China factories

China factory - Changsha GOMECY Electronics Limited

Changsha GOMECY Electronics Limited

  • China,Beijing ,Beijing
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China 10600nm Fractional CO2 Laser Machine For Skin Resurfacing Scar Removal Wrinkle
China 10600nm Fractional CO2 Laser Machine For Skin Resurfacing Scar Removal Wrinkle

  1. China 10600nm Fractional CO2 Laser Machine For Skin Resurfacing Scar Removal Wrinkle
  2. China 10600nm Fractional CO2 Laser Machine For Skin Resurfacing Scar Removal Wrinkle
  3. China 10600nm Fractional CO2 Laser Machine For Skin Resurfacing Scar Removal Wrinkle
  4. China 10600nm Fractional CO2 Laser Machine For Skin Resurfacing Scar Removal Wrinkle
  5. China 10600nm Fractional CO2 Laser Machine For Skin Resurfacing Scar Removal Wrinkle
  6. China 10600nm Fractional CO2 Laser Machine For Skin Resurfacing Scar Removal Wrinkle

10600nm Fractional CO2 Laser Machine For Skin Resurfacing Scar Removal Wrinkle

  1. MOQ: 1
  2. Price: USD 5299~5899
  3. Get Latest Price
Payment Terms T/T, Western Union, MoneyGram
Supply Ability 500 pcs per month
Delivery Time 5-7 days
Packaging Details Aluminum box
product name Fractional CO2 Laser
technology Medical CO2 Laser Machine
function Dermatology CO2 Laser
Working Mode Single pulse, Continuous pulse, Repeated pulse
Laser Type Metal Tube
Laser Wavelength 10600nm
Output Power 60W
Input Power 450VA
Operation Modes Pulsed, Ultra Pulsed, Continuous
Pulse Width 0.02–0.99s
Pulse Duration 1–100μs
Scan Patterns Triangle, Square, Rectangle, Diamond, Line, Round
Beam Divergence 4mrad
Focused Spot Diameter 120–240μm
Aiming Beam Infrared Ray (630–650nm, <5mW)
Beam Delivery 7-joint articulated arm, 360° rotation
Cooling System Internal circulation cooling
Display Screen True color LCD touch screen
Operation System Microcomputer control
Input Voltage AC220V ±10%, 50Hz
Probes Scanner probe, Vaginal probe, Surgical probe
Brand Name GOMECY
Model Number GMS C5 Verticle
Certification CE
Place of Origin Beijing

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union, MoneyGram Supply Ability 500 pcs per month
Delivery Time 5-7 days Packaging Details Aluminum box
product name Fractional CO2 Laser technology Medical CO2 Laser Machine
function Dermatology CO2 Laser Working Mode Single pulse, Continuous pulse, Repeated pulse
Laser Type Metal Tube Laser Wavelength 10600nm
Output Power 60W Input Power 450VA
Operation Modes Pulsed, Ultra Pulsed, Continuous Pulse Width 0.02–0.99s
Pulse Duration 1–100μs Scan Patterns Triangle, Square, Rectangle, Diamond, Line, Round
Beam Divergence 4mrad Focused Spot Diameter 120–240μm
Aiming Beam Infrared Ray (630–650nm, <5mW) Beam Delivery 7-joint articulated arm, 360° rotation
Cooling System Internal circulation cooling Display Screen True color LCD touch screen
Operation System Microcomputer control Input Voltage AC220V ±10%, 50Hz
Probes Scanner probe, Vaginal probe, Surgical probe Brand Name GOMECY
Model Number GMS C5 Verticle Certification CE
Place of Origin Beijing

10600nm Fractional CO2 Laser Machine For Skin Resurfacing Scar Removal Wrinkle Reduction And Dermatology TreatmentsGynecology CO2 Laser System

What is Fractional CO₂ Laser Technology?

The Fractional CO₂ Laser System is a high-precision medical and aesthetic device that emits 10600nm wavelength infrared laser energy, which is strongly absorbed by water molecules in biological tissues. Because human skin, mucosa, and soft tissue contain a high percentage of water, this wavelength is highly effective for controlled vaporization, coagulation, and thermal stimulation.

  • Fractional mode: The laser beam is divided into thousands of microscopic columns called microthermal zones (MTZs). These zones create precise damage to targeted tissue while leaving surrounding areas intact, promoting rapid healing, collagen remodeling, and skin rejuvenation.

  • Continuous and ultra-pulsed mode: Provides precise cutting, vaporization, and coagulation for minor surgical procedures. Ultra-pulsed mode allows high peak power in extremely short pulses, reducing thermal damage to surrounding tissue and minimizing patient downtime.

  • Thermal stimulation mechanism: The laser penetrates the epidermis and dermis, inducing collagen contraction and neocollagenesis (new collagen formation). This tightens loose skin, reduces wrinkles, and improves skin texture and elasticity.

  • Gynecology applications: Using specialized vaginal probes, fractional CO₂ laser stimulates mucosal regeneration, improves tissue hydration, elasticity, and vaginal health, supporting intimate wellness treatments.

  • Skin and soft tissue remodeling: Micro-ablation and heat stimulation also trigger the body’s natural repair mechanisms, promoting vascular remodeling, scar reduction, and improved pigmentation.

Advantages of fractional CO₂ laser technology:

  1. Controlled micro-damage: Targets specific tissue depth without harming surrounding areas.

  2. Minimal downtime: Rapid healing due to fractional microthermal zones.

  3. Versatile treatment: Effective for dermatology, minor surgery, and gynecology.

  4. Collagen stimulation: Induces long-term skin tightening and rejuvenation.

  5. Precision: Adjustable scan patterns, spot size, pulse width, and energy allow customized treatment for various clinical indications.

