Packaging Details | steel |
Delivery Time | Negotiable |
Payment Terms | L/C,T/T.OA |
Place of Origin | Hebei,china(Mainland) |
Brand Name | New Baofeng |
View Detail Information
Explore similar products
High Quality PVC insulated fixed Laying Cable Wire, Low-voltage Electric Cable
PVC Insulated Fixed Laying Low-voltage Electric Cable with Excellent Thermal
3x1.5mm2 PVC Insulation Low - voltage Electric Cable For Switch Lighting
Aluminum Coppe conductor, PE PVC sheathed Electrical Low-voltage Electric Cable
Product Specification
Packaging Details | steel | Delivery Time | Negotiable |
Payment Terms | L/C,T/T.OA | Place of Origin | Hebei,china(Mainland) |
Brand Name | New Baofeng | ||
High Light | PVC Insulated Cable , Low Voltage Cable |
XLPE Insulated Electrical Power Cable Low-voltage
Quick Detail:
1)Insulation Material: XLPE
2) voltage rating: low voltage
3) Application: Industrial,power station, underground, industry
GB/T12706.1-2002, equivalent to IEC60502
This product is suitable for use in rated AC voltage (U0/U) 0.6/1kV system transmitting and distributing circuit.
It is far better than all property targets of PVC insulated power cable and has overcome
the shortcomings of physical and chemical cross-linkage, and completely reaches or surpasses
GB and IEC technical property value.
The allowed max .cable conductor work temperature is 90℃;urgent excess work temperature is
130℃ for short circuit(5s), max. conductor temperature is 250℃.
The environmental temperature for laying cable should be not less than 0℃. If laying under 0℃,
the cable should be preheated.
The cable bend radius for single core should be not less than 12 times of overall cable diameter;
for multi-core cable, not less than 10 times of overall cable diameter.
The current-carrying capacity is large and not limited by drop during laying .
Type |
Designation |
Application |
YJV |
Copper conductor , XLPE insulated and PVC sheathed Electrical cable |
For laying indoors, in tunnels or cable trench, unable to bear external mechanical forces. |
YJLV |
Aluminum conductor , XLPE insulated and PVC sheathed Electrical cable |
|
YJY |
Copper conductor , XLPE insulated and PE sheathed Electrical cable |
|
YJLY |
Aluminum conductor , XLPE insulated and PE sheathed Electrical cable |
|
YJV22 |
Copper conductor , XLPE insulated, steel tape armored and PVC sheathed Electrical cable |
Indoors, tunnels, cable canal, vertically burying and easy to corrode places, can bear mechanical pressure. |
YJLV22 |
Aluminum conductor , XLPE insulated, steel tape armored and PVC sheathed Electrical cable |
|
YJV23 |
Copper conductor , XLPE insulated, steel tape armored and PE sheathed Electrical cable |
|
YJLV23 |
Aluminum conductor , XLPE insulated, steel tape armored and PE sheathed Electrical cable |
|
YJV32 |
Copper conductor , XLPE insulated, steel wire armored and PVC sheathed Electrical cable |
Vertically laying, can bear mechanical pulling force, but not pressure. |
YJLV32 |
Aluminum conductor , XLPE insulated, steel wire armored and PVC sheathed Electrical cable |
|
YJV33 |
Copper conductor , XLPE insulated, steel wire armored and PE sheathed Electrical cable |
|
YJLV33 |
Aluminum conductor , XLPE insulated, steel wire armored and PE sheathed Electrical cable |
Type |
No. of cores |
Nominal cross-sectional area mm2 |
|
Copper Conductor |
Aluminum Conductor |
||
YJV YJY — YJV22 YJV23 |
— YJLV YJLY YJLV22 YJLV23 |
1* |
1.5~800 2.5~800 10~800 |
YJV YJY — YJV22 YJV23 YJV32 YJV33 |
— YJLV YJLY YJLV22 YJLV23 YJLV32 YJLV33 |
2 |
1.5~400 2.5~400 2.5~400 10~400 |
YJV YJY — YJV22 YJV23 YJV32 YJV33 |
— YJLV YJLY YJLV22 YJLV23 YJLV32 YJLV33 |
3 |
1.5~400 2.5~400 2.5~400 10~400 |
YJV YJY — YJV22 YJV23 YJV32 YJV33 |
— YJLV YJLY YJLV22 YJLV23 YJLV32 YJLV33 |
4 |
1.5~400 2.5~400 2.5~400 10~400 |
YJV YJY — YJV22 YJV23 — YJV32 YJV33 |
— YJLV YJLY — YJLV22 YJLV23 YJLV32 YJLV33 |
3+1 |
1.5~400 4~400 1.5~400 4~400 10~400 |
YJV YJY — YJV22 YJV23 — YJV32 YJV33 |
— YJLV YJLY — YJLV22 YJLV23 YJLV32 YJLV33 |
5 |
1.5~400 2.5~400 1.5~400 2.5~400 10~400 |
YJV YJY — YJV22 YJV23 — YJV32 YJV33 |
— YJLV YJLY — YJLV22 YJLV23 YJLV32 YJLV33 |
4+1 |
1.5~400 4~400 1.5~400 4~400 10~400 |
YJV YJY — YJV22 YJV23 — YJV32 YJV33 |
— YJLV YJLY — YJLV22 YJLV23 YJLV32 YJLV33 |
3+2 |
1.5~400 4~400 1.5~400 4~400 10~400 |
NOTE: The armored single-core cables are used for d. c. system only. As for a. c. system, non-magnetic armor material should be used, or magnetic isolation should be applied.
0.6/1kV 1-Core,XLPE insulated PVC/PE Sheathed Power Cable |
|||||||
Nominal cross-sectional area mm2 |
Diameter of conductor mm |
YJV YJLV YJY YJLY |
YJV22 YJLV22 YLV23 YJLV23 |
||||
Approx overall diameter mm |
Cable weight, max kg/km |
Approx overall diameter mm |
Cable weight, max kg/km |
||||
YJV YJY |
YJLV YJLY |
YJV22 YJY23 |
YJLY22 YJLY23 |
||||
1×1.5 |
0.7 |
5.6 |
52 |
— |
— |
— |
— |
1×2.5 |
0.7 |
6.0 |
65 |
50 |
— |
— |
— |
1×4 |
0.7 |
6.4 |
83 |
58 |
— |
— |
— |
1×6 |
0.7 |
7.0 |
106 |
69 |
— |
— |
— |
1×10 |
0.7 |
8.3 |
157 |
94 |
11.7 |
233 |
170 |
1×16 |
0.7 |
9.3 |
221 |
121 |
12.7 |
305 |
205 |
1×25 |
0.9 |
11.2 |
334 |
175 |
14.4 |
426 |
267 |
1×35 |
0.9 |
12.4 |
435 |
215 |
15.6 |
536 |
316 |
1×50 |
1.0 |
14.1 |
576 |
278 |
17.1 |
680 |
382 |
1×70 |
1.1 |
16.1 |
793 |
362 |
19.1 |
912 |
481 |
1×95 |
1.1 |
18.2 |
1066 |
468 |
21.0 |
1188 |
590 |
1×120 |
1.2 |
20.0 |
1321 |
565 |
22.8 |
1454 |
698 |
1×120* |
1.2 |
18.7 |
1275 |
539 |
21.5 |
1400 |
663 |
1×150 |
1.4 |
22.0 |
1606 |
677 |
24.8 |
1751 |
823 |
1×150* |
1.4 |
20.7 |
1584 |
658 |
23.5 |
1721 |
795 |
1×185 |
1.6 |
24.2 |
1977 |
813 |
27.0 |
2140 |
976 |
1×185* |
1.6 |
22.6 |
1868 |
763 |
25.4 |
2020 |
915 |
1×240 |
1.7 |
27.1 |
2548 |
1018 |
29.9 |
2729 |
1200 |
1×240* |
1.7 |
25.1 |
2399 |
952 |
27.9 |
2567 |
1121 |
1×300 |
1.8 |
29.7 |
3151 |
1232 |
32.7 |
3363 |
1445 |
1×300* |
1.8 |
27.5 |
3028 |
1172 |
30.5 |
3225 |
1369 |
1×400 |
2.0 |
33.1 |
3985 |
1531 |
38.1 |
4596 |
2142 |
1×400* |
2.0 |
30.9 |
3888 |
1478 |
35.9 |
4461 |
2050 |
1×500 |
2.2 |
36.8 |
4996 |
1902 |
41.8 |
5667 |
2574 |
1×500* |
2.2 |
34.5 |
4953 |
1861 |
39.5 |
5584 |
2492 |
1×630 |
2.4 |
41.1 |
6294 |
2372 |
46.3 |
7084 |
3132 |
1×630* |
2.4 |
38.5 |
6164 |
2299 |
43.7 |
6878 |
3031 |
1×800 |
2.6 |
45.7 |
7920 |
2592 |
50.9 |
8757 |
3789 |
*Compacted conductor
1. Conductor
2. Insulation
3. Sheath
0.6/1kV 2-Core,XLPE Insulated PVC/PE Sheathed Power Cable |
||||||||||
Nominal cross-sectional area mm2 |
Diameter of conductor mm |
YJV YJLV YJY YJLY |
YJV22 YJLV22 YJV23 YJLV23 |
YJV32 YJLV32 YJV33 YJLV33 |
||||||
Approx overall diameter mm |
Cable weight, max kg/km |
Approx overall diameter mm |
Cable weight, max kg/km |
Approx overall diameter mm |
Cable weight, max kg/km |
|||||
YJV YJY |
YJLV YJLY |
YJV22 YJV23 |
YJLV22 YJLV23 |
YJV32 YJV33 |
YJLV32 YJLV33 |
|||||
2×1.5 |
0.7 |
10.0 |
99 |
— |
— |
— |
— |
— |
— |
— |
2×2.5 |
0.7 |
10.8 |
127 |
95 |
12.6 |
218 |
187 |
— |
— |
— |
2×4 |
0.7 |
11.7 |
164 |
115 |
13.5 |
265 |
215 |
— |
— |
— |
2×6 |
0.7 |
12.7 |
214 |
139 |
14.5 |
325 |
250 |
— |
— |
— |
2×10 |
0.7 |
15.3 |
324 |
195 |
17.1 |
447 |
318 |
20.9 |
912 |
783 |
2×16 |
0.7 |
17.4 |
460 |
257 |
19.2 |
602 |
398 |
23.0 |
920 |
920 |
2×25 |
0.9 |
20.8 |
691 |
369 |
22.6 |
863 |
540 |
26.4 |
1156 |
1156 |
2×35 |
0.9 |
23.1 |
907 |
460 |
24.9 |
1099 |
651 |
28.7 |
1328 |
1328 |
2×50* |
1.0 |
19.6 |
1039 |
Company Details Bronze Gleitlager,Bronze Sleeve BushingsandGraphite Plugged Bushingsfrom Quality China Factory
Hebei New Baofeng Wire & Cable Co., Ltd. owns fixed capital of RMB 1.6 billion with 1100 staffs (among whom 86 are senior engineers and technicians, 230 are engineers and technicians). The Group Co. consists of 18 departments, 11 branches, 32 representative offices with its sales networks coveri... Hebei New Baofeng Wire & Cable Co., Ltd. owns fixed capital of RMB 1.6 billion with 1100 staffs (among whom 86 are senior engineers and technicians, 230 are engineers and technicians). The Group Co. consists of 18 departments, 11 branches, 32 representative offices with its sales networks coveri... Get in touch with us
Send Email