Payment Terms | In full before the shipment |
Delivery Time | 2-3 working days |
Packaging Details | Carton |
Product Name | Mindray Anesthetic Gas (AG) Module P/N 115-043908-00 |
Brand | Mindray |
Part No . | 115-043908-00 |
MOQ | One piece |
Condition | New and original |
Warranty | 90 days |
Payment Method | T/T ,western union ,Paypal |
Delivery Method | DHL ,UPS ,Fedex etc |
Brand Name | Mindray |
Model Number | P/N 115-043908-00 |
Certification | CE |
View Detail Information
Explore similar products
Patient Monitor Mainboard Module Maintenance PHiliph G60 G50 Monitor Mainboard
Patient Monitor Module Mindray BIS 6800-30-50486 Module Complete Set in Good
Patient Monitor Module Goldway G50 G60 Monitor Blood Pressure Module Parameter
NIBP SPO2 Hospital Vital Signs Monitor , White M3001a Module
Product Specification
Payment Terms | In full before the shipment | Delivery Time | 2-3 working days |
Packaging Details | Carton | Product Name | Mindray Anesthetic Gas (AG) Module P/N 115-043908-00 |
Brand | Mindray | Part No . | 115-043908-00 |
MOQ | One piece | Condition | New and original |
Warranty | 90 days | Payment Method | T/T ,western union ,Paypal |
Delivery Method | DHL ,UPS ,Fedex etc | Brand Name | Mindray |
Model Number | P/N 115-043908-00 | Certification | CE |
High Light | Mindray Anesthetic Gas AG Module ,115-043908-00 AG Module ,Hospital AG Module |
Mindray Anesthetic Gas (AG) Module P/N 115-043908-00 For Hospital
The AG module analyzes gas samples from the patient and calculates CO2, O2, N2O, and AA waveforms and related numerics that include airway respiratory rate and MAC (minimum alveolar concentration).
Measurement range:
HAL, ENF, ISO, SEV, DES: 0~30 %,
N2O: 0~100 %;
awRR: 2~100 rpm
Accuracy:
Full accuracy mode: N2O: 0~20%REL: ±2% ABS, 20~100%REL: ±3%
ABS; HAL,ENF,ISO: 0~1%REL: ±0.15% ABS, 1~5%REL: ±0.2% ABS, >5%REL, not specified; SEV: 0~1%REL: ±0.15% ABS, 1~5%REL: ±0.2% ABS, 5~8%REL: ±0.4% ABS, >8%REL, not specified;
DES:0~1%REL: ±0.15% ABS, 1~5%REL: ±0.2% ABS, 5~10%REL: ±0.4% ABS, 10~15%REL: ±0.6% ABS ,15~18%REL: ±1% ABS ,>18%REL, not specified; awRR:2~60rpm, ±1rpm, >60rpm, not specified
This measurement can be used for adults, pediatrics and neonates.
MESSAGE | CAUSE |
ALARM PRIORITY
|
MACHINE MODE WHEN CHECKED
|
DISABLE WHEN EXTERNAL AG IS IN STANDBY MODE
|
AG Hardware Error |
AG module Hardware Error.
|
Medium | Runtime | Yes |
O2 Sensor Error | Paramagnetic O2 sensor error | Medium | Runtime | Yes |
External AG Self Test Error
|
Module fault or communication failure between the module and anesthesia system
|
Low | Runtime | Yes |
AG Hardware Malfunction
|
AG module hardware malfunction. The AG module enters Standby and measurement stops
|
High | Runtime | Yes |
AG Init Error |
The AG module was installed improperly or malfunctioned.
|
High | Runtime | Yes |
AG No Watertrap |
The AG module watertrap was installed improperly or not installed.
|
Low | Runtime | Yes |
AG Watertrap Type Wrong
|
When the patient type is infant, but the watertrap type is adult/pediatric, this alarm will be triggered
|
Low | Runtime | Yes |
AG Change Watertrap
|
When the actual flow is less than 75 % of the set flow, the alarm indicates that the watertrap is gradually occluded and it is necessary to replace the water trap
|
Medium | Runtime | Yes |
AG Comm Stop |
AG module malfunction or communication failure.
|
High | Runtime | No |
AG Airway Occluded
|
Pump rate is lower than 20 ml/min for 1 second.
|
High | Runtime | Yes |
AG Zero Failed |
Gas measurements may have bad accuracy during zeroing
|
Low | Runtime | Yes |
Mixed Agent and MAC < 3
|
MAC < 3 | Low | Runtime | Yes |
Mixed Agent and MAC ≥ 3 | MAC ≥ 3 | Medium | Runtime | Yes |
Mixed Agent |
Two anesthetic agents are detected but MAC is an invalid value.
|
Medium | Runtime | Yes |
External AG Module Disconnected
|
The external AG module has been disconnected and no O2 sensor is connected
|
High | Runtime | Yes |
Incompatible AG Software Version
|
The AG Version Limit is On, and the AG module is loaded while the AG software version is lower than 1.7.3.0
|
High | Runtime | No |
CO2Over Range N 2 over Range Hal Over Range Enf Over Range Iso Over Range Sev Over Range Des Over Range O2 Over Range Rate Over Range
|
The monitoring value exceeds the measurable range |
Low | Runtime | Yes |
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller
Year Established:
2015
Employee Number:
20~50
Ecer Certification:
Verified Supplier
China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te... China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te...
Get in touch with us
Leave a Message, we will call you back quickly!