China factories

China factory - Hebei New Baofeng Wire & Cable Co.,Ltd

Hebei New Baofeng Wire & Cable Co.,Ltd

  • China ,Hebei
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China Fire-retardant Cable For Coal Mine Special Cable
China Fire-retardant Cable For Coal Mine Special Cable

  1. China Fire-retardant Cable For Coal Mine Special Cable
  2. China Fire-retardant Cable For Coal Mine Special Cable
  3. China Fire-retardant Cable For Coal Mine Special Cable

Fire-retardant Cable For Coal Mine Special Cable

  1. MOQ: 500 Meter/MetersTrial Order
  2. Price: Negotiable
  3. Get Latest Price
Packaging Details wooden drums
Delivery Time Negotiable
Payment Terms L/C,T/T,OA
Place of Origin Hebei,China(Mainland)
Brand Name New Baofeng

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Packaging Details wooden drums Delivery Time Negotiable
Payment Terms L/C,T/T,OA Place of Origin Hebei,China(Mainland)
Brand Name New Baofeng
High Light PVC sheathed power cableInsulated power Cable

 

 

Fire-retardant Cable For Coal Mine

 

■ Product standard

MT818.2-1999,GB12972.2-91,MT386

Coal cutter flexible cables for rated voltage up to and including 1.9/3.3kV

Type

Name

Application

MC-0.38/0.66

UC-0.38/0.66

Rubber sheathed coalcutter flexible cable

For power supply of coalcutter 

or similar equipments 

of rated voltage 0.38/0.66kV

MCP-0.38/0.66

UCP-0.38/0.66

Rubber sheathed with screens 

coalcutter flexible cable

For power supply of coalcutter or similar 

equipments of rated voltage 0.38/0.66kV

MCP-0.66/1.14

UCP-0.66/1.14

Rubber sheathed with screens 

coalcutter flexible cable

For power supply of coalcutter or

 similar equipments

of rated voltage 0.66/1.14kV

MCP-1.9/3.3

Rubber sheathed with screens 

coalcutter flexible cable

For power supply of coalcutter or

 similar equipments

of rated voltage 1.9/3.3kV

■ Construction of cable

1. Power core conductor

2. Earthing core conductor

3. Control core conductor

4. Insulation

5. Insulation screens

6. Outer sheathed

7. Inner sheathed

8. Fiber woven reinforced layer

■ Structure and size of cable

No. of cod×Nominal Area

mm2

Diameter and weight of cable

MC-0.38/0.66

MCP-0.38/0.66

Power core

Earthing core

Control core

Diameter mm

Weight kg/km

Diameter mm

Weight kg/km

3×16

1×4

3×2.5

31.3~34.4

1630

33.2~36.5

1758

3×25

1×6

4×2.5

38.4~41.0

2371

40.3~44.3

2524

3×35

1×6

4×4

43.9~48.3

2939

45.8~50.4

3090

3×50

1×10

7×4

47.7~51.0

3909

51.5~55.0

4078

 

No. of cod×Nominal Area  mm2

MCP-0.66/1.14 Diameter and weight of cable

Power core

Earthing core

Earthing core

Diameter mm

Weight kg/km

A type

B type

3×35

1×6

47.8~51.0

53.2~58.7

3479

3×50

1×10

3×16/3

53.5~58.9

59.0~63.0

4608

3×70

1×16

3×25/3

58.9~63.0

63.8~70.2

5612

3×95

1×25

3×35/3

64.9~71.4

68.7~75.6

6971

 

No. of cod×Nominal Area mm2

MCP-1.9/3.3 Diameter and weight of cable

Power core

Earthing core

Earthing core

Diameter mm

Weight kg/km

A type

B type

3×35

1×16

3×16/3

52.1~56.8

60.0~63.0

3172

3×50

1×25

3×25/3

56.4~62.0

63.8~70.2

4087

3×70

1×35

3×35/3

62.7~69.0

69.0~75.9

4908

3×95

1×50

3×50/3

67.8~74.6

73.1~78.0

5896

 

