/4.13 | 37.17 | 2254.8 | 241.1 | 0.0407 |
800 | 921 | 61/4.38 | 39.42 | 2540.6 | 271.6 | 0.0361 |
900 | 1036 | 91/3.81 | 41.91 | 2861.1 | 305.6 | 0.0321 |
1000 | 1151 | 91/4.01 | 44.11 | 3179.0 | 339.5 | 0.0289 |
1120 | 1289 | 91/4.25 | 46.75 | 3560.5 | 380.3 | 0.0258 |
1250 | 1439 | 91/4.49 | 49.39 | 3973.7 | 424.4 | 0.0231 |
Nominal Area | Actual Area | No. / Dia. of Wire | Approx. Overall Dia. | Approx. Weight | Calculated Breaking Load | Max. DC Resistance at 20° C |
mm2 | mm2 | No./mm | mm | kg/km | kN | Ω/km |
16 | 15.9 | 7/1.70 | 5.1 | 43 | 4.4 | 2.0742 |
25 | 24.3 | 7/2.10 | 6.3 | 66 | 6.8 | 1.3593 |
35 | 34.4 | 7/2.50 | 7.5 | 94 | 9.6 | 0.9591 |
50 | 49.5 | 7/3.00 | 9.0 | 135 | 13.8 | 0.6660 |
50 | 48.4 | 19/1.80 | 9.0 | 133 | 13.5 | 0.6849 |
70 | 65.8 | 19/2.10 | 10.5 | 181 | 18.4 | 0.5032 |
95 | 93.3 | 19/2.50 | 12.5 | 256 | 26.1 | 0.3551 |
120 | 117.0 | 19/2.80 | 14.0 | 322 | 32.7 | 0.2831 |
150 | 147.1 | 37/2.25 | 15.8 | 406 | 41.1 | 0.2256 |
185 | 181.6 | 37/2.50 | 17.5 | 500 | 50.7 | 0.1828 |
240 | 242.5 | 61/2.25 | 20.3 | 670 | 67.7 | 0.1371 |
300 | 299.4 | 61/2.50 | 22.5 | 827 | 83.6 | 0.1110 |
400 | 400.1 | 61/2.89 | 26.0 | 1104 | 111.8 | 0.0831 |
500 | 499.8 | 61/3.23 | 29.1 | 1379 | 139.6 | 0.0665 |
625 | 626.2 | 91/2.96 | 32.6 | 1732 | 174.9 | 0.0531 |
800 | 802.1 | 91/3.35 | 36.9 | 2218 | 224.0 | 0.0415 |
1000 | 999.7 | 91/3.74 | 41.1 | 2767 | 279.2 | 0.0333 |
Code Name | Total Area | 1350 Grade Equivalent | No. / Dia. of Wire | Approx. Overall Dia. | Approx. Weight | Calculated Breaking Load | Max. DC Resistance at 20° C | |
AWG or MCM | mm2 | AWG or MCM | No./mm | mm | kg/km | kN | Ω/km | |
Akron | 30.6 | 15.5 | 6 | 7/1.68 | 5.04 | 43 | 4.9 | 2.1588 |
Alton | 48.7 | 24.7 | 4 | 7/2.12 | 6.36 | 68 | 7.8 | 1.3557 |
Ames | 77.5 | 39.2 | 2 | 7/2.67 | 8.01 | 108 | 12.4 | 0.8547 |
Azusa | 123.3 | 62.4 | 1 | 7/3.37 | 10.11 | 171 | 18.9 | 0.5365 |
Anaheim | 155.4 | 78.6 | 2/0 | 7/3.78 | 11.34 | 216 | 23.8 | 0.4264 |
Amherst | 195.7 | 99.3 | 3/0 | 7/4.25 | 12.75 | 272 | 30.0 | 0.3373 |
Alliance | 246.9 | 125.1 | 4/0 | 7/4.77 | 14.31 | 343 | 37.8 | 0.2678 |
Butte | 312.8 | 158.6 | 266.8 | 19/3.26 | 16.30 | 435 | 46.5 | 0.2112 |
Canton | 394.5 | 199.9 | 336.4 | 19/3.66 | 18.30 | 548 | 58.6 | 0.1676 |
Cairo | 465.4 | 236.4 | 397.5 | 19/3.98 | 19.90 | 649 | 69.3 | 0.1417 |
Darien | 559.5 | 283.6 | 477 | 19/4.36 | 21.80 | 778 | 83.1 | 0.1181 |
Elgin | 652.6 | 331.0 | 556.5 | 19/4.71 | 23.55 | 908 | 97.0 | 0.1012 |
Flint | 740.8 | 374.5 | 636 | 19/3.59 | 25.13 | 1028 | 107.4 | 0.0894 |
Greeley | 927.2 | 469.6 | 795 | 19/4.02 | 28.14 | 1289 | 134.6 | 0.0713 |
Nominal Area | Actual Area | No. / Dia. of Wire | Approx. Overall Dia. | Approx. Weight | Calculated Breaking Load | Max. DC Resistance at 20° C |
mm2 | mm2 | No./mm | mm | kg/km | kN | Ω/km |
10 | 10.02 | 7/1.35 | 4.05 | 27.4 | 3.26 | 3.3205 |
16 | 16.08 | 7/1.71 | 5.13 | 44.0 | 5.22 | 2.0695 |
25 | 24.94 | 7/2.13 | 6.39 | 68.2 | 8.11 | 1.3339 |
35 | 34.91 | 7/2.52 | 7.56 | 95.5 | 11.35 | 0.9529 |
50 | 50.14 | 7/3.02 | 9.06 | 137.2 | 16.30 | 0.6635 |
70 | 70.07 | 7/3.57 | 10.7 | 191.7 | 22.07 | 0.4748 |
95 | 95.14 | 7/4.16 | 12.5 | 261.5 | 29.97 | 0.3514 |
150 | 149.96 | 19/3.17 | 15.9 | 412.2 | 48.74 | 0.2229 |
210 | 209.85 | 19/3.75 | 18.8 | 576.8 | 66.10 | 0.1593 |
240 | 239.96 | 19/4.01 | 20.1 | 661.1 | 75.59 | 0.1397 |
300 | 299.43 | 37/3.21 | 22.5 | 825.0 | 97.32 | 0.1119 |
400 | 399.98 | 37/3.71 | 26.0 | 1102.0 | 125.99 | 0.0838 |
500 | 500.48 | 37/4.15 | 29.1 | 1380.9 | 157.65 | 0.0671 |
630 | 631.30 | 61/3.63 | 32.7 | 1741.8 | 198.86 | 0.0532 |
800 | 801.43 | 61/4.09 | 36.8 | 2211.3 | 252.45 | 0.0419 |
1000 | 1000.58 | 61/4.57 | 41.1 | 2760.7 | 315.18 | 0.0335 |
HENAN UME CABLE CO., LTD has a strict quality control policy in every step from the order to After-sales service!
Production:
Q1: Are you a manufacturer?
Yes, we are the manufacturer.
Q2: What are your main products?
Our products range as follows:
1. Electrical wire/PVC Building Wires.
2. PVC/XLPE insulated Power Cables up to 110kv.
3. Overhead Aerial Bundle Cable/ABC Cables.
4. Bare Conductors, like AAC, AAAC, ACSR, ACAR, ASCR/AW, and so on.
5. Steel wire/strand-like EHS, GSW and ACS(Aluminum Clad Steel), CCS(Copper Clad Steel).
6. Rubber Cables, Mining Cables, Welding Cable, and Control Cables.
7. Concentric Cables with Copper/Aluminum/Aluminum Alloy 8000s' Conductor.
Q3: Do you provide samples? Is it free or extra?
Yes, we could offer the samples for free
Q4: Is the quality of your products guaranteed?
We have passed ISO9001, ISO14001, ISO45001, and all our products have CE certificates.
Q5: Which markets do you involve mainly in?
Our products have been exported mainly to Africa, the Middle East, Southeast Asia, South America, Central America, North America, Europe, Australia, etc.
Q6: What is your payment term?
T/T or L/C
Q7: What about the delivery time?
Generally, it is 3-7days if the goods are in stock. Or it is 7-30days if the goods are not in stock, it is according to quantity.
Company Details
Business Type:
Manufacturer
Year Established:
1994
Total Annual:
10000000-50000000
Employee Number:
150~200
Ecer Certification:
Verified Supplier
UME CABLE is one of the leading companies in the production and distribution of cables and wires in China. As a manufacturer, we have been supplied quality products to more than 50 countries. Our mission is to offer our customers best quality cable and wire products with most competitive price, to e... UME CABLE is one of the leading companies in the production and distribution of cables and wires in China. As a manufacturer, we have been supplied quality products to more than 50 countries. Our mission is to offer our customers best quality cable and wire products with most competitive price, to e...
Get in touch with us
Leave a Message, we will call you back quickly!