Product Specification
Packaging Details | wooden drums | Delivery Time | Negotiable |
Payment Terms | L/C,T/T,OA | Place of Origin | Hebei,China(Mainland) |
Brand Name | New Baofeng | ||
High Light | PVC sheathed power cable ,Flexible Control Cable |
Cable for Nuclear Power Station
■ Product standard
Enterprise standard (Refer to the regulated requirement specified in RCC-E nuclear island electric equipment and building rule, France)
■ Application
This product is suitable for power configuration, control, detection, communication and compensated 1E class loop of meters and instruments of nuclear island factory building of nuclear power station.
■ Product characteristics
1. Rated voltage (U0/U): 0.6/1kV;
2. Max.permissible continuous operating temperature of conductor is 90℃, for short circuit (4s) max. conductor temperature is 250℃;
3. The ambient temperature under installation -10℃~40℃;
4. The bending radius of cables are recommend as follows at installaton:
Not less than 6 times the diameter of unscreened cable;
Not less than 8 times the diameter of screened cable,
5. The lowest temperature as installationed:-40℃;
6. Used time of cable: 50 years;
7. Especial property of cable:
(1) The cable can undergo bundling combustion test specified in GB/T18380.3 (IEC332-3);
(2) The insulation wire core of cable can undergo vertical combustion test specified in GB/T18380.1 (IEC332-1)
(3) The low smoke property of cable should conforms to the regulations specified in GB/T17651 (IEC61034): light transmittance≥60;
(4) The low halogen property of cable should conform to the regulations specified in GB/T17650.2(IEC60754-2):pH≥4.3,electrical conductivity<10μs/mm;
8. Electric property of cable:
(1) Cable withstand the test of AC 3500V/5min without breakdown,
(2) Insulation resistance of cable conductor: p20 not more than 0.0172410Ω·mm2/m
(3) Constant of insulation resistance for cable: K20 not less than 367MΩ·km, K60 not less than 367MΩ·km, K90 not less than 36MΩ·km.
■ Specifications and Names
1. Power cable of 6kV used for nuclear power station
Type |
Designation |
|
Copper core |
Aluminum core |
|
WDZA—YJWJ—K3 WDZA—YJS—K3 |
WDZA—YJLWJ—K3 WDZA —YJLS— K3 |
XLPE insulated PO sheathed low fume no halogen A class flame retardant for nuclear power station of K3 kind XLPE insulated PO sheathed low fume no halogen A class flame retardant for nuclear power station of K3 kind |
Type |
Rated Voltage kV |
No. of Core |
Nom. area Cross—Section area mm2 |
WDZA—YJWJ—K3 |
6/10kV |
1 |
120~630 |
WDZA—YJLWJ—K3 |
3 |
35~95 |
|
WDZA—YJS—K3 |
|||
WDZA—YJLS—K3 |
|||
Note: The cable in above list A kind fire retardant. For B kind or C kind, use B or C to replace A only. |
2. Power cable of 1000V used for nuclear power station
Type |
Designation |
WDZA-YJWJ-K3 |
Copper conductor XLPE insulated PO sheathed low fume no halogen A class flame retardant for nuclear power station of K3 kind |
WDZA-YJLS-K3 |
Al conductor XLPE insulated PO sheathed low fume no halogen A class flame retardant for nuclear power station of K3 kind |
WDZA-WJWJ-K3 |
Copper conductor low fume no halogen flame retardant XLPE insulated PO sheathed low fume no halogen A class flame retardant for nuclear power station of K3 kind |
Type |
Rated Voltage kV |
No. of Core |
Nom. area Cross-Section area mm2 |
WDZA-YJWJ-K3,WDZA-YJLWJ-K3 WDZA-WJWJ-K3,WDZA-WJLWJ-K3 WDZA-EWJ-K3,WDZA-ELWJ-K3 WDZA-ES-K3,WDZA-ELS-K3 WDZA-WJS-K3,WDZA-WJLS-K3 WDZA-YJS-K3,WDZA-YJLS-K3 WDZA-SS-K3,WDZA-SLS-K3 |
0.6/1 |
1 |
50~400 |
2 |
2.5~70 |
||
3 |
2.5~150 |
||
4 |
2.5~150 |
||
3+1 |
