Product Name | PHiliph VS2+ Patient Monitor Parameter NBP Spo2 Panel Board Connector 453564200151 |
Brand | PHiliph |
Use for | PHiliph VS2+ Patient Monitor |
MOQ | One piece |
Warranty | 90 days |
Condition | Used |
Part No | 453564200151 |
Material | Plastic |
Brand Name | PHiliph |
Model Number | 453564200151 |
View Detail Information
Explore similar products
Patient Monitor Accessories Goldway UT4000 Monitor Blood Pressure Plate Great
Mindray PM7000 Patient Monitor Accessories Keyboard Silicone 7000-20-24395
Well-chosen Patient Monitor Mainboard Goldway G30 40 60 70 80 UT4000B UT6000
Patient Monitor Repair Parts GE Dash4000 Patient Monitor Flat Cable in ready
Product Specification
Product Name | PHiliph VS2+ Patient Monitor Parameter NBP Spo2 Panel Board Connector 453564200151 | Brand | PHiliph |
Use for | PHiliph VS2+ Patient Monitor | MOQ | One piece |
Warranty | 90 days | Condition | Used |
Part No | 453564200151 | Material | Plastic |
Brand Name | PHiliph | Model Number | 453564200151 |
High Light | 453564200151 Patient Monitor Parts ,NBP Spo2 Panel Patient Monitor Parts ,NBP Spo2 Panel Board Connector |
PHiliphh VS2+ Patient Monitor Parameter NBP Spo2 Panel Board Connector 453564200151
Parameter Panel Board 453564200151 of PHiliphh VS2+ Patient Monitor is made of plastic ,which includes NBP and Spo2 connector .The panel connector is to connect NBP and Spo2 accessories to make NBP and Spo2 function
NBP Test
The NBP test examines the performance of noninvasive blood pressure measurements. When checking the NBP module, perform the following steps:
To perform this test, you need the following tests:
NBP problem
Symptoms | Possible cause | Action |
The NBP cuff will not inflate. | The tube or cuff is bent or twisted. | Straighten the tube or cuff. |
Air leaks from tube or cuff. | Replace the cuff and make sure there are no air leaks in the tube. | |
The NBP module is malfunctioning. | Replace the NBP module. replace the motherboard | |
NBP measurements are not displayed. | Wrong size cuff or improper cuff placement. | Use the correct cuff size and ensure correct cuff placement. |
There is a problem external to the monitor. | Make sure the tubing is straight and free of kinks. Replace the cuff and make sure there are no air leaks in the tube. | |
Incorrect initial inflation pressure setting. | Ensure all external blood pressure reading requirements are met and the patient is not excessively mobile | |
An NBP module error has occurred. | Replace the NBP module. replace the motherboard | |
NBP measurements are not reliable | The cuff is the wrong size, or the cuff is placed incorrectly. | Use the correct cuff size and ensure correct cuff placement. |
There is an external problem. | Ensure that all external blood pressure reading requirements are met and that the patient is not excessively mobile. | |
Incorrect initial inflation pressure setting. | Specify the correct initial inflation pressure. | |
Calibration is not reliable. | Recalibrate the NBP module | |
NBP initial pressure is too high. | The cuffs are too tight. | Make sure the cuff is properly fastened properly. |
Incorrect initial inflation pressure setting. | Specify the correct initial inflation pressure. |
Removing the NBP module
Caution
After replacing the NBP module, the NBP cycle count must be reset and the NBP test run.
1.Separate the front panel from the rear case assembly.
2. Disconnect the NBP cable from the motherboard.
3.Disconnect the NBP tubing from the motherboard.
4.Remove the three Torx T10 screws from the metal bracket that attaches the NBP module assembly to the motherboard
5.Remove the assembly from the front housing.
Thank you for your attention .If you're interested in PHiliphh VS2+ Patient Monitor Parameter NBP Spo2 Panel Board Connector 453564200151 ,feel free to contact us .Thank you .
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller
Year Established:
2015
Employee Number:
20~50
Ecer Certification:
Verified Supplier
China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te... China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te...
Get in touch with us
Leave a Message, we will call you back quickly!