Payment Terms | T/T, Western Union, PayPal |
Supply Ability | 1-20 Pieces |
Delivery Time | 1-3 Working Days |
Packaging Details | Carton Packing |
Shipping Methods | DHL, EMS, UPS or ACS |
Lead Time | 2–7 days |
Contition | Excellent |
Shipping Time | Within 1-3 work days after payment |
Payment | Western Union, Paypal, T/T |
Material | Plastic, Metal |
Model | TEC-5521C |
Use | Defibrillator |
Brand Name | NIHON KOHDEN |
Model Number | TEC-5521C |
View Detail Information
Explore similar products
Patient Monitor Motherboard pm7000 CS9K-30 1653 Mindray PM-7000 Monitor
Medical Equipment Fetal Monitor Medical Equipment Accessories FM20 Fetal Monitor
CERMA Xenon Lamp 175w PE175BFA Medical Accessories Consumables Equipment
P/N 2003768-001 Whole Flax Cable For GE DASH4000 Monitor
Product Specification
Payment Terms | T/T, Western Union, PayPal | Supply Ability | 1-20 Pieces |
Delivery Time | 1-3 Working Days | Packaging Details | Carton Packing |
Shipping Methods | DHL, EMS, UPS or ACS | Lead Time | 2–7 days |
Contition | Excellent | Shipping Time | Within 1-3 work days after payment |
Payment | Western Union, Paypal, T/T | Material | Plastic, Metal |
Model | TEC-5521C | Use | Defibrillator |
Brand Name | NIHON KOHDEN | Model Number | TEC-5521C |
Here are the precautions for using the NIHON KOHDEN Cardiolife TEC-5521C defibrillator power supply, described in English bullet points:
Lethal Voltage Hazard: The power supply unit (PSU) contains extremely high voltages, both from the AC input and most critically from its internal high-voltage capacitor bank. This charge can remain lethal even after the unit is disconnected from power. Only qualified biomedical technicians trained in high-voltage safety may handle it.
Complete Power Disconnection: Before any inspection or service, you MUST:
Disconnect the defibrillator from the AC wall outlet.
Remove the main internal battery pack.
Follow the manufacturer's specific procedure to safely discharge all high-voltage capacitors completely. Never assume they are discharged.
Electrostatic Discharge (ESD) Protection: Handle the PSU as a static-sensitive device. Use an anti-static wrist strap and a grounded work surface to prevent ESD damage to its internal electronics.
Prevent Liquid Ingress: Never expose the power supply or the defibrillator to liquids or high humidity. This can cause catastrophic failure, short circuits, and pose a severe shock hazard.
Avoid Physical Damage: Do not drop or apply mechanical shock to the PSU. Internal components, particularly capacitors and transformers, can be damaged, leading to hidden failures.
Use Only Approved Replacements: Always replace with a NIHON KOHDEN-authorised power supply module. Using a non-approved or generic part can compromise the entire device's safety, performance, and regulatory compliance (e.g., FDA, CE Mark), potentially leading to inaccurate energy delivery or patient/operator harm.
Secure All Connections: After installation, ensure all internal power connectors and harnesses are firmly and correctly seated. A loose connection can lead to arcing, intermittent operation, or complete failure during a critical procedure.
Verify Battery Compatibility: Only use the manufacturer-specified battery type (e.g., the correct chemistry and model of sealed lead-acid or lithium-ion battery). An incorrect battery can damage the charging circuitry, cause overheating, or fail to provide adequate backup power.
Perform Full Functional Testing: After any service involving the PSU, a complete performance verification with a defibrillator analyzer is mandatory. This must include:
Testing AC operation and automatic switchover to battery power.
Verifying the battery charging function.
Calibrating and measuring the actual energy output (in joules) at multiple settings to ensure accuracy.
Observe Thermal Precautions: Ensure the defibrillator's ventilation ports are unobstructed. The PSU generates heat during operation and charging; proper airflow is essential to prevent overheating and premature failure.
Routine Performance Checks: Incorporate the PSU's critical functions (battery runtime, automatic switching, etc.) into the device's scheduled preventive maintenance and performance verification routines.
Documentation: Meticulously document all service actions, including the date, reason for replacement, part number of the new PSU, and results of all post-repair safety and performance tests. This is a vital part of the device's medical history.
No User Servicing: This is not a user-serviceable component. Clinical operators must never open the defibrillator casing. Any power-related issues (failure to charge, power faults, error messages) must be reported immediately to the biomedical engineering department or authorised service provider.
Proper Disposal: Follow local regulations for the disposal of electronic waste (e-waste). Defibrillator power supplies contain components that require specific recycling or disposal procedures.
Company Details
Year Established:
2011
Total Annual:
1000000-3000000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
Guangzhou YIGU Medical Equipment Service Company is the medical maintenance third-party service that devote to develop the most professional, most well-equipped service.We provide service for various hospitals, clinics, original agents, schools, the third-party companies and oversea clients in medic... Guangzhou YIGU Medical Equipment Service Company is the medical maintenance third-party service that devote to develop the most professional, most well-equipped service.We provide service for various hospitals, clinics, original agents, schools, the third-party companies and oversea clients in medic...
Get in touch with us
Leave a Message, we will call you back quickly!