China KF300 Kiln Inlet Online Gas Monitoring Accurate Emission Analysis for Cement
China KF300 Kiln Inlet Online Gas Monitoring Accurate Emission Analysis for Cement

  1. China KF300 Kiln Inlet Online Gas Monitoring Accurate Emission Analysis for Cement
  2. China KF300 Kiln Inlet Online Gas Monitoring Accurate Emission Analysis for Cement
  3. China KF300 Kiln Inlet Online Gas Monitoring Accurate Emission Analysis for Cement

KF300 Kiln Inlet Online Gas Monitoring Accurate Emission Analysis for Cement

  1. MOQ: MOQ 1pc
  2. Price: USD26000
  3. Get Latest Price
Description High-precision kiln inlet gas analyzer for cement plants, ensuring safety, efficiency, and emission compliance.
Stock In stock 100pcs
Payment Terms T/T
Shipping Method Express
Product Name Online gas monitoring system
Measurement Gases Up to 5 types (e.g., CO₂, CO, NOx, SO₂, O₂)
Sampling Method Heated extraction with QT100 probe
Max Flue Gas Temperature 1,200 °C (sampling probe heating 120–180 °C adjustable)
Automation Features Auto sampling, purging, calibration, fault diagnosis, alarms
Output RS232 / RS485 (Modbus), 4–20 mA analog output

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Description High-precision kiln inlet gas analyzer for cement plants, ensuring safety, efficiency, and emission compliance. Stock In stock 100pcs
Payment Terms T/T Shipping Method Express
Product Name Online gas monitoring system Measurement Gases Up to 5 types (e.g., CO₂, CO, NOx, SO₂, O₂)
Sampling Method Heated extraction with QT100 probe Max Flue Gas Temperature 1,200 °C (sampling probe heating 120–180 °C adjustable)
Automation Features Auto sampling, purging, calibration, fault diagnosis, alarms Output RS232 / RS485 (Modbus), 4–20 mA analog output
High Light KF300 Online Gas Monitoring Analysis SystemKiln Inlet Online Gas Monitoring SystemCement Plant Online Gas Monitoring Systemng

KF300 Online Gas Monitoring System

Product Description

The KF300 Kiln Inlet Online Gas Monitoring System from Kelisaike Safety is a high-performance solution designed specifically for the demanding operating conditions of cement plants. Using advanced heated extraction technology and a specialized QT100 sampling probe, it delivers accurate, real-time analysis of key gaseous pollutants such as CO₂, CO, NOx, SO₂, and O₂—directly from the kiln inlet, decomposition furnace, or preheater outlet.

Engineered for extreme environments, the KF300 operates reliably in flue gas temperatures up to 1,200 °C and dust concentrations of 2,000 g/m³, while withstanding corrosive gases such as SO₂. The pretreatment system features imported components to resist water, dust, corrosion, and clogging, ensuring continuous operation with minimal maintenance.

The integrated WT300 multi-gas infrared analyzer supports up to five gas channels with high measurement accuracy, rapid response time (<25s), and versatile data outputs including RS232/RS485 (Modbus) and 4–20 mA analog signals. Combined with the BRG100 heat-tracing sampling pipe, the system maintains sample integrity even in low ambient temperatures or humid conditions.

Automation is at the core of the KF300 design, featuring automatic sampling, purging, calibration, fault self-diagnosis, and alarm functions. This reduces manual intervention, lowers operational costs, and ensures consistent data quality for process optimization, safety assurance, and environmental compliance.

With its robust construction, intelligent control software, and industry-proven sampling technology, the KF300 is the ideal solution for cement producers seeking to improve clinker quality, reduce fuel consumption, and meet strict emission standards—all in one integrated system.

 

Flue Environmental Parameters

Project Indicators
Channel Max 5 measured gases
  Ccnfiguration information includes
  Measuring gas type
  Measurement range
  Measuring error
Response time General: <25s (t90@60L/h Constant flow)
Warm time 3min~30minn @ambient 20℃(accord different detector configuration)

Digital Res. (@zero

 

General:
  -0.01vol% in case of percent range(e.g. 0.001vol% for BMBT O2 channel)
  -0.1 umol/mol in case of umol/mol range
Analog output 4~20mA
Communication Standard RS232, RS485 with modbus protocol
Fuse Fuse current: 3A, Blow characteristic: Fast Acting
Data interface 4-way switch input; 8-way relay output
Communication Interface 1-way RS-232,1-way RS-485(supports Modbus protocol)
Power 220 V AC/50 Hz 100 W

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller

  • Year Established:

    2004

  • Total Annual:

    1300000-2000000

  • Employee Number:

    100~300

  • Ecer Certification:

    Verified Supplier

Nanjing KELISAIKE Safety Equipment Company is one of the largest safety equipment manufacturers, possessing complete product ranges and specifications in the safety equipment industry of mainland China. Founded in 2004, Nanjing KELISAIKE has set three subsidiaries in Beijing, Xi'an, and Xinjiang... Nanjing KELISAIKE Safety Equipment Company is one of the largest safety equipment manufacturers, possessing complete product ranges and specifications in the safety equipment industry of mainland China. Founded in 2004, Nanjing KELISAIKE has set three subsidiaries in Beijing, Xi'an, and Xinjiang...

+ Read More

Get in touch with us

  • Reach Us
  • Nanjing Kelisaike Safety Equipment Co., Ltd.
  • Bldg 12, 2 Qingshuiting West Road, Nanjing, Jiangsu, China, 211102
  • https://www.portable-gasdetector.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement