China factories

China factory - Chongqing Bio Newvision Medical Equipment Ltd.

Chongqing Bio Newvision Medical Equipment Ltd.

  • China,Chongqing ,Chongqing
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China Red Free Digital Fundus Camera Non Dilated Retinal Imaging
China Red Free Digital Fundus Camera Non Dilated Retinal Imaging

  1. China Red Free Digital Fundus Camera Non Dilated Retinal Imaging
  2. China Red Free Digital Fundus Camera Non Dilated Retinal Imaging

Red Free Digital Fundus Camera Non Dilated Retinal Imaging

  1. MOQ: 1
  2. Price: $12,000.00-$13,000.00
  3. Get Latest Price
Payment Terms , T/T
Supply Ability 100
Delivery Time 5 working days
Product name Retina Digital Fundus Camera
Size 380mm(L)x550mm(W)x475mm(H)
Weight 26.5Kg
Field View 50°
Working Distance 35mm
Minimum Pupil ≥3.3mm
Focus Modes Manual/Auto
Feature The Area Of Retinal Degeneration And Bleeding Was Observed
Brand Name SYSEYE
Model Number RetiCam 3100
Certification FDA
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms , T/T Supply Ability 100
Delivery Time 5 working days Product name Retina Digital Fundus Camera
Size 380mm(L)x550mm(W)x475mm(H) Weight 26.5Kg
Field View 50° Working Distance 35mm
Minimum Pupil ≥3.3mm Focus Modes Manual/Auto
Feature The Area Of Retinal Degeneration And Bleeding Was Observed Brand Name SYSEYE
Model Number RetiCam 3100 Certification FDA
Place of Origin China
High Light 35mm Red Free Digital Fundus Camera50 degree 3.3mm Digital Fundus Camera35mm FDA retinal imaging camera

The Area Of Retinal Degeneration And Bleeding Was Observed Digital Fundus Camera

 

Non-dilated Digital Fundus Camera is a product of great revolutionary significance to the medical industry. It can reduce discomfort to patients with extremely low flash intensity, and has ergonomic design and intuitive and simple control, which can provide a faster, more accurate and more comfortable retinal examination process, can effectively monitor and detect diabetic retinopathy, glaucoma and macular degeneration and other diseases. At the same time, all image data can be easily processed, printed, saved and transmitted to remote locations, which is convenient to combine with existing medical imaging system and realize the connection with image archiving and communication system (PACS) and hospital information system (HIS), thus simplifying the overall diagnostic workflow.

 

Digital Fundus Camera RetiCam 3100 can be used to capture the anterior and posterior eye images. It has a field of view of 50 degrees for fundus imaging.

 

Digital Fundus Camera Reticam 3100 is a highly recognized and popular automatic fundus imaging system around the world. Through dual camera imaging, image control and feature recognition, eye XYZ 3D automatic positioning is realized. Through CCD imaging feedback, the exposure is measured, and the exposure intensity is automatically and accurately determined, without the need for a doctor's complex operation. By controlling the focusing step length according to the image resolution, the image definition can be automatically adjusted to obtain a clear and accurate fundus image and help doctors make accurate judgments for patients.

 

 

Acquisition Modes Digital Fundus Camera/mydriatic Anterior photography /Red-free(optional)(FFA)/(FAF)
Field View 50°
Working Distance 35mm
Minimum Pupil ≥3.3mm
Focus Modes Manual/Auto
Alignment Modes Double dots auxiliary
Exposure Manual /Auto
Photography SLR Camera
Image definition 24 Megapixel
Compensation ±25D
Fixation External /Internal (any position available)
DICOM 3.0 Support

 

 

                                    Digital Fundus Camera in the world
Brand TOPCON(NW-400) DRS NEWVISON(RETICAM3100)
operation automatic(one key taking picutre)/manual automatic(one key taking picutre)/manual automatic(one key taking picutre)/manual
Acquisition modes fundus/anterior/? fundus/anterior/red-free filter fundus/anterior/red-free filter/FFA(optional)/FAF(optional)
Filed of view 45 degree 40-45degree 45-50degee
Mosic degee   80 degree 135degree
Minimum pipil size 3.3mm 3.5mm 3.3mm
Resolution above 18megapiexl sensor size:5 megapixel sensor resoultion: 48 pixel/degree above18 megapixel (24 megapixel optional )
Fixation 9 internal + 1 outside fixaiton 7 internal fixation countless fixaiton, any position is available during range + 1 outside fixation
Technology of focus     Dual camrea technology
exposure ligh standard standard new technology, more soft, one patient same eye can take picuture consecutive with almost same performace

 

 

Company Introduction

Focusing on the two major public health problems of adolescent myopia and elderly ophthalmology, our company researches new diagnostic and treatment equipment for ophthalmology, develops low-cost applicable technology products, realizes industrialization, reduces the cost of social medical and health system, and serves the strategic needs of national health.The company always adhere to the "high-tech,new vision" for the enterprise development concept.We have a strong technical force, has been awarded 11 patents, and obtained 13,485 quality system certification.Bio has established an efficient marketing team and a perfect after-sales service system to provide medical equipment with the highest cost performance and meticulous service.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2011

  • Total Annual:

    20000000-30000000

  • Employee Number:

    200~500

  • Ecer Certification:

    Verified Supplier

Chongqing Bio Newvision Medical Equipment Ltd. Focusing on the two major public health problems of adolescent myopia and elderly ophthalmology, our company researches new diagnostic and treatment equipment for ophthalmology, develops low-cost applicable technology products, realizes ind... Chongqing Bio Newvision Medical Equipment Ltd. Focusing on the two major public health problems of adolescent myopia and elderly ophthalmology, our company researches new diagnostic and treatment equipment for ophthalmology, develops low-cost applicable technology products, realizes ind...

+ Read More

Get in touch with us

  • Reach Us
  • Chongqing Bio Newvision Medical Equipment Ltd.
  • 2nd floor of building #5, 27 Fengsheng Road, Jinfeng Town,High-Tech Industrial Development Zone, 401329 Chongqing, People's Republic of China
  • https://www.perimetrymachine.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement