China factories

China factory - China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

  • China,Guangzhou ,Guangdong
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China GE Solar 8000 8000i 8000m Marquette TRAM 451M GE TRAM 451N Module
China GE Solar 8000 8000i 8000m Marquette TRAM 451M GE TRAM 451N Module

  1. China GE Solar 8000 8000i 8000m Marquette TRAM 451M GE TRAM 451N Module
  2. China GE Solar 8000 8000i 8000m Marquette TRAM 451M GE TRAM 451N Module
  3. China GE Solar 8000 8000i 8000m Marquette TRAM 451M GE TRAM 451N Module
  4. China GE Solar 8000 8000i 8000m Marquette TRAM 451M GE TRAM 451N Module

GE Solar 8000 8000i 8000m Marquette TRAM 451M GE TRAM 451N Module

  1. MOQ: 1pcs
  2. Price:
  3. Get Latest Price
Payment Terms T/T(wire transfer), Western Union, Paypal
Delivery Time 3-5 working days
Packaging Details Carton
Product Name GE Solar 8000 8000i 8000m Marquette TRAM 451M GE TRAM 451N Module
Brand GE
Part No. 451N
Processing main processo Motorola 68000, 16/32 bit, 14.75MHz
Input/Output Processor Intel 80C152, 8-bit, 14.75MHz
Data Acquisition Processor Intel 80C152, 8-bit, 14.75MHz
Sp02 processor Intel 80C196, 8-bit, 7.3MHz
MOQ one piece
Warranty 90 days
Delivery Method DHL,UPS ,Fedex ,etc
Packaging Carton
Condition Used
Brand Name GE
Model Number 451N

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T(wire transfer), Western Union, Paypal Delivery Time 3-5 working days
Packaging Details Carton Product Name GE Solar 8000 8000i 8000m Marquette TRAM 451M GE TRAM 451N Module
Brand GE Part No. 451N
Processing main processo Motorola 68000, 16/32 bit, 14.75MHz Input/Output Processor Intel 80C152, 8-bit, 14.75MHz
Data Acquisition Processor Intel 80C152, 8-bit, 14.75MHz Sp02 processor Intel 80C196, 8-bit, 7.3MHz
MOQ one piece Warranty 90 days
Delivery Method DHL,UPS ,Fedex ,etc Packaging Carton
Condition Used Brand Name GE
Model Number 451N
High Light 8000m Marquette TRAM451N Module Marquette TRAM

GE Solar 8000 8000i 8000m Marquette TRAM 451M GE TRAM 451N Module

 

 

Tram module

 

Processing main processor: Motorola 68000, 16/32 bit, 14.75MHz

 

Input/Output Processor: Intel 80C152, 8-bit, 14.75MHz

 

Data Acquisition Processor: Intel 80C152, 8-bit, 14.75MHz

Sp02 processor: Intel 80C196, 8-bit, 7.3MHz

 

 

Tram module problems

data not showing

 

1. Verify that the patient or simulator leads are properly connected to the tram module in the tram housing.

2. Verify that the tram module is fully inserted and turned on.

3. Verify that the tram cover is open.

4. Select the Software revision menu and verify that the software file number for the RACCOMM, RACDAS or TRAM module exists. „

  • If an incompatible software REV message is displayed, refer to "Changing the software level".
  • Check for loose or faulty cables from the patient monitor to the tram housing. „
  • Circulates power to the outer shell of the tram. „
  • View the error log for the TRAM module and patient monitor.
  • Replace the tram module with a known good module. „
  • The streetcar-style housing was replaced with a known good housing.

 

Item name

GE solar 8000 8000i 8000m Marquette TRAM 451M GE TRAM 451N module

 

Brand GE
Model 451N
Use place Hospital Devices; Medical Care; ICU;
Deliver time 3-5 days
Warranty 90 days

 

 

 

Tram housing

 

Tram housing (remote acquisition case) to acquire patient data for patient monitor. There are two Tram 2 enclosures available for the display: „

--Tram 2 housing - accommodates one Tram module. „

--Tram - rac4A housing - contains one tram module and two additional single-height modules. Shown below is a tram-rac4a enclosure with a tram module and two single-parameter modules plugged into it.

 

 

 

TRAM-NET provides a network to communicate with bedside periPHiliphhiliperals and acquisition modules.

NOTE: If any configuration has two tram connected, there must be power. The following devices can be connected to one of the two TRAM-NET ports on the Solar8000M/i monitor. The connector is 9-pin, D-type.

  • Tram-rac4a housing with or without power
  • Tram-rac2 housing
  • Tram-rac4 housing with or without power supply
  • Patient Data Module (PDM) connected to TRAM-NET2/ePort connector

 

 

 

Tram-rac4 housing

 

Tram-rac2 housing

 

Tram rac 4a housing with and without power

 

 

Cautions

Beware of equipment damage. Before plugging the power cord into an AC outlet, connect the trolley case to the solar powered 8000M/i patient monitor. Connecting these devices to a powered solar powered 8000M/i patient monitor may damage the connectors.

 

 

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller

  • Year Established:

    2015

  • Employee Number:

    20~50

  • Ecer Certification:

    Verified Supplier

China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te... China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te...

+ Read More

Get in touch with us

  • Reach Us
  • China World Technology Medical Equipment Service Group
  • TianHe District,GuangZhou,GuangDong
  • https://www.patients-monitor.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement