Place Of Origin | Guangzhou ,China |
Power supply | 220V,50HZ |
Drain pipe | 3/4" |
Motor | Single Phase Capactive Motor |
Pipe connection | 3/4" |
Coil | High-purity Copper Tubes And Aluminum Cooling Fins |
Fan | Double Inlet Centrifugal Fan |
Fluid | Chilled Water/hot Water |
coil rows | 4 Rows----3 Rows |
Brand Name | JETEX |
Model Number | FP-300KM---FP1400KM |
Certification | ISO 9001:2015 Certification |
Place of Origin | Panyu ,Guangzhou.China |
View Detail Information
Explore similar products
Chilled Water Cassette Fan Coil Unit Ceiling Mounted Air Conditioning Ventilatio
Jetex Horizontal Fan Coil Unit 2040 m³/h 11kw Cooling
Customizable Concealed Horizontal Type Ducted Fan Coil Unit Air Conditioner
Jetex Chilled Water Commercial Fan Coil Units Horizontal Type With Return Box
Product Specification
Place Of Origin | Guangzhou ,China | Power supply | 220V,50HZ |
Drain pipe | 3/4" | Motor | Single Phase Capactive Motor |
Pipe connection | 3/4" | Coil | High-purity Copper Tubes And Aluminum Cooling Fins |
Fan | Double Inlet Centrifugal Fan | Fluid | Chilled Water/hot Water |
coil rows | 4 Rows----3 Rows | Brand Name | JETEX |
Model Number | FP-300KM---FP1400KM | Certification | ISO 9001:2015 Certification |
Place of Origin | Panyu ,Guangzhou.China | ||
High Light | Commercial Cassette Type Fcu Air Conditioner ,Chilled Water Fan Coil Unit ,Ceiling Cassette Fcu Air Conditioner |
A fan coil unit is an essential component of a coil cooling air conditioner system, designed to provide efficient heating and cooling for various spaces. Cassette FCU is a kind of commercial air conditioner, which is mostly used in offices and shopping malls.
1. The appearance of the unit is luxurious, the installation does not occupy effective indoor space, and it is harmoniously matched with the environment;
2. The unit sends air from all sides to increase comfort;
3. The use of a three-dimensional spiral wind cabinet makes the equipment operation noise lower.
Model ltem |
FP-200 (FP-34) |
FP-300 (FP-51) |
FP-400 (FP-68) |
FP-500 (FP-85) |
FP-600 (FP-102) |
FP-800 (FP-136) |
FP-1000 (FP-170) |
FP-1200 (FP-204) |
FP-1400 (FP-238) |
|||||
Standard Air Volume(m³h) |
H | 340 | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 | 2380 | ||||
M | 255 | 382 | 510 | 638 | 765 | 1020 | 1275 | 1530 | 1785 | |||||
L | 170 | 255 | 340 | 425 | 510 | 680 | 850 | 1020 | 1190 | |||||
(W)Cooling Capacity | 1800 | 2700 | 3600 | 4500 | 5400 | 7200 | 9000 | 10800 | 12600 | |||||
(W)Heating Capacity | 2700 | 4050 | 5400 | 6750 | 8100 | 10800 | 13500 | 16200 | 18900 | |||||
PTC(optional) | power(KW) | 1.5 | 2.0 | 2.5 | 3.0 | 3.0 | 4.5 | 4.5 | 6.0 | 6.0 | ||||
Electric current (A) | 6.8 | 9.1 | 11.4 | 13.7 | 13.7 | 20.5 | 20.5 | 27.3 | 27.3 | |||||
Static Pressure(Pa) |
S | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 | ||||
E | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 50 | 50 | |||||
Noise Level(dB(A)) |
S | ≤37 | ≤39 | ≤41 | ≤43 | ≤45 | ≤46 | ≤48 | ≤50 | ≤52 | ||||
E | ≤40 | ≤42 | ≤44 | ≤46 | ≤47 | ≤48 | ≤50 | ≤54 | ≤56 | |||||
Coil |
Type | High-purity Copper Tubes And Aluminium Cooling Fins | ||||||||||||
Water Flow(1000kg/h) |
0.34 | 0.50 | 0.66 | 0.81 | 0.96 | 1.28 | 1.61 | 1.92 | 2.18 | |||||
Pressure Drop(KPa) |
30 | 30 | 30 | 30 | 40 | 40 | 40 | 40 | 50 | |||||
Max Working Press(MPa) | 1.6 | |||||||||||||
Motor |
Power Input | S | 37 | 52 | 62 | 76 | 96 | 134 | 152 | 189 | 228 | |||
E | 44 | 59 | 72 | 87 | 108 | 156 | 174 | 250 | 300 | |||||
Quantity | 1 | 2 | ||||||||||||
Fan |
Type | Double Inlet Centrifugal Fan | ||||||||||||
Quantity | 1 | 2 | 3 | 4 |
Notes:
1.Refrigeration conditions: DB=27℃, WB=19.5℃, TW₁=7℃, △TW=5℃; Heating conditions: DB=21℃, TW₁=60℃, △TW=10℃.
2.Cooling and heating capacities are values at high speed. At medium air volume, they are approximately 84% of the values in the table; at low air volume, approximately 74%.
3.The coil is a 3-row tube with a fin density of 12 fins per inch. For other types such as 2-row tubes, please specify separately.
4.The noise values must be tested under conditions conforming to the relevant requirements in the national standard GB-T19232-2003.
5.The motor nameplate power of this product is the output power, while the power shown in the table above is the motor input power. Please note!
6.In the model numbers above, the digits in parentheses represent the high-speed air volume: quantity ×10 m³/h. Example: FP-34 has an air volume of 340 m³/h.
Cassette Type(KM)Unit
Model ltem |
FP-300KM | FP-400KM | FP-500KM | FP-600KM | FP-800KM | FP-1000KM | FP-1200KM | FP-1400KM | |||
Standard Air Volume(m³h) |
HIGH | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 | 2380 | ||
MEDIUM | 383 | 510 | 638 | 765 | 1020 | 1275 | 1530 | 1785 | |||
LOW | 255 | 340 | 425 | 510 | 680 | 850 | 1020 | 1190 | |||
Cooling Capacity(W) |
HIGH | 2700 | 3600 | 4500 | 5400 | 7200 | 9000 | 10800 | 12600 | ||
Heating Capacity(W) |
HIGH | 4050 | 5400 | 6750 | 8100 | 10800 | 13500 | 16200 | 18900 | ||
Dimension |
A | 670 | 710 | 960 | 960 | 1060 | 1060 | 1060 | 1060 | ||
K | 470 | 610 | 860 | 860 | 960 | 960 | 960 | 960 | |||
JETEX offers a range of high-quality Fan Coil Units suitable for various application occasions and scenarios.
The Fan Coil Units are equipped with high-purity Copper Tubes and Aluminum Cooling Fins in the coil, ensuring effective heat transfer and optimal cooling efficiency. The Single Phase Capacitive Motor enhances the overall performance of the unit, providing consistent airflow for a comfortable environment.
Q: What is the brand name of the Fan coil unit?
A: The brand name of the Fan coil unit is JETEX.
Q: Where is the Fan coil unit manufactured?
A: The Fan coil unit is manufactured in Guangzhou, China.
Q: What are the available model numbers for the Fan coil unit?
A: The available model numbers for the Fan coil unit range from FP-300KM---FP1400KM.
Q: Is the Fan coil unit suitable for residential use?
A: Yes, the Fan coil unit is suitable for both residential and commercial use.
Q: Does the Fan coil unit come with a warranty?
A: For information regarding warranty, please refer to the product documentation or contact customer support.
Company Details
Business Type:
Manufacturer
Year Established:
1995
Total Annual:
8000000-13000000
Employee Number:
50~120
Ecer Certification:
Verified Supplier
Founded in 1995,Guangzhou Jetex-Lloyd's Machinery Ltd is an energy-saving and environmentally friendly technology enterprise specializing in the R&D, manufacturing, sales, and service of HVAC, air handling units, and related products. The company upholds the management concept... Founded in 1995,Guangzhou Jetex-Lloyd's Machinery Ltd is an energy-saving and environmentally friendly technology enterprise specializing in the R&D, manufacturing, sales, and service of HVAC, air handling units, and related products. The company upholds the management concept...
Get in touch with us
Leave a Message, we will call you back quickly!