Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Delivery Time | 3-5work days |
Measuring Range | 0-500ppm |
Sensitivity Range | 35nA/ppm ± 15nA/ppm |
Expected Operating Life | >24 months in air* |
Zero Current at 20oC | <± 100nA, typically 40nA |
Response Time at 20oC | t50 <30s calculated from 5min. expsoure time t90 <90s calculated from 5min. expsoure time |
Temperature Range | -20°C to +40°C |
Bias Potential | 0mV |
Linearity | <10% full scale |
Model Number | NH3 3E 500 SE |
View Detail Information
Explore similar products
H2S-AH Hydrogen Sulfide Sensor (High Current H2S Sensor) Is Used In Hydrogen
NH3-B1 Four Electrode Electrochemical Ammonia Sensor (NH3 sensor) Is Used In
H2S-B4 High Resolution Hydrogen Sulfide Sensor (H2S sensor) Is Used To Monitor
NO2-A1 Nitrogen Dioxide Sensor (Portable NO2 Sensor) For Nitrogen Dioxide
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Delivery Time | 3-5work days |
Measuring Range | 0-500ppm | Sensitivity Range | 35nA/ppm ± 15nA/ppm |
Expected Operating Life | >24 months in air* | Zero Current at 20oC | <± 100nA, typically 40nA |
Response Time at 20oC | t50 <30s calculated from 5min. expsoure time t90 <90s calculated from 5min. expsoure time | Temperature Range | -20°C to +40°C |
Bias Potential | 0mV | Linearity | <10% full scale |
Model Number | NH3 3E 500 SE | ||
High Light | 500ppm Gas Sensor ,Low Susceptibility Electrochemical Gas Sensor |
NH3 3E 100 SE Electrochemical Gas Sensor Ammonia Gas Sensor 0-500ppm Low Susceptibility To Abrupt Changes Of Humidity Portable & Fixed Point Applications
Features:
Amperometric 3 electrode sensor cell
Low susceptibility to abrupt changes of humidity
No CO2 interference
High selectivity
0 voltage biased operation
Typical Applications:
Portable & fixed point applications
Monitoring of IDLH levels, General Industry,
Chemical Industry, Food & Refrigeration Industry
Part Number Information:
Mini 1850-932-30009
Sensoric Classic 1850-932-30069
CTL4 Series Adaptation 1850-932-30049
CTL 7 Series Adaptation 1850-932-30079
Long Term Sensitivity Drift | <5% per 6 months |
Pressure Coefficient | <0.03% signal/mBar |
Operating Humidity | 15-90% RH non-condensing |
Effect of Humidity | No effect on zero reading during abrupt changes of RH |
Recommended Load Resistor | 100Ω |
Orientation Sensitivity | None |
Storage Life | 4 weeks in container |
Recommended Storage Temperature | 0-20°C |
Company Details
Business Type:
Manufacturer,Trading Company
Year Established:
2006
Total Annual:
900000-1000000
Employee Number:
50~80
Ecer Certification:
Verified Supplier
Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph... Yijiajie Electronics is a full range of silicon pressure sensors from the United States, FREESCALE/, GE, MEAS, SMI, and a full range of sensing and control products from the United States pressure, temperature and humidity, gas flow, current, Hall effect, etc., Japan HAMAMATSU flame, UV sensors, ph...
Get in touch with us
Leave a Message, we will call you back quickly!