Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"0393.0000 Gas Oxygen Sensor Easy To Replace Pre-Calibrated with Plastic Housing","imgUrl":"https:\/\/img.ismap.com\/nimg\/ba\/b4\/42b5ede1f34c213f05b3b28d7d6b-200x200-1\/0393_0000_gas_oxygen_sensor_easy_to_replace_pre_calibrated_with_plastic_housing.jpg","attrs":{"Model Number":"0393.0000","Place of Origin":"UK","Minimum Order Quantity":"1","Payment Terms":"L\/C,D\/A,D\/P,T\/T,Western Union,MoneyGram"}}
{"title":"2FO AA625-180 Air Oxygen Sensor Combustion Efficiency For Fixed Gas Detector","imgUrl":"https:\/\/img.ismap.com\/nimg\/87\/ec\/1d93bb7c9bc17074c851a4ac56e0-200x200-1\/2fo_aa625_180_air_oxygen_sensor_combustion_efficiency_for_fixed_gas_detector.jpg","attrs":{"Brand Name":"CITY","Model Number":"2FO AA625-180","Place of Origin":"UK","Minimum Order Quantity":"1"}}
{"title":"AO2 PTB-18.10 AA428-210 Gas Oxygen Sensor Electrochemical Partial Pressure O2","imgUrl":"https:\/\/img.ismap.com\/nimg\/91\/fe\/f4d1d5e567cd56f1dfc1d29b714f-200x200-1\/ao2_ptb_18_10_aa428_210_gas_oxygen_sensor_electrochemical_partial_pressure_o2_molex_connector.jpg","attrs":{"Brand Name":"CITY","Model Number":"AO2 PTB-18.10","Place of Origin":"UK","Minimum Order Quantity":"1"}}
{"title":"MOX4 MOX-4 AA829-M20 Oxygen Gas Sensor Medical Equipment White ABS Battery","imgUrl":"https:\/\/img.ismap.com\/nimg\/09\/23\/bf7b7dc0c3d60c54861cd1c613b1-200x200-1\/mox4_mox_4_aa829_m20_oxygen_gas_sensor_medical_equipment_white_abs_battery.jpg","attrs":{"Brand Name":"CITY","Model Number":"MOX-4 MOX4 AA829-M20","Place of Origin":"UK","Minimum Order Quantity":"1"}}
{"title":"MAX250E R125P03-002 Oxygen Gas Sensor Electrochemical Dissolved For Breathing","imgUrl":"https:\/\/img.ismap.com\/nimg\/a0\/18\/078f7d1fa2c9882654f690297f51-200x200-1\/max250e_r125p03_002_oxygen_gas_sensor_electrochemical_dissolved_for_breathing_equipment.jpg","attrs":{"Brand Name":"MAXTEC","Model Number":"MAX250E","Place of Origin":"USA","Minimum Order Quantity":"1"}}
{"title":"O2-C2 Oxygen Gas Sensor Electrochemical O2 Sensor For Oxygen Alarm Two Year Life","imgUrl":"https:\/\/img.ismap.com\/nimg\/c7\/2f\/86058eb7440e4162e8e912c0930d-200x200-1\/o2_c2_oxygen_gas_sensor_electrochemical_o2_sensor_for_oxygen_alarm_two_year_life.jpg","attrs":{"Brand Name":"Alphasense","Model Number":"O2-C2","Place of Origin":"UK","Minimum Order Quantity":"1"}}
{"title":"O2-M2 Gas Oxygen Sensor Lead Free In Coal Mine Steel And Petrochemical","imgUrl":"https:\/\/img.ismap.com\/nimg\/2a\/04\/180242471aac33ea58ed4d030eac-200x200-1\/o2_m2_gas_oxygen_sensor_lead_free_in_coal_mine_steel_and_petrochemical.jpg","attrs":{"Brand Name":"Alphasense","Model Number":"O2-M2","Place of Origin":"UK","Minimum Order Quantity":"1"}}
Product Type: Spare oxygen sensor for flue gas analyzers1.
Compatible Instruments: Testo 340, Testo 350 flue gas analyzers4.
Technical Parameters:
Measurement Range: 0 - 25 Vol.%.
Accuracy: ±0.2 Vol.%.
Resolution: 0.01 Vol.%.
Response Time: < 20 s.
Weight: 38 g.
Dimensions: 40 x 30 x 30 mm (LxWxH).
Housing Material: Plastic.
Product Colour: Grey and white.
Features:
Pre - Calibrated: The sensor is pre - calibrated, and the adjustment data is stored in it. There is no need for time - consuming calibration when replacing the sensor, which is convenient and quick.
Easy to Replace: It can be easily inserted into the corresponding flue gas analyzer, allowing users to replace the sensor on their own without the need for professional tools or assistance.
Parameter
Details
Measurement Range
0–25 Vol.%
Accuracy
±0.2 Vol.%
Resolution
0.01 Vol.%
Response Time
< 20 seconds
Dimensions (L×W×H)
40 × 30 × 30 mm
Weight
38 g
Housing Material
Plastic
Color
Grey and white
Compatibility
Testo 340, Testo 350 flue gas analyzers
Calibration
Pre-calibrated (adjustment data stored internally)
Replacement Method
Tool-free insertion (user-replaceable)
Operating Temperature
Refer to compatible analyzer specifications
Storage Temperature
-20°C to +60°C
Humidity Range
Non-condensing environment
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer,Trading Company
Year Established:
2006
Total Annual:
900000-1000000
Employee Number:
50~80
Ecer Certification:
Verified Supplier
Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph... Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph...