Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"Non Explosionproof Type High Precision Ozone Alarm Tester For Safe Clean Room","imgUrl":"https:\/\/img.ismap.com\/nimg\/ef\/59\/7cd2ffd971ded6940a95928e7b5c-200x200-1\/non_explosionproof_type_high_precision_ozone_alarm_tester_for_safe_clean_room.jpg","attrs":{"Brand Name":"YuanTe","Model Number":"YT-96H","Certification":"CE ISO9001-2015","Place of Origin":"China"}}
{"title":"IP68 H2s Gas Monitor 0-100ppm Small Size for Industrial Detection Data logger","imgUrl":"https:\/\/img.ismap.com\/nimg\/c7\/fe\/341026b1f499282ffce9cd395a93-200x200-1\/ip68_h2s_gas_monitor_0_100ppm_small_size_for_industrial_detection_data_logger.jpg","attrs":{"Brand Name":"Safegas","Model Number":"Minimeta","Certification":"ATEX\/EMC\/IECE","Place of Origin":"China"}}
{"title":"Portable High Accuracy H2O2 Single Gas Detector Hydrogen Peroxide Gas Detector","imgUrl":"https:\/\/img.ismap.com\/nimg\/ce\/22\/1f3c8cb60d733484247b1fa2a49f-200x200-1\/portable_high_accuracy_h2o2_single_gas_detector_hydrogen_peroxide_gas_detector_for_hospital_pharmaceutical_industry.jpg","attrs":{"Brand Name":"YuanTe","Model Number":"SKY6000-H2O2","Certification":"CNEX,ISO9001,CE","Place of Origin":"China"}}
{"title":"Portable N2 Single Gas Detector Nitrogen Gas Detector With Internal PTFE Layer","imgUrl":"https:\/\/img.ismap.com\/nimg\/d2\/b7\/c674c5127bd025f62f35aa78ffbe-200x200-1\/portable_n2_single_gas_detector_nitrogen_gas_detector_with_internal_ptfe_layer.jpg","attrs":{"Brand Name":"YuanTe","Model Number":"SKY6000-N2","Certification":"CNEX,ISO9001,CE","Place of Origin":"China"}}
{"title":"Fixed Type Single Gas Detector 0 - 1ppm O3 Gas Detector High Precision","imgUrl":"https:\/\/img.ismap.com\/nimg\/68\/51\/3bc34f182dfb9036bba2670e1e99-200x200-1\/fixed_type_single_gas_detector_0_1ppm_o3_gas_detector_high_precision.jpg","attrs":{"Brand Name":"YuanTe","Model Number":"YT-95H-O3","Certification":"CE CNEX ISO9001-2015","Place of Origin":"China"}}
{"title":"Portable Sulfur Hexafluoride SF6 Single Gas Detector With LCD Display For","imgUrl":"https:\/\/img.ismap.com\/nimg\/fe\/c0\/02343789196a5e144cb3cb79d112-200x200-1\/portable_sulfur_hexafluoride_sf6_single_gas_detector_with_lcd_display_for_electrical_areas.jpg","attrs":{"Brand Name":"YuanTe","Model Number":"SKY2000-SF6","Certification":"CNEX,ISO9001,CE","Place of Origin":"China"}}
{"title":"Fixed Helium He Gas Detector Single Gas Detector With 4 - 20ma And RS485 Signal","imgUrl":"https:\/\/img.ismap.com\/nimg\/04\/60\/bc78c05236d7b1c735c50787adef-200x200-1\/fixed_helium_he_gas_detector_single_gas_detector_with_4_20ma_and_rs485_signal_output.jpg","attrs":{"Brand Name":"YuanTe","Model Number":"YT-95H-He","Certification":"CE CNEX ISO9001-2015","Place of Origin":"China"}}
Non Explosionproof Type High Precision UK Sensor Ozone Alarm Tester For Safe Clean Room
Product overview
YT-96H-WH is designed specifically for disinfection fields such as pharmaceutical cleanrooms. This is an online monitoring fixed ozone detector. Adopting imported brand electrochemical principle sensors, it has small size, light weight, fast response, accurate detection, reliable operation, and convenient maintenance. 24V DC power supply, standard 4-20mA, RS485 signal and a set of relay signal outputs. Non explosion-proof design, required to be installed in non explosion-proof workplaces.
Product Advantages
All imported electrochemical principle sensors are used
Standard three wire 4-20mA analog signal, RS485 signal output
Compatible with various control boards, PLC, DCS and other control systems, enabling remote monitoring
Standard equipped with a set of relay signals that can control peripheral sound and light alarms, fans, solenoid valves, and other equipment
The upper software can achieve setting, calibration, and remote monitoring.
Specification
Detected gas:
Ozone, etc, according to customer's requirements.
Detection principle:
Electrochemical
Measure range:
0-1000ppb, 0-1ppm, 0-5ppm, 0-10ppm, 0-20ppm, 0-50ppm, 0-100ppm, etc, according to customer's requirements.
Resolution:
1ppb, 0.001ppm, 0.01ppm, 0.1ppm, 1ppm, etc, according to sensor and measure ranges.
Accuracy:
≤±1-2%F.S.
Response time:
≤30 seconds (T90)
Display:
Segment LCD
Shell material:
Flame Retardant Thermoplastic PS
Concentration unit:
ppm, mg/m3
Alarm mode(Optional):
Buzzer and light, high and low alarm values can be set by customer.
Signal output:
4-20mA, RS485, 1 set of relay output; 1-5VDC(optional)
Communication and data download:
With PC software, history data can be downloaded, stored, printed, and analyzed in computer (optional)
Installation method:
Wall-mounted
Power supply:
24VDC
Language:
English
Humidity:
0~95%RH (non-condensing)
Temperature:
-20℃~+50℃
Working pressure:
91~111kpa
Size:
80.2*145*62.2mm
Weight:
230g (without packaging)
Pictures
Package
Accessories & Configuration list
Standard accessories
1. One calibration cap
2. One fixed gas detector
3. A certificate of conformity
4. An instruction manual
Optional accessoires
1. Alarm light
2. 24V DC adapter
When using an ozone detector, the following points should be noted:
The Industrial Hygiene Standard formulated by the Ministry of Health in 1979 stipulates a safety standard of 0.15 ppm for ozone.
According to American standards, personnel can work continuously for 8 hours at a concentration of 0.1ppm. (Ozone concentration in general forest areas can reach 0.1ppm)
According to the International Ozone Association, professional indoor applications of ozone are allowed to work for 10 hours at a concentration of 0.1 ppm.
The concentration that causes certain reactions in personnel is 0.5-1ppm, and the allowable exposure time is 1.5 hours. Over time, workers may feel discomfort such as dry mouth.
Concentrations of 1-4ppm can cause coughing, with an allowable exposure time of 1 hour.
Concentrations of 4-10ppm can cause strong coughing, with an allowable exposure time of 20 minutes.
The half-life of ozone is 20-50 minutes, and the final decomposition product is oxygen, so it will not cause residual pollution to food.
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer,Distributor/Wholesaler,Exporter
Year Established:
2010
Total Annual:
5000000-8000000
Employee Number:
100~120
Ecer Certification:
Verified Supplier
Established in 2010, Shenzhen YuanTe Technology Co., Limited is a company that focuses on the design, production and sales of environmental monitoring equipment and system. With “gas detector” as the core product, we have completed production line and solutions according to differen... Established in 2010, Shenzhen YuanTe Technology Co., Limited is a company that focuses on the design, production and sales of environmental monitoring equipment and system. With “gas detector” as the core product, we have completed production line and solutions according to differen...