Payment Terms | T/T,Western Union,Paypal |
Delivery Time | 3-5 working days |
Packaging Details | Carton |
Product Name | power management board |
Model | CM1200B_POWER_B CEP3CCB 00377 |
Condition | Used-good |
MOQ | 1 Piece |
Type | Spart parts |
Color | Green |
Payment terms | TT/Paypal/Western Union |
Delivery Motheds | DHL/Fedex |
Warranty | 90 Days |
More Details | Contact CWT Technology HK Limited |
Brand Name | Comen |
Model Number | CM1200B |
View Detail Information
Explore similar products
Edan SE-1200 Express ECG/EKG Machine Display (800*600 Multicolor LCD Screen)
SCHILLER AT-101 ECG Machine Top Cover White Spare Parts for ECG Machine with
Mortara ELI 250 ECG Machine FUSE Used In Good Working Black Color ECG Monitor
Pagewriter TC10 Long 10 Lead Patient Cable AHA 3.8 M 12.5´ Long AAMI 98980318495
Product Specification
Payment Terms | T/T,Western Union,Paypal | Delivery Time | 3-5 working days |
Packaging Details | Carton | Product Name | power management board |
Model | CM1200B_POWER_B CEP3CCB 00377 | Condition | Used-good |
MOQ | 1 Piece | Type | Spart parts |
Color | Green | Payment terms | TT/Paypal/Western Union |
Delivery Motheds | DHL/Fedex | Warranty | 90 Days |
More Details | Contact CWT Technology HK Limited | Brand Name | Comen |
Model Number | CM1200B | ||
High Light | CM1200B_POWER_B power management board ,00377 power management board ,CEP3CCB power management board |
Used-good ECG parts Comen CM1200B ECG power management board CM1200B_POWER_B CEP3CCB 00377
■ Product Describe
The Comen CM1200B ECG Power Management Board is a genuine accessory for the CM1200B ECG, a key component tailored to the complex power requirements of the device. It precisely converts, regulates, and distributes power from an external power source or internal battery, ensuring a stable and optimal power supply to each functional module, ensuring reliable operation and accurate ECG monitoring.
This accessory is only compatible with the Comen CM1200B ECG, a multi-lead, simultaneous ECG device widely used in medical institutions at all levels. It can be used in outpatient clinics, emergency rooms, and wards to quickly and accurately monitor cardiac function. It supports 12-lead simultaneous ECG signal acquisition and features automatic analysis, quickly identifying common arrhythmias and annotating the results on the printed ECG report, assisting doctors in diagnosis and improving efficiency.
■ Product features
1. Multiple Power Input Adapter
The accessory supports two power input options: an external AC 220V power source and a built-in rechargeable lithium battery. When connected to an external power source, the power management board automatically switches the power supply to the mains and intelligently manages the charging of the internal battery. Conversely, when the external power source is disconnected, it automatically switches to the internal battery, ensuring continuous operation and data monitoring.
2. Precise Voltage Conversion
The power management board features voltage conversion circuitry that converts AC 220V mains power into different DC voltage levels to meet the power requirements of different modules in the device.
3. Power Distribution and Load Balancing
Power is rationally distributed to each functional module of the ECG machine, dynamically adjusting the power supply based on each module's real-time power requirements.
4. Circuit Protection
Multiple built-in protection circuits monitor power input and output in real time.
■ Products Parameters
Product Name | power management board |
PN | CM1200B_POWER_B |
Applicable machine | Comen CM1200B |
Power Input | AC 220V (±10%), 50/60Hz; Built-in lithium battery |
Output voltage | +5V (±0.1%), +12V (±0.1%), -12V (±0.1%), and other DC voltages |
Power conversion efficiency | ≥95%
|
Standby power consumption | ≤5W |
Protection function | Overvoltage protection, undervoltage protection, overcurrent protection, short circuit protection |
Fault Diagnosis | Supports intelligent fault diagnosis, generating detailed fault codes to provide feedback on fault type and location. |
■ FAQ
Q1: If the ECG machine suddenly fails to power on, is it related to the power management board?
A1: First, check whether the external power connection is normal. If everything is normal, the device's inability to power on may be due to a problem with the power management board. Contact a professional repair technician for repair.
Q2: During use, the ECG machine experiences abnormal electromagnetic interference. Is this related to the power management board?
A2: There is a certain correlation. A fault in the power management board, such as a failure in the filter circuit, may prevent the effective removal of clutter interference from the mains, thereby affecting ECG signal acquisition and generating abnormal electromagnetic interference.
Q3: How do I determine if the power management board needs to be replaced?
A3: If the device frequently shuts down automatically, fails to power on despite normal external power, detects abnormal power output voltage (deviations exceeding ±0.5% from the standard value), or experiences severe electromagnetic interference that is determined to be caused by the power supply, the power management board is likely faulty. Replacing the power management board is recommended.
■ Product Picture
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller
Year Established:
2015
Employee Number:
20~50
Ecer Certification:
Verified Supplier
China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te... China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te...
Get in touch with us
Leave a Message, we will call you back quickly!