Payment Terms | L/C, , T/T, Western Union, MoneyGram |
Supply Ability | 1 set per month |
Delivery Time | 45 Days |
Packaging Details | Plywood |
Applied Standard | IEC 62196-1: 2020 |
Applied Figure | Fig A 109, C 109, D 109 |
Output Current | 500A or 1000A |
Output Voltage | Max. DC5V |
Test Current Stability | ± (1% set value + 5 words) |
Current Display Accuracy | ± (0.5% reading + 0.5% range) |
Temperature Measurement Points | 16 channels |
Temperature Measuring Range | 0~260℃ |
Brand Name | Sinuo |
Model Number | SN1106-500A/SN1106-1000A |
Certification | Calibration Certificate (Cost Additional) |
Place of Origin | China |
View Detail Information
Explore similar products
400A 8 Channels Vehicle Testing Equipment Electric Car Vehicle Connectors
Automotive Plugs Vehicle Connectors Cable Anchorage Pull Force and Torque Test
Electric Car Accessories Mechanical Strength 1~6J Energy Pendulum Impact test
Single Station Vehicle Testing Equipment Non - Rewireable Accessories Mechanical
Product Specification
Payment Terms | L/C, , T/T, Western Union, MoneyGram | Supply Ability | 1 set per month |
Delivery Time | 45 Days | Packaging Details | Plywood |
Applied Standard | IEC 62196-1: 2020 | Applied Figure | Fig A 109, C 109, D 109 |
Output Current | 500A or 1000A | Output Voltage | Max. DC5V |
Test Current Stability | ± (1% set value + 5 words) | Current Display Accuracy | ± (0.5% reading + 0.5% range) |
Temperature Measurement Points | 16 channels | Temperature Measuring Range | 0~260℃ |
Brand Name | Sinuo | Model Number | SN1106-500A/SN1106-1000A |
Certification | Calibration Certificate (Cost Additional) | Place of Origin | China |
High Light | 1000A Programmable Temperature Rising Test System ,IEC 62196-1 Temperature Rising Test System |
IEC 62196-3-1 Programmable Temperature Rising Test System 1000A
Product overview:
This temperature rising test system meets the test requirements of IEC 62196-1: 2020 clause 24, IEC 60309-1: 2012 clause 22, , IEC60309, IEC60998, IEC60669, IEC61058, IEC60439EC60309, IEC60998, IEC60669, IEC61058, IEC60439, etc. It can be used to assess the surface heating conditions of electrical accessories when electrical accessories are connected to the load current, and whether the electrode temperature rise meets the requirements of the standard.
Technical parameters:
1. Computer program control to set DC current source:
Maximum output voltage: DC5V
Output constant and adjustable test current: DC1~50~500A two gears continuously selectable or DC 10~1000.0A can be customized
Test current stability: ± (1% set value + 5 words), response time 1S
Current display accuracy: ± (0.5% reading + 0.5% range)
Impedance voltage display accuracy: ± (0.3% reading + 5 words)
2. Working mode: continuous mode, on-off mode, automatic temperature control mode
Continuous on-off mode:
Continuous mode test time: 0.01~99.99 hours
Power-on/power-off time in on-off mode: 0.01~99.99 hours
On-off times: 1~9999 times, the machine will stop automatically when the times are reached
Current setting: computer program control setting
3. Automatic temperature control mode: you can set a stable temperature and automatically find the appropriate current value
Automatically obtain the current result that requires the temperature rise value
Temperature measurement:
Multi-channel temperature tester
Measuring range | 0~260℃, accuracy 0.3% of reading+1℃; resolution: 0.1℃ |
Temperature measurement points | 16 channels (including 1 point to measure the ambient temperature) |
Temperature scanning speed | 1~255 seconds for all channels |
Temperature data recording | Completed by computer, equipped with computer test software |
Temperature measuring thermocouple | American Ω company J type 30AWG filament thermocouple, length 2 meters, a total of 16 pieces |
The temperature probe | It can be charged with AC300V for testing without damaging the instrument |
Thermocouple accuracy | Class I |
Thermocouple test temperature range | -50~260℃ |
Temperature data recording | It is automatically completed by the computer, equipped with computer testing softwre, and can export Excel reports. |
Computer Configuration:
CPU1.8G, 4G memory, 128G hard disk, windows7 operating system and OFFICE processing software
With RS232 communication interface
Automatically record the temperature change curve, can query, print, and export data
Software function:
A. Different working modes can be set: continuous mode, on-off mode, temperature control mode
B. Current program control settings
C. Automatically record data and draw curves: temperature rise-time curve, current-time curve, temperature rise-current curve, data export and other functions
Company Details
Business Type:
Manufacturer
Total Annual:
800000-1500000
Employee Number:
30~50
Ecer Certification:
Verified Supplier
Sinuo is an innovation manufacturing company, specializing in the research and development and sales of laboratory construction and testing equipment for electrical appliances (covering the construction of energy efficiency and performance laboratories, as well as supplementary waterproof testing la... Sinuo is an innovation manufacturing company, specializing in the research and development and sales of laboratory construction and testing equipment for electrical appliances (covering the construction of energy efficiency and performance laboratories, as well as supplementary waterproof testing la...