Payment Terms | L/C,T/T,D/P |
Supply Ability | 30 PCS per month |
Delivery Time | 30 days after order confirmed |
Accuracy | 0.05 / 0.02 |
Standard Meter | SZ03A-K6 / SZ03A-K8/SZ01A-K3 |
Relative humidity | 35%~85% |
Ambient temperature | -10°C -- +40°C |
Brand Name | GENY |
Model Number | YC1893/1D |
Certification | ISO, CE |
Place of Origin | CHINA |
View Detail Information
Explore similar products
Professional Three-Phase Stationary Meter Test Bench for Electric Energy Meter
Accuracy 0.02% Energy Meter Test Bench 3 Phase With ICTs For Smart Meter
Yc1891d-12 Meter Test System Watt Hour Single Phase Energy Meter Test Bench
Three Wire Electric Meter Test Bench YC1893D-12 Electrical Meter Calibration
Product Specification
Payment Terms | L/C,T/T,D/P | Supply Ability | 30 PCS per month |
Delivery Time | 30 days after order confirmed | Accuracy | 0.05 / 0.02 |
Standard Meter | SZ03A-K6 / SZ03A-K8/SZ01A-K3 | Relative humidity | 35%~85% |
Ambient temperature | -10°C -- +40°C | Brand Name | GENY |
Model Number | YC1893/1D | Certification | ISO, CE |
Place of Origin | CHINA |
1. Nation-level utility companies
2. Governmental bureaus of metrology
3. Big energy meter manufacturers
| YC1891D-6 | YC1891D-12 | YC1891D-24 | YC1891D-48 |
Number of meter positions | 6 | 12 | 24 | 48 |
Accuracy | 0.05 | |||
Power Source | YCS-101-250 | YCS-101-600 | YCS-101-1200 | YCS-101-2500 |
Standard Meter | SZ01A-K3 | |||
MSVT | HJ200GL-6 | HJ200GL-12 | HJ200GL-24 | HJ200GL-48 |
QCD | D5 series | |||
Scanning Head | YCG-2 series | |||
Voltage | ||||
Test voltage output | 24V – 288V or customized | |||
Power of the voltage output | 100VA | 250VA | 500VA | 1000VA |
Resolution | Better than 0.01% of full scale value of range | |||
Setting accuracy | Better than 0.05% at the final range value | |||
Stability | Better than 0.005%/h (integration time 150 s) | |||
Load regulation from 0-max. load | Better than 0.01% | |||
Distortion factor | Better than 0.3% for linear resistance load | |||
Harmonics | 2nd – 21st free programmable | |||
Current | ||||
Test current output | 1mA – 100A or customized,Max.200A | 1mA – 100A | ||
Power of the current output | 150VA | 350VA | 750VA | 1500VA |
Resolution | Better than 0.01% of full scale value of range | |||
Setting accuracy | Better than 0.05% at the final range value | |||
Stability | Better than 0.005%/h (integration time 150 s) | |||
Load regulation from 0-max. load | Better than 0.01% | |||
Distortion factor | Better than 0.3% for linear resistance load | |||
Harmonics | 2nd – 21st free programmable | |||
Phase angle | ||||
Range | 0 -- 360° | |||
Resolution | 0.01° | |||
Setting accuracy | 0.1° | |||
Frequency | ||||
Range | 45Hz – 65Hz | |||
Resolution | 0.01Hz | |||
Error display | ||||
Type of error display | Red LED | |||
Resolution of the error displays | 8 digits | |||
| ||||
Voltage Supply | 220V±10% or customized 50/60Hz±2Hz | 3x220/380V±10% or customized 50/60Hz±2Hz | ||
Ambient temperature | -10°C -- +40°C | |||
Relative humidity | 35% -- 85% |
Technical spec. | YC1893D-6 | YC1893D-12 | YC1893D-24 | YC1893D-48 |
Number of meter positions | 6 | 12 | 24 | 48 |
Accuracy | 0.05 / 0.02 | |||
Power Source | YCS-103-250 | YCS-103-600 | YCS-103-1200 | YCS-103-2500 |
Standard Meter | SZ03A-K6 / SZ03A-K8 | |||
Scanning Head | YCG-S Series | |||
Voltage | | |||
Test voltage output(Phase-Neutral) | 3x(24V~288V)(or customized) | |||
Power of the voltage output | Max. 3x100VA | Max. 3x250VA | Max. 3x500VA | Max. 3x1000VA |
Resolution | Better than 0.01% of full scale value of range | |||
Setting accuracy | Better than 0.05% at the final range value | |||
Stability | Better than 0.005% /h (integration time 150s) | |||
Load regulation from 0~max. load | Better than 0.01% | |||
Distortion factor | Better than 0.3% for linear resistance load | |||
Harmonic | 2nd~21st free programmable | |||
Current | | |||
Test current output | 3x(1mA~100A) | |||
Power of the current output | Max. 3x150VA | Max. 3x350VA | Max. 3x750VA | Max. 3x1500VA |
Resolution | Better than 0.01% of full scale value of range | |||
Setting accuracy | Better than 0.05% at the final range value | |||
Stability | Better than 0.005% /h (integration time 150s) | |||
Load regulation from 0~max. load | Better than 0.01% | |||
Distortion factor | Better than 0.3% for linear resistance load | |||
Harmonic | 2nd~21st free programmable | |||
Phase angle | | |||
Range | 0~360⁰ | |||
Resolution | 0.01⁰ | |||
Setting accuracy | 0.1⁰ | |||
Frequency | | |||
Range | 45Hz~65Hz | |||
Resolution | 0.01Hz | |||
Error display | | |||
Type of error display | Red LED | |||
Resolution of error displays | 8 digitals | |||
Other | | |||
Voltage supply | 3x220/380V±10%(or customized) 50/60Hz ±2Hz | |||
Ambient temperature | -10°C~+40°C | |||
Relative humidity | 35%~85% |
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
1987
Total Annual:
2,000,000-10,000,000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
Guangzhou GENY Electric Co. Ltd. is a leading manufacturer of energy meter test systems, whose predecessor is Guangzhou Yangcheng Science & Technology Enterprises Co., Ltd. which was established in 1987. We have been dedicated to the energy meter testing industry for over 30 years, and continuou... Guangzhou GENY Electric Co. Ltd. is a leading manufacturer of energy meter test systems, whose predecessor is Guangzhou Yangcheng Science & Technology Enterprises Co., Ltd. which was established in 1987. We have been dedicated to the energy meter testing industry for over 30 years, and continuou...
Get in touch with us