■ Operating characteristics 

1. Rated voltage U0/U: 0.38/0.66kV, 0.66/1.14kV and 1.9/3.3kV

2. Permissible continuous operating temperature of conductor: Voltage 0.38/0.66kV 

and 0.66/1.14kV:65℃, 

Voltage 1.9/3.3kV:90℃

3. The Min. bending radius 6 times of the cable diameter 

4. Cable with yellow sheath does not permit to expose to sunlight for a long time

■ Technical Property

1. D.C. resistance and insulation resistance of power core at 20℃

Nominal cross sectional area 

of conductor  mm2

D.C. resistance of Power 

core conductor Ω/km

Insulation resistance of power core  MΩ.km

≤0.66/1.14kV 

1.9/3.3kV

16

≤1.24

≥120

——

25

≤0.795

≥120

——

35

≤0.565

≥100

≥380

50

≤0.393

≥100

≥350

70

≤0.277

≥80

≥320

95

≤0.210

≥80

≥280

       

 

2. Transition resistance, transition resistance of shielding layer should not be more than 3 kΩ.

3. Power core of 0.38/0.66kV cable should be undertaken work frequency test with 3.0kV of withstand voltage test for 5 min without breakdown.

Power core of 0.66/1.14kV cable should be undertaken work frequency test with 3.7kV of withstand voltage test for 5 min without breakdown.Power core of 1.9/3.3kV cable should be undertaken work frequency test with6.8kV of withstand voltage test for 5 min without breakdown.

 

■ Standard

MT818.3-1999,GB12972.3-91,MT386

Trailing coalcutter flexible cables with monitoring core 

and semiconducting screens for rated voltage of 0.66/1.44kV

Type

Name

Application

MCPJB-0.66/1.14

UCPJB-0.66/1.14

Trailing coalcutter braided cable with monitoring 

core and semiconducting screens

For power supply of coalcutters or 

similar equipments of rated 

voltage up to and including 0.66/1.14kV. 

The cable can be  directly used by trailing

MCPJR-0.66/1.14

CUPJR-0.66/1.14

Trailing coalcutter wrapped cable with monitoring core 

and semiconducting screens

For power supply of coalcutters or

 similar equipments 

of rated voltage up to and 

including 0.66/1.14kV.

But the cable 

should be laid in shield scraping belt.

■ Construction of cable

1. Power core conductor

2. Earthing core conductor

3. Insulation

4. Semi-conduct shield

5. Inner sheathed

6. Monitoring core

7. =being wrapped reinforced layer

#woven reinforced layer (can also be used for ground wire)

8. Outersheathed

■ Structure and size of cable

No. of cod×Nominal Area 

mm2

Diameter and weight of cable

MCPJR-0.66/1.14

MCPJB-0.66/1.14

Power core

Earthling core

Control core

Diameter 

mm

Weight 

kg/km

Diameter

 mm

Weight 

kg/km

3×35

1×16

3×2.5

40.0~44.5

3580

42.0~47.0

3635

3×50

1×25

3×2.5

45.5~50.5

4738

47.5~51.0

4802

3×70

1×35

3×2.5

51.5~55.0

5715

52.0~56.5

6210

3×95

1×50

3×2.5

56.0~61.5

7082

58.0~63.0

7113

Note:Nominal cross-sectional area of monitoring core conductor≥1.5 mm2,No reference insulation 

thickness of control core and monitoring core.   

■ Operating characteristics 

1. Raged voltage U0/U: 0.66kV/1.14kV 

2. Continuous operating temperature of conductor: 90℃

3. The Min. bending radius 15 times of the cable diameter. 

■ Technical Property

1. Insulation resistance of power core at 20℃

Nominal cross sectional area of conductor  mm2

Diameter resistance of power core  MΩ.km

35

≥350

50

≥320

70

≥280

95

≥100

2. Transition resistance of shielding layer or monitor layer≤500Ω.

3. Finished cable should undergo AC 50Hz 3.7kV voltage, 5 min test and is not to be punctured.

■ Standard

MT818.4-1999,GB12972.4-91,MT386

Flexible coalcutter cables with individual metallic screens 

for rated voltage up to and including 1.9/3.3kV

Type

Name

Application

MCPTJ-0.66/1.14

Flexible coalcutter cables 

with monitoring core 

and individual metallic screens

For power supply of coalcutters or

 similar equipments 

of rated voltage up to and including 0.66/1.14kV.

MCPT-1.9/3.3

UCPT-0.66/1.14

Rubber insulated coalcutter cable 

with individual monitoring screens

For power supply of coalcutters or 

similar equipments 

of rated voltage up to and including 1.9/3.3kV.

MCPTJ-1.9/3.3

Flexible coalcutter cables 

with monitoring 

core and individual metallic screens

For power supply of coalcutters or

 similar equipments 

of rated voltage up to and including 1.9/3.3kV.

■ Construction of cable

1. Power core conductor

2. Power core insulation

3. Metallic/Fiber woven shield

4. Earthing core conductor

5. Monitoring core conductor

6. Control core conductor

7. Monitoring core insulation

8. Control core insulation

9. Control core wrapped layer

10. Sheathed

■ Structure and size of cable

No. of cod×Nominal Area  mm2

  MCPTJ-0.66/1.14  Diameter and weight of cable

Power core

Earthing core

Monitoring core

Diameter mm

Weight kg/km

3×16

1×16

1×16

37.1~40.8

2420

3×25

1×16

1×16

41.7~45.9

2861

3×35

1×16

1×16

47.2~51.9

3507

3×50

1×25

1×25

51.5~56.2

4423

3×70

1×35

1×35

57.9~63.0

5919

3×95

1×50

1×50

65.1~71.6

7398

The insulated diameter fairly for monitoring core to power core.

 

No. of cod×Nominal Area  mm2

        MCPTJ-1.9/3.3   Diameter and weight of cable

Power core

Earthing core

Monitoring core

Diameter mm

    Weight kg/km

3×35

1×16

1×16

55.0~60.7

3930

3×50

1×25

1×25

57.8~63.0

5402

3×70

1×35

1×35

64.1~70.8

6837

3×95

1×50

1×50

69.2~76.2

8095

The insulated diameter fairly for monitoring core to power core.

 

No. of cod×Nominal Area  mm2

   MCPT-1.9/3.3   Diameter and weight of cable

Power core

Earthing core

Diameter mm

Weight kg/km

3×35

1×16

55.0~60.7

4302

3×50

1×25

57.8~63.0

5131

3×70

1×35

64.1~70.8

6504

3×95

1×50

69.2~76.2

7528

■ Operating characteristics 

1. Rated voltage U0/U:0.66/1.14kV and 1.9/3.3kV

2. Continuous operating temperature of conductor: 90℃

3. The Min. bending radius 6 times of the cable diameter.

■ Technical Property

1. D.C. resistance and insulation resistance of power core at 20℃

 

Nominal cross

 sectional area of conductor

mm2

D.C. resistance of 

power core

 conductor

Ω/km

Insulation resistance

 of power core  MΩ.km

D.C. resistance of ground wire with 

shield is parallel connection Ω/km

Rated Voltage

0.66/1.44kV

Rated Voltage

1.9/3.3kV

16

1.24

≥350

——

≤0.70

25

0.795

≥300

——

≤0.60

35

0.565

≥260

≥380

≤0.60

50

0.393

≥230

≥350

≤0.50

70

0.277

≥210

≥320

≤0.34

95

0.210

≥200

≥280

≤0.2

 

2. Power core of 0.66/1.14kV cable should be undertaken work frequency test with 3.7kV of withstand voltage test for 5 min without breakdown.

Power core 1.9/3.3kV cable should be undertaken work frequency test with 6.8kV of withstand voltage test for 5 min without breakdown.

3. Insulation line core undertaken insulation water absorbing test , the increasing rate of capacitance for 1~14d≤10% ,the increasing rate of capacitance for 7~14d≤3%.

 

■ Standard  MT818.5-1999,GB12972.5-91,MT386

Moveable flexible cables for rated voltage up to and including 0.66/1.14kV

Type

Name

Application

MY-0.38/0.66

UY-0.38/0.66

Moveable rubber sheathed 

flexible cable for coal mine

For power supply of various moveable 

excavators under well of 

rated voltage 0.38/0.66kV

MYE-0.38/0.66

Moveable elastomer 

sheathed flexible cable

For power supply of various moveable 

excavators under well of 

rated voltage 0.38/0.66kV

MYP-0.38/0.66

UYP-0.38/0.66

Moveable rubber sheathed 

flexible cable with screens

For power supply of various moveable 

excavators under well of 

rated voltage 0.38/0.66kV

MYPE-0.38/0.66

Moveable elastomer sheathed 

flexible cable with screens

For power supply of various moveable 

excavators under well of 

rated voltage 0.38/0.66kV

MYP-0.66/1.14

UYP-0.66/1.14

Moveable rubber sheathed 

flexible cable with screens

For power supply of various moveable 

excavators under well of 

rated voltage 0.66/1.14kV

MYPE-0.66/1.14

Moveable elastomer sheathed 

flexible cable with screens

For power supply of various moveable 

excavators under well of 

rated voltage 0.66/1.14kV

■ Construction of cable

1. Power core conductor

2. Filler

3. Insulation

4. Insulation screen

5. Earthing core conductor

6. Outersheathed

■ Structure and size of cable

    Number and nom. 

crosssection of 

conductors mm2

Diameter and 

weight of cable

Number and nom. 

cross-section of 

conductors mm2

Diameter and 

weight of cable

MY-0.38/0.66  MYE-0.38/0.66

MY-0.38/0.66  MYE-0.38/0.66

Diameter mm

Weight kg/km

Diameter mm

Weight kg/km

1×50

18.7~20.5

819

1×185

32.7~35.9

2504

1×70

20.9~23.0

1035

1×240

35.3~38.8

3169

1×95

24.2~26.6

1369

1×300

40.0~43.3

3936

1×120

26.4~29.0

1686

1×400

43.4~47.7

4995

1×150

30.1~33.1

2081

 

 

 

 

Number and nom. cross-section of conductors mm2

    Diameter and weight of cable

MY-0.38/0.66

MYE-0.38/0.66

MYP-0.38/0.66 

MYPE-0.38/0.66

Power core

Earthing core

Diameter mm

   Weight kg/km

Diameter mm

Weight kg/km

3×4

1×4

20.9~23.0

677

22.9~25.2

716

3×6

1×6

22.9~25.1

809

24.7~27.2

887

3×10

1×10

27.8~30.6

1252

29.7~32.7

1307

3×16

1×10

30.3~33.3

1427

32.2~35.4

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    1982

  • Total Annual:

    > 100,000,000

  • Employee Number:

    >1000

  • Ecer Certification:

    Active Member

Hebei New Baofeng Wire & Cable Co., Ltd. owns fixed capital of RMB 1.6 billion with 1100 staffs (among whom 86 are senior engineers and technicians, 230 are engineers and technicians). The Group Co. consists of 18 departments, 11 branches, 32 representative offices with its sales networks coveri... Hebei New Baofeng Wire & Cable Co., Ltd. owns fixed capital of RMB 1.6 billion with 1100 staffs (among whom 86 are senior engineers and technicians, 230 are engineers and technicians). The Group Co. consists of 18 departments, 11 branches, 32 representative offices with its sales networks coveri...

+ Read More

Get in touch with us

  • Reach Us
  • Hebei New Baofeng Wire & Cable Co.,Ltd
  • Jinghe Hi-tech Industrial Zone, Hejian City, Hebei province,China
  • http://www.nbf-powercable.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement