Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"3.3kV 4.5kV 6.5kV High Power IGBT Module XB Series Mitsubishi IGBT Module","imgUrl":"https:\/\/img.ismap.com\/nimg\/0f\/69\/72cc82e165693e2d636b425b7f5a-200x200-1\/3_3kv_4_5kv_6_5kv_high_power_igbt_module_xb_series_mitsubishi_igbt_module.jpg","attrs":{"Brand Name":"","Model Number":"XB","Certification":"CE\u3001RoHS\u3001UL\u3001TUV\u3001EN 50121\u3001IEC 60747","Place of Origin":"Japan"}}
{"title":"DY Series Mitsubishi IGBT Module 1200V Industrial Inverter IGBT Module","imgUrl":"https:\/\/img.ismap.com\/nimg\/1c\/32\/ee95f5b1335ba93d950f176d5fd1-200x200-1\/dy_series_mitsubishi_igbt_module_1200v_industrial_inverter_igbt_module.jpg","attrs":{"Brand Name":"","Model Number":"DY","Certification":"CE\u3001UL\u3001RoHS\u3001REACH\u3001VDE\u3001ISO9001","Place of Origin":"Japan"}}
{"title":"Frequency Inverter VFD IGBT 7th Gen NX Mitsubishi IGBT Ultra Low Loss 175\u2103 Tj","imgUrl":"https:\/\/img.ismap.com\/nimg\/e0\/0f\/3c7a297e34711ffd9d233060cfbd-200x200-1\/frequency_inverter_vfd_igbt_7th_gen_nx_mitsubishi_igbt_ultra_low_loss_175_e2_84_83_tj.jpg","attrs":{"Brand Name":"","Model Number":"NX","Certification":"ROHS\u3001UL","Place of Origin":"Japan"}}
{"title":"LV100 Mitsubishi IGBT Module 1200V-2000V 800A-1800A IPM Power Module","imgUrl":"https:\/\/img.ismap.com\/nimg\/3b\/47\/f97f4063d7e2a9a69d9eff2dc4a3-200x200-1\/lv100_mitsubishi_igbt_module_1200v_2000v_800a_1800a_ipm_power_module.jpg","attrs":{"Brand Name":"","Model Number":"LV100","Certification":"CE \u3001RoHS \u3001UL1557","Place of Origin":"Japan"}}
{"title":"Mitsubishi MPD 6th Gen IGBT Module Low Loss 175\u2103 Tj For Solar Wind Power","imgUrl":"https:\/\/img.ismap.com\/nimg\/c9\/cf\/2bd8db1f1274c535294dde3fc90a-200x200-1\/mitsubishi_mpd_6th_gen_igbt_module_low_loss_175_e2_84_83_tj_for_solar_wind_power_converters.jpg","attrs":{"Brand Name":"","Model Number":"MPD","Certification":"CE\u3001UKCA\u3001RoHS\u3001UL\/culus\u3001KC\u3001IEC 61508\u3001IEC 62061","Place of Origin":"Japan"}}
{"title":"Mitsubishi S1 1.7kV HVIGBT Module Low Loss IPM Power Module For Rail","imgUrl":"https:\/\/img.ismap.com\/nimg\/6c\/97\/7cc2947befee32bd782b8d62cec5-200x200-1\/mitsubishi_s1_1_7kv_hvigbt_module_low_loss_ipm_power_module_for_rail.jpg","attrs":{"Brand Name":"","Model Number":"S1","Certification":"CE\u3001T\u00dcV\u3001UL 1557\u3001IEC 60747\u3001RoHS\u3001EN 50121\u3001UL 508C\u3001ISO 9001","Place of Origin":"Japan"}}
{"title":"Infineon TRENCHSTOP IGBT T5\/T6\/EDT3 High Efficiency PV Inverter IGBT Module","imgUrl":"https:\/\/img.ismap.com\/nimg\/26\/a9\/ae9bf82703d322be129577f433de-200x200-1\/infineon_trenchstop_igbt_t5_2ft6_2fedt3_high_efficiency_pv_inverter_igbt_module.jpg","attrs":{"Brand Name":"","Certification":"CE \u3001UL 1557 \u3001RoHS \u3001JEDEC","Place of Origin":"Japan","Minimum Order Quantity":"1"}}
International Express(DHL/FEDEX/TNT/UPS/ARAMEX)/Sea Freight / Air Freight / International Special Line
Freight Charge
For Industrial Equipment (E.G., PLC Modules, Inverters..), Shipping Cost Varies By Package Weight/Volume And Delivery Location. Contact Our Sales Team For A Customized Shipping Solution And Quote
International Express(DHL/FEDEX/TNT/UPS/ARAMEX)/Sea Freight / Air Freight / International Special Line
Freight Charge
For Industrial Equipment (E.G., PLC Modules, Inverters..), Shipping Cost Varies By Package Weight/Volume And Delivery Location. Contact Our Sales Team For A Customized Shipping Solution And Quote
XB Series High Power IGBT Module 3.3kV/4.5kV/6.5kV Reliable -40℃~150℃ Compact Single-Tube Package for Rail Transit Industrial Inverter PV
XB Series IGBT Modules
High-power, high-voltage industrial core devices with exceptional reliability, operating at extreme temperatures from -40℃ to 150℃. Designed for rail transit, industrial inverters, and photovoltaic applications.
Core Technical Advantages
Proprietary RFC diode and CSTBT structure reduce switching loss and enhance stability during high-power operation
Optimized chip terminal structure and thickened insulation design provide 20x higher moisture resistance than conventional modules
Compact single-tube package design compatible with previous R series for direct replacement and upgrade
Key Performance Highlights
Reliability: Power cycle life > 10⁵ times, significantly extending service life and reducing maintenance frequency
Temperature Range: Stable operation from -40℃ to 150℃ in extreme industrial environments
Voltage & Current: Covers 3.3kV/4.5kV/6.5kV voltage levels and 750A~1500A rated current with low on-state voltage drop
Insulation Performance: 6.0kVrms (HC package) and 10.2kVrms (HG package) insulation grades for different industrial scenarios
High power density (5MW), low switching loss, high efficiency
High-voltage Photovoltaic Inverter
CM1200HC-90XB
4.5kV
1200A
Excellent moisture resistance and high efficiency for 1500V systems
Common Questions for Overseas Use
How to choose between 3.3kV and 4.5kV models?
Select based on equipment voltage requirements: 3.3kV for medium-voltage industrial frequency converters and rail auxiliary power supplies; 4.5kV for high-voltage motor drives and HVDC transmission.
HC or HG package for outdoor vs indoor use?
HC standard insulation for indoor dry environments; HG high insulation for outdoor and high-humidity environments to prevent moisture damage.
What about heat dissipation requirements?
All models require forced water cooling. Ensure proper thermal contact with water-cooled plates and maintain thermal resistance around 0.04K/W.