Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"DS4-SO2-100 Solid-state Polymer Electrochemical Sulfur Dioxide Sensor For","imgUrl":"https:\/\/img.ismap.com\/nimg\/10\/17\/8cf1a8b7153ff68139af54c902ca-200x200-1\/ds4_so2_100_solid_state_polymer_electrochemical_sulfur_dioxide_sensor_for.jpg","attrs":{"Brand Name":"EC","Model Number":"DS4-SO2-100","Place of Origin":"Germany","Minimum Order Quantity":"1pcs"}}
{"title":"H2S-AH High Current Hydrogen Sulfide Sensor for Portable Devices 0.03 PPM","imgUrl":"https:\/\/img.ismap.com\/nimg\/e9\/de\/2c3edff3ffc6e6ffe104cf9106a5-200x200-1\/h2s_ah_high_current_hydrogen_sulfide_sensor_for_portable_devices_0_03_ppm_resolution_2_year_service_life.jpg","attrs":{"Brand Name":"alphasense","Model Number":"H2S-AH","Place of Origin":"Britain","Minimum Order Quantity":"1"}}
{"title":"NH3-B1 Four Electrode Electrochemical Ammonia Sensor (NH3 sensor) Is Used In","imgUrl":"https:\/\/img.ismap.com\/nimg\/3b\/76\/709cbd27e1256f889d1932c83ee4-200x200-1\/nh3_b1_four_electrode_electrochemical_ammonia_sensor_28nh3_sensor_29_is_used_in_ammonia_gas_transmitter.jpg","attrs":{"Brand Name":"alphasense","Model Number":"NH3-B1","Place of Origin":"Britain","Minimum Order Quantity":"1"}}
{"title":"H2S-B4 High Resolution Hydrogen Sulfide Sensor (H2S sensor) Is Used To Monitor","imgUrl":"https:\/\/img.ismap.com\/nimg\/93\/a5\/26fe289e29911b4d52b464ddf558-200x200-1\/h2s_b4_high_resolution_hydrogen_sulfide_sensor_28h2s_sensor_29_is_used_to_monitor_trace_hydrogen_sulfide_in_air_quality.jpg","attrs":{"Brand Name":"alphasense","Model Number":"H2S-B4","Place of Origin":"Britain","Minimum Order Quantity":"1"}}
{"title":"NO2-A1 Nitrogen Dioxide Sensor (Portable NO2 Sensor) For Nitrogen Dioxide","imgUrl":"https:\/\/img.ismap.com\/nimg\/8e\/e9\/481f097eb9ce0c098d1848168c96-200x200-1\/no2_a1_nitrogen_dioxide_sensor_28portable_no2_sensor_29_for_nitrogen_dioxide_portable_monitor.jpg","attrs":{"Brand Name":"alphasense","Model Number":"NO2-A1","Place of Origin":"Britain","Minimum Order Quantity":"1"}}
{"title":"NO-A1 Nitric Oxide Gas Sensor NO sensor Used For Automobile Exhaust Detection","imgUrl":"https:\/\/img.ismap.com\/nimg\/ad\/40\/82c7966c902dc6957c764eec744c-200x200-1\/no_a1_nitric_oxide_gas_sensor_no_sensor_used_for_automobile_exhaust_detection.jpg","attrs":{"Brand Name":"Alphasense","Model Number":"NO-A1","Place of Origin":"UK","Minimum Order Quantity":"1"}}
Adopting a three-electrode design, it utilizes solid-state polymer electrochemical technology. The sensor mainly consists of a working electrode, counter electrode, reference electrode, and solid-state electrolyte. SO₂ gas reaches the working electrode of the sensor through diffusion holes, where an electrochemical oxidation or reduction reaction occurs on the porous micro-surface of the electrode. Protons generated by the reaction migrate to the counter electrode through the polymer electrolyte, producing a current signal proportional to the concentration of the measured gas.
Performance Characteristics:
Wide Voltage Range: Operates at 3.3V to 12V DC, with 5V DC recommended.
Wide Temperature Range: Works at -40°C to +55°C without the need for temperature compensation.
Rapid Response: Quickly detects changes in gas concentration and achieves stable measurement results in a short time for real-time monitoring.
High Precision and Linearity: Features excellent linearity and high measurement accuracy, enabling accurate measurement of SO₂ gas at different concentrations.
Long-term Stability: Exhibits minimal zero-point drift and stable signals during long-term use. The anti-poisoning design ensures reliable performance in complex environments.
Low Power Consumption: Supports a low-power sleep mode, with customizable sleep/wake functions, suitable for IoT and battery-powered applications.
Compact and Lightweight: Adopts the standard 4-series industrial size, a cylindrical design of 20x16.6mm, facilitating integration into various new or existing products.
Simple Output: Supports simple UART digital output (3.3V half-duplex single-wire mode), making data collection convenient and easy to integrate with microcontrollers or IoT systems.
Safe and Reliable: Has intrinsic safety certifications (Ex ia IIC T6 Ga), complies with RoHS standards, and is safe and environmentally friendly.
Technical Parameters:
Range: Commonly 0-100ppm, with other ranges available.
Resolution: Up to 0.5ppm or higher; in the 0-5ppm range, the resolution can reach 0.001ppm.
Sensitivity: At 20°C, the sensitivity is 0.37±0.07μA/ppm.
Baseline Drift: Within -20°C to 50°C, the baseline drift is less than 0.5ppm.
Cross-sensitivity: Has certain cross-sensitivities to gases such as hydrogen sulfide, carbon monoxide, nitric oxide, nitrogen dioxide, hydrogen, and ammonia, but the values are small.
Application Fields:
Environmental Protection: Used for monitoring ambient air quality, detecting the concentration of SO₂ in the atmosphere, providing data support for environmental protection departments, and assisting in evaluating environmental pollution status and formulating environmental protection policies.
Industrial Fields: In industries such as metallurgy, power, petrochemicals, and mining, it is used to monitor waste gas emissions during industrial production and the concentration of SO₂ in the production environment to ensure production safety and environmental compliance.
Flue Gas Desulfurization Systems: Used for the automatic control of flue gas desulfurization processes. By real-time monitoring of SO₂ concentration, it optimizes reaction conditions, improves desulfurization efficiency, and reduces sulfur dioxide emissions.
Fire Rescue and Emergency Detection: Detects the concentration of SO₂ in the air at fire scenes or other emergency scenarios, providing safety guidance for rescue personnel and ensuring the smooth progress of rescue work.
Detectable Gas
Sulfur dioxide (SO₂)
Sensor Type
Solid-state polymer electrochemical sensor
Range
Standard range: 0-100ppm (other ranges are optional, such as 0-5ppm, etc.)
Resolution
- Standard range: 0.5ppm - 0-5ppm range: 0.001ppm
Sensitivity
At 20℃: 0.37±0.07μA/ppm
Baseline Drift
Within -20℃ to 50℃: <0.5ppm
Operating Voltage
3.3V-12V DC (5V DC recommended)
Operating Temperature
-40℃ to +55℃ (no temperature compensation required)
Response Time
Fast response, capable of real-time monitoring of gas concentration changes
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer,Trading Company
Year Established:
2006
Total Annual:
900000-1000000
Employee Number:
50~80
Ecer Certification:
Verified Supplier
Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph... Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph...