Supply Ability | 1000 km/ year |
Delivery Time | 30 days |
Packaging Details | wooden drums |
Conductor | copper |
Insulation | MICA TAPE |
Voltage | Low Voltage |
Sheath | Lshf |
Armour layer | corrugated copper |
Brand Name | New Baofeng |
Model Number | YTTW |
Certification | ISO, CCC |
Place of Origin | Hebei,China |
View Detail Information
Explore similar products
Insulated Fire Proof Cable
Compound Fire Proof cable
IEC60332 Fire Proof Cable , High Temperature Rated AC 1KV - 10KV
PVC fiber & mica compound insulated fire-proof soft wire, Fire Proof Cable
Product Specification
Supply Ability | 1000 km/ year | Delivery Time | 30 days |
Packaging Details | wooden drums | Conductor | copper |
Insulation | MICA TAPE | Voltage | Low Voltage |
Sheath | Lshf | Armour layer | corrugated copper |
Brand Name | New Baofeng | Model Number | YTTW |
Certification | ISO, CCC | Place of Origin | Hebei,China |
Fire Proof Cable Super Multi Core Inorganic Mineral Insulated Corrugated Copper and Lshf Sheathed Cable
Constructions
Conductor: Stranded copper conductor
Insulation: Inorganic insulation
Operation character
Fire-resistant property
(1) According to national standards, fire-resistant wire and cable fire test method characteristic
test, according to GB12666.6
Class A, burn in fire with flame temperature 950°C, apply voltage of 750V between phase and
phase and between phase and outer sheath,it should be able to withstand for 90min without
breakdown.
Class B, bun in fire with flame temperature 750-800°C, apply voltage of 750V between phase
and phase and between phase and outer sheath,it should be able to withstand for 90min without
breakdown.
(2) According to the BS6378,flexible fireproof cable satisfies the following requirements:
Class A 650°C 3h
Class B 750°C 3h
Class C 950°C 3h
Class S 950°C 20min
Electrical characteristics
(1) Rated voltage: 0.6/1kV
(2) Rated working voltage: light load 500V, heavy load 750V;
(3) Rated current: single-core 25A-1,800A: multi-core 16A-500A;
(4) Insulation resistance: insulation resistance≥ 1000MΩkm. Cable length less than 100m,
then the insulation resistance≥ 10000MΩ;
(5) Power frequency withstand voltage: apply voltage of 2,000V and 2,500V between phase
and phase as well as phase and copper sheath of cables of 500V and 750V respectively,
they should be able to withstand for 15min without being broken down.
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
1982
Total Annual:
> 100,000,000
Employee Number:
>1000
Ecer Certification:
Active Member
Hebei New Baofeng Wire & Cable Co., Ltd. owns fixed capital of RMB 1.6 billion with 1100 staffs (among whom 86 are senior engineers and technicians, 230 are engineers and technicians). The Group Co. consists of 18 departments, 11 branches, 32 representative offices with its sales networks coveri... Hebei New Baofeng Wire & Cable Co., Ltd. owns fixed capital of RMB 1.6 billion with 1100 staffs (among whom 86 are senior engineers and technicians, 230 are engineers and technicians). The Group Co. consists of 18 departments, 11 branches, 32 representative offices with its sales networks coveri...
Get in touch with us