Payment Terms | T/T, Western Union,Paypal |
Supply Ability | 500Pcs |
Delivery Time | 1-4working days |
Packaging Details | Standard export package |
Sensitivity: | ≥9cps/*Bq•m-3] |
Background counting rate: | ≤0.3cps |
Long-term stability (8h) error: | ≤10% |
Detector | zinc sulfide ZnS (Ag) |
Data storage: | 200,000 records can be stored |
Display: | LCD liquid crystal display |
Print data | date, time, point number and test results |
Air extraction method | active pump suction type (flow 2L/min) |
Brand Name | HUATEC |
Model Number | FJ-2500 |
Certification | ISO, CE, GOST |
Place of Origin | China |
View Detail Information
Explore similar products
NDT Non Destructive Testing Equipment , TG4500 Series Ultrasonic Thickness Gauge
Black NDT Non Destructive Testing Equipment , High Voltage Porosity Detector
SPY Holiday Detector Test / Non Destructive Testing Equipment for Pipe Corrosion
Non Destructive Testing Equipment , Wire Rope Inspection Steel Rope Flaw
Product Specification
Payment Terms | T/T, Western Union,Paypal | Supply Ability | 500Pcs |
Delivery Time | 1-4working days | Packaging Details | Standard export package |
Sensitivity: | ≥9cps/*Bq•m-3] | Background counting rate: | ≤0.3cps |
Long-term stability (8h) error: | ≤10% | Detector | zinc sulfide ZnS (Ag) |
Data storage: | 200,000 records can be stored | Display: | LCD liquid crystal display |
Print data | date, time, point number and test results | Air extraction method | active pump suction type (flow 2L/min) |
Brand Name | HUATEC | Model Number | FJ-2500 |
Certification | ISO, CE, GOST | Place of Origin | China |
High Light | radon measuring instrument ndt equipment ,usb ndt equipment ,ndt radon measuring equipment |
Radon Measuring Instrument With High Sensitivity, Easy To Use And USB Transmission Interface FJ-2500
Overview
The FJ-2500 radon meter is used in environmental monitoring, sanitation, construction engineering, home improvement, geological prospecting, seismic monitoring, scientific research and other fields. Used to detect radon in the air, radon in the soil, radon in water and radon extraction rate. The instrument complies with the measurement principles and requirements of GB50325-2001 "Code for Indoor Environmental Pollution Control of Civil Construction Engineering" and GB/T16147-1995 "Measurement Method of Scintillation Bottle for Radon Concentration in Air".
Feature
Small size, light weight, easy to carry
Human-computer interaction interface, convenient operation
High sensitivity, low power consumption,using the most classic scintillation radon method
USB data transmission interface, TCP/IP, RS485, RS232, industrial wireless communication methods are available
Main parameter index
1.Sensitivity: ≥9cps/*Bq•m-3]
2.Background counting rate: ≤0.3cps
3.Measuring range: Ambient air radon: (3~100000000) Bq/m³; soil radon: (300~400000) Bq/m3 Radon extraction rate: (0.001~10.000) Bq/*m2•s+; radon in water: (0.003~ 100) Bq/L
4.Measurement repeatability error: ≤5% (Radon room concentration 2000Bq/m3, ambient humidity 65%, temperature 25℃).
5.Long-term stability (8h) error: ≤10%
6.Power supply: Lithium-ion battery or alternating current, battery power supply can work continuously for 30h
7.Working environment: temperature: -10℃~+40℃; humidity: relative humidity ≤90% (+40℃)
8.Detector: zinc sulfide ZnS (Ag)
9.Data storage: 200,000 records can be store
10Operation mode: single point detection or continuous monitoring
11.Display: LCD liquid crystal display
12.Air extraction method: active pump suction type (flow 2L/min)
13.Measuring time: air radon: 1-30min; soil radon: 1-10min Radon extraction rate: 1-30min; radon in water: 1-30min
14.Print data: date, time, point number and test results
Sensitivity | ≥9cps/*Bq•m-3] |
Background counting rate | ≤0.3cps |
Measuring range | Ambient air radon: (3~100000000) Bq/m³; soil radon: (300~400000) Bq/m3 Radon extraction rate: (0.001~10.000) Bq/*m2•s+; radon in water: (0.003~ 100) Bq/L |
Measurement repeatability error | ≤5% (Radon room concentration 2000Bq/m3, ambient humidity 65%, temperature 25℃). |
Long-term stability (8h) error | ≤10% |
Power supply | Lithium-ion battery or alternating current, battery power supply can work continuously for 30h |
Working environment | temperature: -10℃~+40℃; humidity: relative humidity ≤90% (+40℃) |
Detector | zinc sulfide ZnS (Ag) |
Data storage | 200,000 records can be store |
Display | LCD liquid crystal display |
Air extraction method | active pump suction type (flow 2L/min) |
Measuring time | air radon: 1-30min; soil radon: 1-10min Radon extraction rate: 1-30min; radon in water: 1-30min |
Print data | date, time, point number and test results |
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Exporter,Seller
Year Established:
2007
Total Annual:
500000-1000000
Employee Number:
35~50
Ecer Certification:
Verified Supplier
HUATEC Group is a reliable manufacturer and supplier of testing instruments in Beijing China. HUATEC Group combines all the R/D and production advantage of all its own subsidiaries, takes advantage of its years marketing and sales experience in global market, contributes to offering most qualified... HUATEC Group is a reliable manufacturer and supplier of testing instruments in Beijing China. HUATEC Group combines all the R/D and production advantage of all its own subsidiaries, takes advantage of its years marketing and sales experience in global market, contributes to offering most qualified...
Get in touch with us
Leave a Message, we will call you back quickly!