3×35+1×16~3×150+1×70 |
||
6 |
2×16+4×10 2×10+4×6 |
||
Note: The cable in above list is A kind fire retardant. For B kind or C kind, use B or C to replace A only. |
3. Control cable of 1000V used for nuclear power station
Type |
Designation |
WDZA-KYJWJP-K3 |
XLPE insulated braid screened PO sheathed low fume no halogen A class flame retardant for nuclear control station of K3 kind |
WDZA-KYJSP-K3 |
XLPE insulated braid screened PO sheathed low fume no halogen A class flame retardant for nuclear control station of K3 kind |
Type |
Rated Voltage kV |
No. of Core |
Nom. area Cross-Section area mm2 |
WDZA-KYJWJ-K3,WDZA-KYJWJP-K3 WDZA-KYJWJP2-K3,WDZA-KYJWJP3-K3 WDZA-KYJS-K3,WDZA-KYJSP-K3 WDZA-KYJSP2-K3,WDZA-KYJSP3-K3 WDZA-KSS-K3,WDZA-KSSP-K3 WDZA-KSSP2-K3,WDZA-KSSP3-K3 WDZA-KES-K3,WDZA-KESP-K3 WDZA-KESP2-K3,WDZA-KESP3-K3 WDZA-KWJS-K3,WDZA-KWJSP-K3 WDZA-KWJP2-K3,WDZA-KWJSP3-K3 |
0.6/1 |
2-61 |
0.5 |
2-61 |
0.75 |
||
2-61 |
1.0 |
||
2-61 |
1.5 |
||
2-48 |
2.5 |
||
2-24 |
4 |
||
2-24 |
6 |
||
2-19 |
10 |
||
Note: The cable in above list is A kind fire retardant. For B kind or C kind, use B or C to replace A only. |
■ Main performance
No. |
Item |
Unit |
Norm |
Test mean |
1 |
DC resistance of conductor |
Accord GB3956 |
GB/T3048.4 |
|
2 |
Constant K of insulation resistance is at 120℃ at 90℃ |
MΩ/km |
3670 3.67 |
GB/T3048.5 |
3 |
Work frequency voltage test electric power cable and control cable for 5 min |
kV |
3.5 |
GB/T3048.8 |
4 |
Long time heat circulation test Test time Test voltage |
h kV |
5000 2 |
HN33-5-28 |
5 |
Fire-retardant characteristics |
|||
5.1 |
Vertical combustion test of insulation line core Time of supply fire Burn area of indication |
% |
Supply fire 15s,stop fire 15s, repeat 5 times <2.5 |
IPCEAS-19-81 |
5.2 |
Combustion test of bundled cable Kind of test Burn length of cable |
m |
B ≤2.5 |
GB/T18380.3 IEC60332-3 |
5.3 |
Test of cable smoke concentration Light transmittance |
% |
≥60 |
GB/T17651.2 IEC61034 |
5.4 |
Causticity of combustion gas of covered material PH value Electric conductibility |
μs/mm |
≥4.3 ≤10 |
IEC60754 GB/T60754 |
6 |
Nuclear environment test (for K1,K2 kind of cable only) |
|||
6.1 |
Thermal ageing test Test temperature Duration |
℃ h |
135±3 950 |
GB/T2951.1 |
6.2 |
Damp heat test Damp Temperature Duration |
% ℃ h |
95 60±2 48 |
NFC20-504 |
6.3 |
Radiation ageing time Temperature Accumulated measure Dosing rate |
℃ KGY GY/S |
70±3 250 0.28±0.14 |
IEC60544 |
6.4 |
Earthquake test Temperature D≤40mm D>40mm |
℃ |
20 8D 12D |
NFC32-021 |
6.5 |
Radiation test under LOCA accident (for K1 kind of cable only) Temperature Accumulated measure Dosing rate |
℃ KGY GY/S |
70±3 600 0.28±0.14 |
IEC60544-2 |
6.6 |
LOCA test (for K kind of cable only) |
pass |
RCC-E |
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
1982
Total Annual:
> 100,000,000
Employee Number:
>1000
Ecer Certification:
Active Member
Hebei New Baofeng Wire & Cable Co., Ltd. owns fixed capital of RMB 1.6 billion with 1100 staffs (among whom 86 are senior engineers and technicians, 230 are engineers and technicians). The Group Co. consists of 18 departments, 11 branches, 32 representative offices with its sales networks coveri... Hebei New Baofeng Wire & Cable Co., Ltd. owns fixed capital of RMB 1.6 billion with 1100 staffs (among whom 86 are senior engineers and technicians, 230 are engineers and technicians). The Group Co. consists of 18 departments, 11 branches, 32 representative offices with its sales networks coveri...
Get in touch with us
Leave a Message, we will call you back quickly!