Payment Terms | Full before shipment |
Delivery Time | 3-5 working days |
Packaging Details | Carton |
Product Name | TR60-F Mindray IMEC7 IMEC8 IMEC10 IMEC12 IPM8 IPM9 IPM10 IPM12 MEC T5 T6 T8 Series Patient Monitor Printer Recorder |
Brand | Mindray |
Model No . | TR60-F |
Applicated Model | IMEC7 IMEC8 IMEC10 IMEC12 IPM8 IPM9 IPM10 IPM12 MEC T5 T6 T8 |
MOQ | One piece |
Type | Thermal array |
Speed | 25 mm/s, 50 mm/s |
Trace | 3 |
Warranty | 90 days |
Delivery Method | DHL,UPS ,Fedex ,etc |
Brand Name | Mindray |
Model Number | TR60-F |
View Detail Information
Explore similar products
Patient Monitor Accessories Goldway UT4000 Monitor Blood Pressure Plate Great
Mindray PM7000 Patient Monitor Accessories Keyboard Silicone 7000-20-24395
Well-chosen Patient Monitor Mainboard Goldway G30 40 60 70 80 UT4000B UT6000
Patient Monitor Repair Parts GE Dash4000 Patient Monitor Flat Cable in ready
Product Specification
Payment Terms | Full before shipment | Delivery Time | 3-5 working days |
Packaging Details | Carton | Product Name | TR60-F Mindray IMEC7 IMEC8 IMEC10 IMEC12 IPM8 IPM9 IPM10 IPM12 MEC T5 T6 T8 Series Patient Monitor Printer Recorder |
Brand | Mindray | Model No . | TR60-F |
Applicated Model | IMEC7 IMEC8 IMEC10 IMEC12 IPM8 IPM9 IPM10 IPM12 MEC T5 T6 T8 | MOQ | One piece |
Type | Thermal array | Speed | 25 mm/s, 50 mm/s |
Trace | 3 | Warranty | 90 days |
Delivery Method | DHL,UPS ,Fedex ,etc | Brand Name | Mindray |
Model Number | TR60-F | ||
High Light | Patient Monitor Printer Recorder ,Mindray IMEC7 Patient Monitor Printer Recorder ,IPM9 Patient Monitor Printer Recorder |
TR60-F Mindray IMEC7 IMEC8 IMEC10 IMEC12 IPM8 IPM9 IPM10 IPM12 MEC T5 T6 T8 Series Patient Monitor Printer Recorder
About Recorder
The recorder receives data from the motherboard and sends it to the thermal print head for printing. There is a hard button (start/stop recording) and a green LED on the front of the recorder. It is connected to the motherboard.
The following diagram shows its operating principle:
Module | Description |
Power interface | Introduces a DC from the main board. |
Power module | The input power is converted to a voltage suitable for each module and then forwarded to each module. |
CPU | Communication between control modules. |
Signal interface | Controls the communication between the main board and the recorder CPU. |
Motor drive circuit | Receives control signals from the CPU and forwards them to the stepper engine. |
Key&LED interface | Includes a button and an LED which are directly controlled by the CPU. |
Recorder
Type | Thermal array |
Speed | 25 mm/s, 50 mm/s |
Trace | 3 |
Recorder Check
1. Print an ECG trace. The recorder should print correctly and the printout should be clean.
2. If the configuration recorder runs out of paper and other problems occur, the display should provide the required information. When the problem is resolved, the recorder should work normally.
3. Enable automatic alarm logging for all parameters and set a limit outside the alarm limit set for each parameter. In the event of a parameter alarm, the corresponding alarm recording must be activated.
Recorder Failures
Possible Cause | Corrective Action |
Recorder module disabled | 1. Check if the recorder status indicator is turned on 2. If yes, enable the module in the [Factory Maintenance] menu. If not, look at other possible reasons. |
Paper reversed | Re-install the paper roll. |
Cable defective or poorly connected | 1. Check that the cable between the recorder and the motherboard is properly connected. 2. Check the connecting cables and connectors for damage. |
Recorder power supply failure | Check if the power module outputs 5 V DC and 12V DC correctly. |
Recorder failure | Replace the recorder |
Possible Cause | Corrective Action |
The paper roll is not installed correctly | Stop the recorder and reinstall the paper roll. |
Print head dirty | 1. Check the thermal print head and paper roller for foreign objects. 2. Clean the thermal printhead with a suitable cleaning solution. |
Print head failure | Replace the print head. |
Recorder failure | Replace recorder. |
Removing the Recorder (Optional)
1.Push the two clips aside and take out the recorder driver board, as shown below:
2.Unscrew the two PT2X6 screws and disconnect the cable and flexible cable between the recorder driver board and the recorder keyboard, as shown below. Then remove the thermal print head and recorder driver board.
3.Remove the keyboard by removing the two PT2X6 screws shown below.
If you're interested in TR60-F Mindray IMEC7 IMEC8 IMEC10 IMEC12 IPM8 IPM9 IPM10 IPM12 MEC T5 T6 T8 Series Patient Monitor Printer Recorder ,feel free to contact us .Thank you .
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller
Year Established:
2015
Employee Number:
20~50
Ecer Certification:
Verified Supplier
China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te... China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te...
Get in touch with us
Leave a Message, we will call you back quickly!