Payment Terms | D/A, D/P, L/C, Western Union, T/T, MoneyGram,Paypal |
Supply Ability | 100000 pieces per month |
Delivery Time | 5-7 days |
Packaging Details | Packing in wooden cases or cartons |
Medium | Gas/Steam/Liquid |
Nominal Diameter | 15~300mm |
Flow Range | Gas/steam DN15,DN20:6m/s ~ 70m/s DN25,DN32:4m/s ~ 70m/s DN40~DN300:2m/s ~ 70m/s Liquid 0.3m/s ~ 7m/s |
Accuracy | Working condition flow: ±1.0%RD (gas/steam) Mass flow: ±1.5%RD Medium pressure: ±0.75%FS Medium temperature: ±1.0℃ (±1.0%FS at >100℃) |
Repetitive | ±0.2%RD |
Power | 13.5~42VDC |
Output | 4~20mA;0~5Khz;0~10Khz;RS-485;Bluetooth |
Medium Temperature | -40 ~ 150℃ (normal temperature type) -40 ~ 250℃ (medium temperature) |
Pressure | 1.6Mpa (General) 2.5Mpa / 4.0Mpa (Optional) |
Environment Temperature | -40~85℃ |
Environmental Humidity | 5~100%RH |
Protection Grade | IEC IP65/IP67 |
Explosion-proof Grade | ExdⅡCT3/FM/CSA/ATEX |
Material | Body: 304 or 316L Vortex street sensor: 316L Temperature sensor: 304 Pressure sensor: 316L Converter case: aluminum |
Brand Name | HCATM |
Model Number | GMF603-A |
Certification | ExdIICT3/FM/CSA/ATEX |
Place of Origin | Xi'an |
View Detail Information
Explore similar products
304 Stainless Steel Vortex Flow Meter Low Gas Flow Rate With LCD Display
Liquid Gas Steam Vortex Flow Meter With Large Screen LCD Double Line Display
Vortex High Pressure Flow Meter With Excellent Vibration Resistance
304 Stainless Steel Vortex Air Flow Meter With Excellent Vibration Resistance
Product Specification
Payment Terms | D/A, D/P, L/C, Western Union, T/T, MoneyGram,Paypal | Supply Ability | 100000 pieces per month |
Delivery Time | 5-7 days | Packaging Details | Packing in wooden cases or cartons |
Medium | Gas/Steam/Liquid | Nominal Diameter | 15~300mm |
Flow Range | Gas/steam DN15,DN20:6m/s ~ 70m/s DN25,DN32:4m/s ~ 70m/s DN40~DN300:2m/s ~ 70m/s Liquid 0.3m/s ~ 7m/s | Accuracy | Working condition flow: ±1.0%RD (gas/steam) Mass flow: ±1.5%RD Medium pressure: ±0.75%FS Medium temperature: ±1.0℃ (±1.0%FS at >100℃) |
Repetitive | ±0.2%RD | Power | 13.5~42VDC |
Output | 4~20mA;0~5Khz;0~10Khz;RS-485;Bluetooth | Medium Temperature | -40 ~ 150℃ (normal temperature type) -40 ~ 250℃ (medium temperature) |
Pressure | 1.6Mpa (General) 2.5Mpa / 4.0Mpa (Optional) | Environment Temperature | -40~85℃ |
Environmental Humidity | 5~100%RH | Protection Grade | IEC IP65/IP67 |
Explosion-proof Grade | ExdⅡCT3/FM/CSA/ATEX | Material | Body: 304 or 316L Vortex street sensor: 316L Temperature sensor: 304 Pressure sensor: 316L Converter case: aluminum |
Brand Name | HCATM | Model Number | GMF603-A |
Certification | ExdIICT3/FM/CSA/ATEX | Place of Origin | Xi'an |
High Light | vortex air flow meter ,vortex flow transmitter |
4-20mA HART RS-485 Multi-parameter steam air vortex flow meter
Features
High sensitivity, low gas flow rate up to 2m/s
The range ratio exceeds the traditional vortex street and the measurement flow rate range is wide
Patented double vortex sensor design for excellent vibration resistance
No moving parts, no pressure loss
Built-in temperature and pressure sensor dynamically monitor fluid temperature and pressure
Direct measurement of steam mass flow without external temperature pressure compensation
Fully isolated electrical structure completely filters out external interference
Wide supply voltage input range for a variety of complex power environments
Support temperature and pressure compensation integrated two-wire system 4 ~ 20mA power supply
Large screen LCD double-line display, clear and easy to read
With Modbus and HART@4~20mA Fieldbus interface
Application
Compressed air standard consumption measurement
Steam mass flow and consumption measurement
Natural gas standard flow and consumption measurement
Coal mine gas drainage flow monitoring
Fluid temperature pressure measurement
Technical parameters
Model | GMF603-A |
Medium | Gas/Steam/Liquid |
Nominal Diameter | DN15~300 mm (1/2 ~ 12 inches) |
Flow Range | Gas/Steam: DN15, DN20: 6m/s~70m/s; DN25, DN32: 4m/s~70m/s; DN40 ~ DN300: 2m/s to 70m/s Liquid: 0.3m/s~7m/s |
Accuracy | Working condition flow: ±1.0% RD (gas/steam); Mass flow: ±1.5% RD; Medium pressure: ±0.5% FS Medium temperature: ±1.0 °C (±1.0% FS >100 °C) |
Repeatability | ±0.3RD% |
Output | 4~20mA@HART, RS-485, Bluetooth, Internet of Things |
Power | 13.5 ~ 42VDC |
Medium Temperature | -40~150 ° C (normal temperature type); -40~ 250 ° C (high temperature type) |
Process Pressure | 1.6MPa (universal) 2.5MPa, 4.0MPa (optional) |
Process Temperature | -40~+85°C |
Environment Humidity | 5~100% RH |
Process Connection | Clamp type / flange connection type / clamp connection (sanitary) type |
Protection Level | IEC IP65/IP67 |
Explosion-proof Grade | ExdIICT3/FM/CSA/ATEX |
Material | Body: 304 or 316L Vortex sensor: 316L Temperature sensor: 304 Pressure sensor: 316L Converter housing: aluminum |
Company Details
Business Type:
Manufacturer
Year Established:
2007
Total Annual:
8000000-10000000
Employee Number:
80~120
Ecer Certification:
Active Member
Xi'an Huance Automation Technology Co., Ltd. is located in Xi'an High-tech Development Zone - Free Trade Zone, China, was established in 2007. Huance specializes in the research and development of liquid ultrasonic flowmeter, gas ultrasonic flowmeter, Coriolis mass flowme... Xi'an Huance Automation Technology Co., Ltd. is located in Xi'an High-tech Development Zone - Free Trade Zone, China, was established in 2007. Huance specializes in the research and development of liquid ultrasonic flowmeter, gas ultrasonic flowmeter, Coriolis mass flowme...
Get in touch with us
Leave a Message, we will call you back quickly!