Payment Terms | T/T |
Supply Ability | 100pcs per month |
Delivery Time | on request |
Packaging Details | standard carton packing |
Degree of protection | IP68 |
Ambient temperature | -40 ... 100 °C (-40 ... 212 °F) |
Dimensions | Length 34mm Diameter 12mm |
Switching function | Normally closed (NC) |
Safety Integrity Level (SIL) | SIL 3 |
Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 |
Brand Name | P+F |
Model Number | NJ2-12GK-SN |
Certification | IECEx\ ATEX \UL |
Place of Origin | Germany |
View Detail Information
Explore similar products
P+F KFD2-SR2-Ex1.W Switch Amplifier SIL 2 35mA 10Hz
P+F LFL2-BK-U-PUR5-EMS Float Switch 250VAC IP68
P+F RL28-8-H-2000-IR Background Suppression Sensor 880nm IP67
P+F Z787 Zener Barrier 50mA DC Positive Polarity
Product Specification
Payment Terms | T/T | Supply Ability | 100pcs per month |
Delivery Time | on request | Packaging Details | standard carton packing |
Degree of protection | IP68 | Ambient temperature | -40 ... 100 °C (-40 ... 212 °F) |
Dimensions | Length 34mm Diameter 12mm | Switching function | Normally closed (NC) |
Safety Integrity Level (SIL) | SIL 3 | Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 |
Brand Name | P+F | Model Number | NJ2-12GK-SN |
Certification | IECEx\ ATEX \UL | Place of Origin | Germany |
High Light | 34mm IP68 Inductive Sensor ,SIL 3 p&f sensors ,p&f sensors NJ2-12GK-SN |
Suitable for 2:1 technology, Switching function: Normally closed (NC), Output type: NAMUR with safety function, Installation: flush, Output type: 2-wire, Thread mold: M12, Construction type: Cylindrical, thread, Series: Cylindrical type, Safety Integrity Level (SIL): SIL 3, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0092X, Equipment protection level Gb: IECEx PTB 11.0092X, Equipment protection level Gc (ec): IECEx TUR 21.0017X, Equipment protection level Da: IECEx PTB 11.0092X
Technical Data
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR with safety function | |
Rated operating distance | 2 mm | |
Installation | flush | |
Assured operating distance | 0 ... 1.62 mm | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.3 | |
Reduction factor r304 | 0.85 | |
Safety Integrity Level (SIL) | up to SIL3 acc. to IEC 61508 Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from P+F, such as KFD2-SH-EX1. | |
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 kΩ) | |
Switching frequency | 0 ... 2000 Hz | |
Suitable for 2:1 technology | yes , with reverse polarity protection diode | |
Current consumption |
| |
| Measuring plate not detected | ≥ 3 mA |
| Measuring plate detected | ≤ 1 mA |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 3 | |
MTTFd | 10660 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity |
| |
| NAMUR | EN 60947-5-6:2000 |
| Standards | EN 60947-5-2:2007 |
Approvals and certificates | ||
IECEx approval |
| |
| Equipment protection level Ga | IECEx PTB 11.0092X |
| Equipment protection level Gb | IECEx PTB 11.0092X |
| Equipment protection level Gc (ec) | IECEx TUR 21.0017X |
| Equipment protection level Da | IECEx PTB 11.0092X |
| Equipment protection level Dc (tc) | IECEx TUR 21.0018X |
| Equipment protection level Mb | IECEx PTB 11.0092X |
ATEX approval |
| |
| Equipment protection level Ga | PTB 00 ATEX 2049 X |
| Equipment protection level Gb | PTB 00 ATEX 2049 X |
| Equipment protection level Gc (ec) | TÜV 20 ATEX 8523 X |
| Equipment protection level Da | PTB 00 ATEX 2049 X |
| Equipment protection level Dc (tc) | TÜV 20 ATEX 8524 X |
UL approval | cULus Listed, General Purpose | |
| Ordinary Location | E87056 |
| Hazardous Location | E501628 |
| Control drawing | 116-0454 |
CCC approval |
| |
| Hazardous Location | 2020322315002308 |
NEPSI approval |
| |
| NEPSI certificate | GYJ16.1392X |
TIIS approval | on request | |
Ambient conditions | ||
Ambient temperature | -40 ... 100 °C (-40 ... 212 °F) | |
Mechanical specifications | ||
Connection type | cable | |
Housing material | Crastin (PBT), black | |
Sensing face | Crastin (PBT), black | |
Degree of protection | IP68 | |
Cable |
| |
| Cable diameter | 4.8 mm ± 0.2 mm |
| Bending radius | > 10 x cable diameter |
| Material | silicone |
| Core cross section | 0.34 mm2 |
| Length | 2 m |
Dimensions |
| |
| Length | 34 mm |
| Diameter | 12 mm |
General information | ||
Use in the hazardous area | see instruction manuals |
Related Part Number:
KFU8-UFT |
K-HM26-2M-261533 |
NBB15-U1-E2 |
NBB1,5-5GM25-E2 |
NBB1,5-5GM25-E2-V3 |
NBB1,5-F79-E0 |
NBB1,5-F79-E2 |
NBB15-U1-Z2 |
NBB5-18GM50-E2-V1 |
NBB15-30GM30-E2-V1 |
NBB15-30GM50-A2-V1 |
NBB15-30GM50-E2 |
NBB15-30GM50-E2-M |
NBB15-30GM50-E2-V1 |
NBB15-30GM50-E2-V1-M |
NBB8-18GM30-E2 |
NBB8-18GM30-E2-V1 |
NBB8-18GM60-A2-V1 |
NJ4-12GK-SN |
NJ5-18GK-N |
NJ5-18GK-N-150 |
NJ5-18GM-N |
NJ8-18GK-N |
RD0-FB-EX4 |
RD0-TI-Ex8.FF.* |
Z787.F |
Company Details
Business Type:
Trading Company
Year Established:
2010
Total Annual:
5000000-8000000
Employee Number:
100~150
Ecer Certification:
Verified Supplier
.gtr-container { font-family: 'Arial', sans-serif; font-size: 14px !important; line-height: 1.6; color: #333; max-width: 800px; margin: 0 auto; padding: 20px; } .gtr-heading { font-size: 18px !important; font-weight: 600; color: #2a5885; margin-bottom: 1... .gtr-container { font-family: 'Arial', sans-serif; font-size: 14px !important; line-height: 1.6; color: #333; max-width: 800px; margin: 0 auto; padding: 20px; } .gtr-heading { font-size: 18px !important; font-weight: 600; color: #2a5885; margin-bottom: 1...
Get in touch with us
Leave a Message, we will call you back quickly!