Output Power | 24kw |
Input Current | 42.9A/Phase |
Noise | ≤65dB |
Input AC | AC 380V ±15%/50/60±5Hz |
Efficiency Of Charge And Discharge | >85% |
Storage Environment Temperature | -20ºC~50ºC |
Protection Level | IP20 |
Number Of Channels | 4 |
Dimensions(W*D*H)(mm) | 600*800*1300(mm) |
Brand Name | Haida |
Model Number | HD-H213 |
Certification | CE,,ISO |
Place of Origin | China |
View Detail Information
Explore similar products
High Voltage And High Current Lithium Battery Test System For New Energy Battery
High Voltage Battery Pack Testing System 750V/2000V
PCB Battery Protection Board Testing System Power Battery Pack Protection Board
Finished / Semi-Finished Power Battery Testing System Battery Test Machine
Product Specification
Payment Terms | L/C, T/T, D/A, D/P, Western Union, MoneyGram | Supply Ability | 300 Sets per Month |
Delivery Time | 20 days after order confirmed | Packaging Details | each set protected with resin fiber and PP film, then put into Strong wooden case with operation man |
Output Power | 24kw | Input Current | 42.9A/Phase |
Noise | ≤65dB | Input AC | AC 380V ±15%/50/60±5Hz |
Efficiency Of Charge And Discharge | >85% | Storage Environment Temperature | -20ºC~50ºC |
Protection Level | IP20 | Number Of Channels | 4 |
Dimensions(W*D*H)(mm) | 600*800*1300(mm) | Brand Name | Haida |
Model Number | HD-H213 | Certification | CE,,ISO |
Place of Origin | China | ||
High Light | Battery Pack Module Charge Discharge Equipment ,EV Battery Life Cycle Testing Equipment |
Battery Pack Module Charge and Discharge EV Battery Life Cycle Testing System
Description:
Lithium batteries for electric vehicles
Lithium battery for electric bicycle
Energy storage lithium battery
Input AC | AC 380V ±15%/50/60±5Hz | ||||||||||
Output Power | 24 | KW | |||||||||
Input Current | 42.9 | A/Phase | |||||||||
Input Power | 28.2 | KW | |||||||||
Voltage | CV output range | 3~60V | |||||||||
Min discharge voltage | 3 | V | |||||||||
Accuracy | ±(0.02% of FS+0.02% of RD) | ||||||||||
Stability | ± 0.1% of FS | ||||||||||
Current | Output range/channel | 0.5A~100A | |||||||||
Accuracy | ±(0.05% of FS+0.05% of RD) | ||||||||||
CV cut-off current | 0.2A | ||||||||||
Stability | ± 0.1% of FS | ||||||||||
Power | Output power/channel | 6KW | |||||||||
Stability | ±0.2% of FS | ||||||||||
Time | Current response time | Max rising time: 5ms (10% to 90% or 90% to 10%) | |||||||||
Working step time | ≤(365*24)h/step, Time format-00:00:00.000(h,m,s,ms) | ||||||||||
Data record | Data record conditions | Min data record interval:10ms (connected with AUX channel:100ms) | |||||||||
Min voltage change:0.12V | |||||||||||
Min current change:0.2A | |||||||||||
Frequency | 100Hz (connected with AUX channel:10Hz) | ||||||||||
Charge | Charge mode | Constant current, Constant voltage, Constant current and voltage, Constant power | |||||||||
Cut-off condition | Main channel:Voltage, Current, ΔTime, Capacity,-ΔV | ||||||||||
Discharge | Discharge mode | Constant current, Constant power, Constant resistance | |||||||||
Cut-off condition | Main channel:Voltage, Current, ΔTime, Capacity | ||||||||||
Pulse Mode | Charge | Constant current, Constant power | |||||||||
Discharge | Constant current, Constant power | ||||||||||
Min pulse width | 100ms | ||||||||||
Pulse cycles | up to 32 | ||||||||||
Chg and Dischg switch | Supported | ||||||||||
Cut-off condition | Voltage, Time | ||||||||||
Simulation | Charge | Constant current, Constant power | |||||||||
Discharge | Constant current, Constant power | ||||||||||
Cut-off condition | Time,Line number | ||||||||||
Continuous switching Chg and Dischg | One simulation step can realize continuous switching from charging to discharging | ||||||||||
Limit step number | 1 million | ||||||||||
Cycle | Max cycles | 65535 | |||||||||
Max steps | 254 | ||||||||||
Cycle nest | 3 | ||||||||||
Protection | Power-off data protection | ||||||||||
Off-line operation mode | |||||||||||
User-defined protection conditions, such as upper and lower limited current/voltage, delay time, temperature, etc. | |||||||||||
Efficiency of Charge and discharge | >85% | ||||||||||
Protection level | IP20 | ||||||||||
Channels parallel | supported, Parallel channels do not support pulse and simulation testing | ||||||||||
Channels feature | Independent pairs of closed loop for constant | ||||||||||
Energy feedback | The discharge energy can be fed back to the grid | ||||||||||
Channels control mode | Independent control | ||||||||||
Noise | ≤65dB | ||||||||||
Database | MySQL | ||||||||||
Communicatin | TCP/IP | ||||||||||
Data export | EXCEL,TXT,CSV,PDF,Plot/Graph | ||||||||||
Disk drive | 500GB | ||||||||||
Operating system | Windows 7/8/10 64 bit | ||||||||||
Communication port | Ethernet port, CAN communication supports communication with BMS to obtain cell voltage and temperature in BMS | ||||||||||
Items | Values | ||||||||||
Number of channels | 4 | ||||||||||
Dimensions(W*D*H)(mm) | W*D*H:600*800*1300(mm) | ||||||||||
Working Environment requirement | |||||||||||
Items | Values | ||||||||||
Operation environment temperature | -10ºC~45ºC(When the temperature is 25±10ºC, the measurement accuracy is guaranteed: accuracy drift 0.005% of FS /ºC) | ||||||||||
Storage environment temperature | -20ºC~50ºC | ||||||||||
Operation environment humidity | ≤70% RH(no moisture condensation) | ||||||||||
Storage environment humidity | ≤80% RH(no moisture condensation) |
Other models (Voltage and Current) | |||||
60V20A | 60V30A | 60V50A | 60V60A | 60V100A | 60V120A |
60V400A | 60V240A | 120V50A | 120V100A | 120V200A | 120V400A |
200V50A | 500V100A | 200V200A | 400V200A | 750V500A | 800V600A |
Machine equips Charge and Discharge Port or Discharge voltage below 0V is Optional |
Details
Why choose us?
1.Design & Production : Solution Consultation for each order
Recommend the most cost -performance machine
Research & Develop the suitable one for Special- designed Model.
2.Shipping & Delivery: One-Stop Service
Production- Deliver to your door - Installation & Training- Technical Support
3.Warranty
1 year warranty with lifetime technology support
4.After-Sale Service
React within 2 Hours
Video inspection & on-site service combined
FAQ
Q: How about your warranty?
Q: What is the order process?
Q: Can we visit your factory before order?
Q: Do you accept customization service?
Description:
BMS battery management testing system is used for parameter calibration, verification, and testing during the developm
Company Details
Business Type:
Manufacturer,Seller
Year Established:
2004
Total Annual:
$ 5 Million-US$ 10 Million
Employee Number:
200~300
Ecer Certification:
Verified Supplier
.gtr-container-7f8d9e { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 20px; max-width: 1200px; margin: 0 auto; box-sizing: border-box; } .gtr-container-7f8d9e p { font-size: 14px; margin-bottom: 1e... .gtr-container-7f8d9e { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 20px; max-width: 1200px; margin: 0 auto; box-sizing: border-box; } .gtr-container-7f8d9e p { font-size: 14px; margin-bottom: 1e...
Get in touch with us
Leave a Message, we will call you back quickly!