This advanced laser technology combines precision ablation, thermal coagulation, and fractional delivery to achieve superior clinical results while maintaining patient safety and comfort.

Application Range

The CO₂ Laser System is designed for multiple clinical and aesthetic purposes, including:

  • Skin resurfacing and rejuvenation

  • Wrinkle and fine line reduction

  • Scar revision (acne scars, surgical scars, trauma scars)

  • Pigmentation and age spot treatment

  • Vaginal tightening and mucosal rejuvenation

  • Minor dermatological surgery (nevus, papilloma, keratosis removal)

  • Soft tissue cutting with minimal bleeding

Product Attributes

Parameter Specification
Working Mode Single pulse, continuous pulse, repeated pulse
Output Power 60W
Input Power 450VA
Laser Type Metal tube
Laser Wavelength 10600nm
Scan Patterns Triangle / Square / Rectangle / Diamond / Line / Round
Beam Divergence Angle 4mrad
Focused Spot Diameter 120–240μm
Pulse Width 0.02–0.99s
Pulse Duration 1–100μs
Aiming Beam 630–650nm, <5mW infrared ray
Beam Delivery 7-joint articulated arm, 360° rotation
Cooling System Internal circulating coolant
Display Screen True color touch LCD
Operation System Microcomputer control
Input Voltage AC220V ±10%, 50Hz
Probes Scanner probe, vaginal probe, surgical probe

Product Details

  • Multi-functional probes: Includes scanner probe for fractional resurfacing, vaginal probe for gynecology treatments, and surgical probe for precise dermatological procedures.

  • Smart scanning patterns: Multiple customizable shapes allow physicians to adapt treatment for various indications.

  • Efficient cooling: Internal coolant ensures consistent performance and longer device lifespan.

  • User-friendly design: High-definition LCD screen and microcomputer control enable easy parameter adjustments.

  • Flexible delivery system: 7-joint articulated arm ensures stable energy transmission with high accuracy.

How to Perform Fractional CO₂ Laser Treatment?

Step 1. How to prepare the patient before treatment
The doctor conducts a consultation, evaluates skin condition or gynecological needs, reviews medical history, and sets clear treatment goals. Patients should avoid sun exposure and irritating skincare before the session.

Step 2. How to prepare the treatment area
Clean the skin thoroughly and disinfect the treatment site. Apply topical anesthesia if required to minimize discomfort.

Step 3. How to set the parameters of the CO₂ laser
Adjust the energy level, scanning pattern, pulse mode, and spot size according to the specific indication, such as skin resurfacing, scar revision, or gynecology treatment.

Step 4. How to apply the laser correctly
Use the appropriate probe (scanner, vaginal, or surgical) and move it evenly across the targeted area. Deliver energy in controlled pulses to create fractional microthermal zones or precise surgical incisions.

Step 5. How to cool the skin after laser application
Immediately apply a cold compress, soothing gel, or cooling mask to reduce redness, swelling, and discomfort.

Step 6. How to provide post-treatment care instructions
Guide the patient on daily aftercare: keep the area clean, moisturized, and protected with sunscreen. Avoid hot baths, strenuous exercise, and sun exposure for several days. Follow-up sessions may be recommended for best results.

Pre-treatment Precautions

  • Avoid excessive sun exposure or tanning at least 2 weeks before treatment.

  • Discontinue use of irritating skincare products (e.g., acids, retinoids) 5–7 days prior.

  • Ensure the treatment area is free from open wounds or infections.

  • Patients with a history of keloid formation should inform the physician.

  • Remove all makeup or skincare products before starting the procedure.

Post-treatment Care

  • Expect temporary redness, swelling, or mild discomfort lasting 1–3 days.

  • Keep the treated area clean and moisturized with gentle products.

  • Avoid direct sunlight; apply broad-spectrum sunscreen (SPF 30+) daily.

  • Do not pick or scratch peeling skin during the healing process.

  • Refrain from strenuous exercise, saunas, or hot baths for 3–5 days.

  • Follow the recommended follow-up sessions for optimal results.

Contraindications

  • Pregnancy or breastfeeding

  • Active skin infections (bacterial, viral, or fungal)

  • Severe systemic diseases (e.g., uncontrolled diabetes, cardiovascular issues)

  • Photosensitive conditions or medications

  • Patients with pacemakers or other implantable electronic devices

  • History of abnormal wound healing or keloid formation

Gynecology CO2 Laser System

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Seller

  • Year Established:

    2006

  • Total Annual:

    10,000,000-50,000,000

  • Employee Number:

    50~100

  • Ecer Certification:

    Verified Supplier

Changsha GOMECY Electronic Co., Ltd was founded in 2006. Specializing in the production of Diode laser, IPL, DPL, E-light, SHR, OPT, Fractional Co2 laser, Er: Yag, Er: Glass, Picolaser, 980nm+1470nm laser, ems body slimming, Velabody, Cryo weight loss equipment, magneto near infrared, tecar, shockwa... Changsha GOMECY Electronic Co., Ltd was founded in 2006. Specializing in the production of Diode laser, IPL, DPL, E-light, SHR, OPT, Fractional Co2 laser, Er: Yag, Er: Glass, Picolaser, 980nm+1470nm laser, ems body slimming, Velabody, Cryo weight loss equipment, magneto near infrared, tecar, shockwa...

+ Read More

Get in touch with us

  • Reach Us
  • Changsha GOMECY Electronics Limited
  • Block A, 1/F Jinri Science Park, No. 26 Jinyuan Road, Daxing District,Beijing, China
  • https://www.gomecy.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement