Packaging Details | STEEL DRUMS |
Delivery Time | 60 DAYS |
Payment Terms | L/C,T/T,OA |
Supply Ability | 100KM/YEAR |
insulation | XLPE |
specification | 1 X 2500 mm² |
voltage | 290/ 500KV |
Place of Origin | HEBEI CHINA |
Brand Name | XIN BAOFENG |
Certification | IEC STANDARD CE, ISO |
Model Number | YJLWO2,YJLWO3 |
View Detail Information
Explore similar products
110~220KV ALUMINIUM CONDUTOR XLPE Insulated High Voltage Cable
500KV COPPER XLPE INUSULATED UNDERGROUND POWER CABLE FOR HYDROPOWER STATION
High Voltage Waterproof Sheathed Power Cable 64 /110KV 123KV , High Voltage
230KV XLPE Copper Core Cable Applying to GIS Substations for thermal power
Product Specification
Packaging Details | STEEL DRUMS | Delivery Time | 60 DAYS |
Payment Terms | L/C,T/T,OA | Supply Ability | 100KM/YEAR |
insulation | XLPE | specification | 1 X 2500 mm² |
voltage | 290/ 500KV | Place of Origin | HEBEI CHINA |
Brand Name | XIN BAOFENG | Certification | IEC STANDARD CE, ISO |
Model Number | YJLWO2,YJLWO3 | ||
High Light | High Voltage Power Cable , High Voltage Wiring |
290/500KV 1X2500mm² XLPE insulated high voltage cable power cable
1,Item name : 500KV XLPE insulated electric cable
STANDARD : IEC62067 (or standard demanded by buyer )
2,Type :
YJLW02,YJLLW02 ,YJLW03,YJLLW03
3, Application :
Suitable for the places with a higher underground water level and to be used underground, in the tunnels or pipes. Such cables bear a bigger pulling force and pressure
4,Operating charactor:
1)up to 90℃, and overload when meet an emergency is 130℃ ,When short circuit (in ≤5 seconds) the highest temperature is 250℃
2)When installing or laying cable, the ambient temperature should be less than -20℃, and have to give a preheat to cable.
3)The minimum bending diameter:
Cable type Bending diameter |
Metal sheathed |
After laying | 30D0 |
During laying | 40D0 |
4)Allowed biggest axial traction force to outer diameter when laying cable (not consider the radial lateral-pressure at bent section) T=K×core NO. ×section (kg), in formula, the coefficient K value should be: the copper core get 7, the aluminum core get 4.
5)Allowed biggest lateral-press P, when cable is being bent
The single core cable is required P≤500kg/m.
P=T/R (T is indicated axial traction force; R is indicated radius of bent-wheel), Knowing from above formula, as the traction force is made up by length and weight of cable. So it lets P to applying requirement as above. Then the diameter of bent-wheel should be widened.
6)Cable laying is not being restricted by drop.
5,Certification :
6,500kv projects introduction :
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
1982
Total Annual:
> 100,000,000
Employee Number:
>1000
Ecer Certification:
Active Member
Hebei New Baofeng Wire & Cable Co., Ltd. owns fixed capital of RMB 1.6 billion with 1100 staffs (among whom 86 are senior engineers and technicians, 230 are engineers and technicians). The Group Co. consists of 18 departments, 11 branches, 32 representative offices with its sales networks coveri... Hebei New Baofeng Wire & Cable Co., Ltd. owns fixed capital of RMB 1.6 billion with 1100 staffs (among whom 86 are senior engineers and technicians, 230 are engineers and technicians). The Group Co. consists of 18 departments, 11 branches, 32 representative offices with its sales networks coveri...
Get in touch with us
Leave a Message, we will call you back quickly!