Payment Terms | L/C,T/T,D/P |
Supply Ability | 30 PCS per month |
Delivery Time | 30 days after order confirmed |
Packaging Details | Plywood case |
Accuracy | 0.05/0.02/0.01 |
Standard Meter | SZ03A-K6 / SZ03A-K8 |
Test voltage output | 24V – 288V or customized |
Test current output | 1mA – 100A or customized,Max.200A |
Frequency Range | 45Hz~65Hz |
Brand Name | GENY |
Model Number | YC1891D |
Certification | ISO, CE |
Place of Origin | CHINA |
View Detail Information
Explore similar products
YC1893D ThreePhase Energy Meter Testing System Custom OEM and ODM Services
Terminal Connection Meter Tester Yc1891d-6 Meter Test System Accurate Measuremen
0.02% Accuracy Electricity Meter Test Equipment Precise Single Phase
Three Phase Energy Meter Test Equipment Lab Electric Meter Testing Equipment
Product Specification
Payment Terms | L/C,T/T,D/P | Supply Ability | 30 PCS per month |
Delivery Time | 30 days after order confirmed | Packaging Details | Plywood case |
Accuracy | 0.05/0.02/0.01 | Standard Meter | SZ03A-K6 / SZ03A-K8 |
Test voltage output | 24V – 288V or customized | Test current output | 1mA – 100A or customized,Max.200A |
Frequency Range | 45Hz~65Hz | Brand Name | GENY |
Model Number | YC1891D | Certification | ISO, CE |
Place of Origin | CHINA |
1. Basic Error Testing: This function evaluates the fundamental accuracy of the electricity meters under various load conditions, providing a baseline for their performance.
2. Creep, Startup, and Dail Tests: These tests assess the meter's response to minimal load conditions, ensuring that they operate accurately even at low energy consumption levels.
3. Influence Quantities Testing: The YC1893D is capable of testing the impact of various factors such as voltage, frequency, and harmonics on the meter's performance, ensuring that the meters remain accurate under different operating conditions.
4. Harmonic Testing: The test system supports comprehensive harmonic output, including general harmonics, subharmonics, odd and even orders harmonic, as well as DC harmonic component testing. This ensures that the meters can accurately measure power quality in environments with complex waveforms.
Technical spec. | YC1893D-6 | YC1893D-12 | YC1893D-24 | YC1893D-48 |
Number of meter positions | 6 | 12 | 24 | 48 |
Accuracy | 0.05 / 0.02 | |||
Power Source | YCS-103-250 | YCS-103-600 | YCS-103-1200 | YCS-103-2500 |
Standard Meter | SZ03A-K6 / SZ03A-K8 | |||
Scanning Head | YCG-S Series | |||
Voltage | | |||
Test voltage output(Phase-Neutral) | 3x(24V~288V)(or customized) | |||
Power of the voltage output | Max. 3x100VA | Max. 3x250VA | Max. 3x500VA | Max. 3x1000VA |
Resolution | Better than 0.01% of full scale value of range | |||
Setting accuracy | Better than 0.05% at the final range value | |||
Stability | Better than 0.005% /h (integration time 150s) | |||
Load regulation from 0~max. load | Better than 0.01% | |||
Distortion factor | Better than 0.3% for linear resistance load | |||
Harmonic | 2nd~21st free programmable | |||
Current | | |||
Test current output | 3x(1mA~100A) | |||
Power of the current output | Max. 3x150VA | Max. 3x350VA | Max. 3x750VA | Max. 3x1500VA |
Resolution | Better than 0.01% of full scale value of range | |||
Setting accuracy | Better than 0.05% at the final range value | |||
Stability | Better than 0.005% /h (integration time 150s) | |||
Load regulation from 0~max. load | Better than 0.01% | |||
Distortion factor | Better than 0.3% for linear resistance load | |||
Harmonic | 2nd~21st free programmable | |||
Phase angle | | |||
Range | 0~360⁰ | |||
Resolution | 0.01⁰ | |||
Setting accuracy | 0.1⁰ | |||
Frequency | | |||
Range | 45Hz~65Hz | |||
Resolution | 0.01Hz | |||
Error display | | |||
Type of error display | Red LED | |||
Resolution of error displays | 8 digitals | |||
Other | | |||
Voltage supply | 3x220/380V±10%(or customized) 50/60Hz ±2Hz | |||
Ambient temperature | -10°C~+40°C | |||
Relative humidity | 35%~85% |
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
1987
Total Annual:
2,000,000-10,000,000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
Guangzhou GENY Electric Co. Ltd. is a leading manufacturer of energy meter test systems, whose predecessor is Guangzhou Yangcheng Science & Technology Enterprises Co., Ltd. which was established in 1987. We have been dedicated to the energy meter testing industry for over 30 years, and continuou... Guangzhou GENY Electric Co. Ltd. is a leading manufacturer of energy meter test systems, whose predecessor is Guangzhou Yangcheng Science & Technology Enterprises Co., Ltd. which was established in 1987. We have been dedicated to the energy meter testing industry for over 30 years, and continuou...
Get in touch with us
Leave a Message, we will call you back quickly!