China factories

China factory - Guangzhou GENY Electric Co., Ltd

Guangzhou GENY Electric Co., Ltd

  • China,Guangzhou
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China Accurate and Versatile Stationary Meter Test Equipment for Industrial Applicatio
China Accurate and Versatile Stationary Meter Test Equipment for Industrial Applicatio

  1. China Accurate and Versatile Stationary Meter Test Equipment for Industrial Applicatio
  2. China Accurate and Versatile Stationary Meter Test Equipment for Industrial Applicatio

Accurate and Versatile Stationary Meter Test Equipment for Industrial Applicatio

  1. MOQ:
  2. Price:
  3. Get Latest Price
Payment Terms L/C, T/T, D/P
Supply Ability 100/Year
Model NO. YC1891D
After-sales Service 3 Year
Warranty 1 Year
Application Electromagnetic Instrument
Power Electricity
Voltage Output 24V-300V(or Customized)
Current Output 1mA-120A/200A
Thermocouple (TC) No
Resistance-Temperature Detector (RTD) No
LCD Display With LCD Display
Customized Customized
Trademark GENY
Transport Package Plywood Case
Specification 10.7CBM
Origin China
HS Code 9030849000
Port Guangzhou, China
Brand Name GENY
Model Number YC1891D
Certification ISO, CE
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T, D/P Supply Ability 100/Year
Model NO. YC1891D After-sales Service 3 Year
Warranty 1 Year Application Electromagnetic Instrument
Power Electricity Voltage Output 24V-300V(or Customized)
Current Output 1mA-120A/200A Thermocouple (TC) No
Resistance-Temperature Detector (RTD) No LCD Display With LCD Display
Customized Customized Trademark GENY
Transport Package Plywood Case Specification 10.7CBM
Origin China HS Code 9030849000
Port Guangzhou, China Brand Name GENY
Model Number YC1891D Certification ISO, CE
Place of Origin CHINA
High Light Industrial Stationary Meter Test EquipmentVersatile Stationary Meter Test EquipmentAccurate Stationary Meter Test Equipment

Accurate and Versatile Stationary Meter Test Equipment for Industrial Applications

Specification :

 

  YC1891D-6 YC1891D-12 YC1891D-24 YC1891D-48
Number of meter positions 6 12 24 48
Accuracy 0.05
Power Source YCS-101-250 YCS-101-600 YCS-101-1200 YCS-101-2500
Standard Meter SZ01A-K3
MSVT HJ200GL-6 HJ200GL-12 HJ200GL-24 HJ200GL-48
QCD D5 series
Scanning Head YCG-2 series
Voltage
Test voltage output 24V – 288V or customized
Power of the voltage output 100VA 250VA 500VA 1000VA
Resolution Better than 0.01% of full scale value of range
Setting accuracy Better than 0.05% at the final range value
Stability Better than 0.005%/h (integration time 150 s)
Load regulation from 0-max. load Better than 0.01%
Distortion factor Better than 0.3% for linear resistance load
Harmonics 2nd – 21st free programmable
Current
Test current output 1mA – 100A or customized,Max.200A 1mA – 100A
Power of the current output 150VA 350VA 750VA 1500VA
Resolution Better than 0.01% of full scale value of range
Setting accuracy Better than 0.05% at the final range value
Stability Better than 0.005%/h (integration time 150 s)
Load regulation from 0-max. load Better than 0.01%
Distortion factor Better than 0.3% for linear resistance load
Harmonics 2nd – 21st free programmable
Phase angle
Range 0 -- 360°
Resolution 0.01°
Setting accuracy 0.1°
Frequency
Range 45Hz – 65Hz
Resolution 0.01Hz
Error display
Type of error display Red LED
Resolution of the error displays 8 digits
 
Voltage Supply

220V±10% or customized

50/60Hz±2Hz

3x220/380V±10% or customized

50/60Hz±2Hz

Ambient temperature -10°C -- +40°C
Relative humidity 35% -- 85%

 

Optimized Description:

Meter Test System Overview:

Our advanced meter test system is designed to measure a variety of meters, including mechanical, electronic mechanical, and electronic meters, with options for automatic, semi-automatic, or manual operation. It supports testing of single-phase meters with 1P2W configurations and offers a range of testing modes including active power, reactive power, and cross-connected reactive power.

 

Key Features:

MSVT capability for testing single-phase meters with I-P links.

Current output switch for optional calibration of 2-element meters.

Simultaneous measurement of meters with identical specifications but varying constants.

Automatic rotor mark positioning for mechanical meters, enhancing efficiency.

Capabilities for starting tests and creeping tests.

Comprehensive protection against overload, short circuits, and open current circuits.

Simplified control with synchronized scanning heads.

Durable aluminum alloy construction for lightweight, strong, and corrosion-resistant design.

User-friendly Windows 2000/XP/7/8/10 compatible software with modules for error testing, harmonic analysis, demand testing, and influence testing.

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Seller

  • Year Established:

    1987

  • Total Annual:

    2,000,000-10,000,000

  • Employee Number:

    50~100

  • Ecer Certification:

    Verified Supplier

Guangzhou GENY Electric Co. Ltd. is a leading manufacturer of energy meter test systems, whose predecessor is Guangzhou Yangcheng Science & Technology Enterprises Co., Ltd. which was established in 1987. We have been dedicated to the energy meter testing industry for over 30 years, and continuou... Guangzhou GENY Electric Co. Ltd. is a leading manufacturer of energy meter test systems, whose predecessor is Guangzhou Yangcheng Science & Technology Enterprises Co., Ltd. which was established in 1987. We have been dedicated to the energy meter testing industry for over 30 years, and continuou...

+ Read More

Get in touch with us

  • Reach Us
  • Guangzhou GENY Electric Co., Ltd
  • ROOM 107, 1ST FLOOR, No. 602 GUANGSHAN ER ROAD, TIANHE DISTRICT, GUANGZHOU, CHINA POSTCODE: 510663
  • https://www.meter-testsystem.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement