Payment Terms | T/T in advance,L/C |
Supply Ability | 50 sets/month |
Delivery Time | 15 working days |
Brand Name | KINGSINE |
Model Number | K3163i |
Certification | ISO9001,CE |
Place of Origin | China |
View Detail Information
Explore similar products
High Precision KFA310 Mini Protection Relay Tester Multi-Functional
K3063i GOOSE Message Analysis Relay Protection Tester Show GOOSE Control Block
K3166i Protective Relay Tester / Protection Relay Test Equipment
High Fidelity Protection Relay Testing / 51 Overcurrent Relay K3040
Product Specification
Payment Terms | T/T in advance,L/C | Supply Ability | 50 sets/month |
Delivery Time | 15 working days | Brand Name | KINGSINE |
Model Number | K3163i | Certification | ISO9001,CE |
Place of Origin | China | ||
High Light | K31 Series Relay Protection Tester ,Secondary Injection Test Equipment K3163i |
All-in-One design, Integrated IEC61850 SV & GOOSE, 6I+4V analog channels output, Inbuilt
GPS and IRIG-B, and other advance functions.
◆ Complied IEC61850-9-1, IEC61850-9-2, IEC60044-7/8, etc
◆100/1000Mbit Fiber port for SMV and GOOSE simulations
◆6x35A & 4x310V independent high burden output channels
◆13 channels independent low-level signal outputs
◆ AC/DC measurement (8 channels inputs, 0.1 class, 0-600V/0-5A, auto range)
◆ Transducer calibration (0.02 class)
◆ Energy meter calibration (Mechanical & Electronic meters)
◆ Transient play back up to 3KHz
◆ Lightweight, <18Kg
◆ Fully function KRT software testing modules
◆ 3-Years guarantee of free repair and life-long maintenance
◆ Free software upgrade
Ordering Ref.
Model | Current Outputs | Voltage Outputs |
K3166 | 6×35A @ 450VA max / 3×70A @ 850VA max | 7×130V @ 75VA max |
K3166i | 6×35A @ 450VA max / 3×70A @ 850VA max | 7×310V @ 90VA max |
K3163 | 6×35A @ 450VA max / 3×70A @ 850VA max | 4×130V @ 75VA max |
K3163i | 6×35A @ 450VA max / 3×70A @ 850VA max | 4×310V @ 124VA max |
K3130 | 3×35A @ 450VA max | 4×130V @ 75VA max |
K3130i | 3×35A @ 450VA max | 4×310V @ 124VA max |
Able of what K31 series can test
Items | ANSI® No. |
IEC61850 numerical IEDs relay & merge unit | |
Distance protection relay | 21 |
Synchronising or synchronism-check relays | 25 |
Undervoltage relays | 27 |
Directional Power relays | 32 |
Undercurrent or underpower relays | 37 |
Negative sequence overcurrent relays | 46 |
Overcurrent/ground fault relays | 50 |
Inverse time overcurrent/ground fault relays | 51 |
Power factor relays | 55 |
Overvoltage relays | 59 |
Voltage or current balance relays | 60 |
Directional overcurrent relays | 67 |
Directional ground fault relays | 67N |
DC overcurrent relays | 76 |
Phase-angle measuring or out-of-step protection relays | 78 |
Automatic reclosing devices | 79 |
Frequency relays | 81 |
Motor overload protection relays | 86 |
Differential protection relays | 87 |
Directional voltage relays | 91 |
Voltage and power directional relays | 92 |
Tripping relays | 94 |
Voltage regulating relays | |
Overimpedance relays, Z> | |
Underimpedance relays, Z | |
Time-delay relays |
Characteristic
◆ 10 Channels (6x35A & 4x310V) outputs, Each output channels are independent and simultaneous
control of magnitude, Phase angle and frequency values, able to inject DC, AC sine wave and up to
20x harmonics.
◆ Variable battery simulator, DC 0-350V, 140Watts max.
◆ 13 Low-level channels outputs up to 8Vac/10Vdc max.
◆ 0-600V / 0-5A AC/DC measurement in 0.1 class.
◆ Graphical test modules and templates for testing of various relays
◆ Quick relay testing facility in Manual mode
◆ Shot/Search/Check, Point & Click testing
◆ RIO/XRIO import & export facility
◆ Switch on to fault test(SOTF)
◆ Power system model for dynamic testing
◆ Inbuilt GPS and IRIG-B sync end-to-end testing
◆ Online Vector display
◆ Automatic test results assume
◆ Automatic test report creation
◆ Anti-clipping detect, Wrong wiring connect alarm and self-protect, overload and overheat protection
Parameters
Voltage Outputs | ||||
Output Range & Power | 4×310 V ac (L-N) | 124 VA max each | ||
2×620 V ac (L-L) | 248 VA max each | |||
3×350 V dc (L-N) | 140 W max each | |||
Accuracy |
AC: <0.03%Rd+0.01Rg Typ.
<0.07%Rd+0.03Rg Guar.
|
|||
DC: ±10mV @ <5V, ±0.5% @ ≥5V | ||||
Resolution | 1mV | |||
Distortion | <0.05%Typ. / <0.1% Guar. | |||
Current Outputs | ||||
Output Range & Power | 6×35A ac (L-N) | 450 VA max each | ||
3×70A ac (2L-N) | 850 VA max each | |||
1×100A ac (6L-N) | 1200 VA max | |||
3×20A dc (L-N) | 300W max each | |||
Accuracy |
AC: <0.05%Rd+0.02Rg Typ.
<0.15%Rd+0.05Rg Guar.
|
|||
DC: ±5mA @ <1A, ±0.5% @ ≥1A | ||||
Resolution | 1mA | |||
Distortion | <0.05%Typ. / <0.1% Guar. | |||
13 Low-Level Channel Outputs | ||||
Quantity | 13 Channels, 16 pin aviation socket | |||
Voltage Outputs Range | AC 0~8V, DC 0~10V | |||
Current Outputs Range | Nominal 2mA, 10mA max transient | |||
Output Power | ≥0.5VA | |||
Accuracy |
(0.01~0.8 Vrms):<0.05% Typ. / <0.1% Guar.
(0.8~8 Vrms): <0.02% Typ. / <0.05% Guar.
|
|||
Resolution | 0.25mV | |||
Distortion(THD%) | <0.05% Typ. / <0.1% Guar. | |||
Frequency & Phase Angle | ||||
Frequency Range | DC~1KHz, 3KHz transient | |||
Frequency Accuracy | ±1ppm | |||
Frequency Resolution | 0.001 Hz | |||
Phase Range | -360°~360° | |||
Phase Accuracy | <0.05° Typ. / <0.1° Guar. 50/60Hz | |||
Phase Resolution | 0.001° | |||
IEC61850 Fiber & GOOSE Ethernet Ports (Optional Function) | ||||
Fiber Ports |
2 x 100Base-FX Full Duplex, LC type
(Optional to 10/100Mbit, Ethernet RJ45 type)
|
|||
Fiber Type | 62.5/125um (Multiple optical fiber, Orange Red) | |||
Wavelength | 1310nm | |||
Transmit Distance | >1Km | |||
Indicator |
Spd Green(light): Valid connection
Link/Act Yellow(Blinking): Data exchanging
|
|||
Note: All hardware of this module are ready for active | ||||
Aux. DC Voltage Source (Battery simulator) | ||||
Range | 0~350V @ 140W max | |||
Accuracy | 0.5%Rg Guar. | |||
Binary Input | ||||
Quantity | 8pairs | |||
Type | wet/dry, measurement | |||
Threshold | 10~600Vdc or potential free, Programmable | |||
Time resolution | 100us | |||
Debounce time | 0~25ms (Software Controlled) | |||
Time range | Infinite | |||
Time errors | ±1ms @ 0.001~1s, ±0.1% @ >1s | |||
Galvanic isolation | 4 isolated with each 2 pairs | |||
Binary Output (Relay Type) | ||||
Quantity | 4pairs | |||
Type |
Potential free relay contacts, software controlled
|
|||
Break Capacity AC | Vmax: 400Vac / Imax:8A / Pmax:2500VA | |||
Break Capacity DC | Vmax: 300Vdc / Imax:5A / Pmax:150W | |||
Binary Output (Semiconductor Type) | ||||
Quantity | 4pairs | |||
Type: | Open-collector, 14 pin Aviation socket | |||
Break Capacity DC |
5~15Vdc / 5mA, 10mA max
AC not permit
|
|||
Response time: | 100us | |||
Synchronization | ||||
Synchronization Mode |
GPS, SMA type antenna connector
IRIG-B, FT3
IEEE1588
|
|||
Power supply & Environment | ||||
Nominal Input Voltage | 100~240Vac | |||
Permissible Input Voltage | 85~264Vac, 125~350VDC | |||
Nominal Frequency | 50/60Hz | |||
Permissible Frequency | 45Hz~65Hz | |||
Power Consumption | 1500 VA max | |||
Connection Type | Standard AC socket 60320 | |||
Operating Temperature | -10℃~55℃ | |||
Storage Temperature | -20℃~70℃ | |||
Humidity | <95%RH, non-condensing | |||
Others | ||||
PC Connection | RJ45 Ethernet, 10/100/1000M | |||
Grounding Terminal | 4mm banana socket | |||
Weight | 18 Kg | |||
Dimensions(W x D x H) | 468×375×164(mm) |
Additional Information (Optional Modules)
DC Measurement Input (Transducer calibrator) | |||
Voltage Input | Range | 0~±10V dc | |
Max Input | ±11V dc | ||
Accuracy | <0.02% rg Typ. <0.05% rg Guar. | ||
Input Impedance | 1Mohm | ||
Current Input | Range | 0~±1mA / 1~±20mA, auto range | |
Max Input | 600mA | ||
Accuracy | <0.02% rg Typ. <0.05% rg Guar. | ||
Input Impedance | 15 ohm | ||
AC/DC Measurement Input (Standard meter) | |||
Input Quantity | 8 channels (blend with binary input pairs) | ||
Voltage range | 0~600Vrms (Rg:0.1V,1V, 10V, 60V, 600V) | ||
Voltage accuracy | <0.1% Rg | ||
Current range | 0~5Arms(clamp input) | ||
Current accuracy | <0.1% Rg | ||
Sample rate | 10KHz | ||
Input impedance | 600KΩ | ||
Frequency range | 45~65Hz, Accuracy < 0.01Hz | ||
Phase accuracy | 0~360°, <0.2° Typ. | ||
Transient Recorder | |||
Input Quantity | 8 input channels (blend with binary input pairs) | ||
Recorder time | Max 50 Sec. | ||
Energy Meter Calibration | |||
Sensor Usage | Mechanical meters / Electronic meters | ||
Sensor Output | High lever:>4.5V, Low level:<0.2V | ||
Pulse Input | 1 pulse input port | ||
Pulse Range | 500KHz pulse input Max. | ||
Pulse Output | 1 Transistor output, Open-collector, 5-15Vdc/5mA |
Company Details
Business Type:
Manufacturer,Seller
Year Established:
1999
Total Annual:
5 MIllion-9 MIllion
Employee Number:
150~200
Ecer Certification:
Verified Supplier
Who am I ? Since its establishment in 1999, Kingsine Electric Automation Co., Ltd. has focused on researching and developing, producing, and selling Protection Relay Test Sets, CT Analyzers, Reference Power Sources and Calibrators, Voltage and Current Amplifiers, Electricity Monitoring Systems, a... Who am I ? Since its establishment in 1999, Kingsine Electric Automation Co., Ltd. has focused on researching and developing, producing, and selling Protection Relay Test Sets, CT Analyzers, Reference Power Sources and Calibrators, Voltage and Current Amplifiers, Electricity Monitoring Systems, a...
Get in touch with us
Leave a Message, we will call you back quickly!