China Class 100 Cleanliness Level Highly Laminar Clean Bench for Particle Removal
China Class 100 Cleanliness Level Highly Laminar Clean Bench for Particle Removal

  1. China Class 100 Cleanliness Level Highly Laminar Clean Bench for Particle Removal

Class 100 Cleanliness Level Highly Laminar Clean Bench for Particle Removal

  1. MOQ: 1
  2. Price: Negotiate
  3. Get Latest Price
Payment Terms tt lc PayPal credit card
Delivery Time 18 days
Packaging Details plywood/wooden package
Material Acrylic plate/Aluminum
Air Volume 1000-1200m³/h
Type HEPA
Filter Efficiency 99.99% 0.3um
Voltage 110V/220V 50HZ/60HZ
Air Flow Vertical/Horizontal
Brand Name ZJNF
Model Number ZJNF-1
Certification CE
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms tt lc PayPal credit card Delivery Time 18 days
Packaging Details plywood/wooden package Material Acrylic plate/Aluminum
Air Volume 1000-1200m³/h Type HEPA
Filter Efficiency 99.99% 0.3um Voltage 110V/220V 50HZ/60HZ
Air Flow Vertical/Horizontal Brand Name ZJNF
Model Number ZJNF-1 Certification CE
Place of Origin China
High Light Class 100 laminar clean benchhighly laminar clean benchclean bench for particle removal

Clean Bench (Laminar Flow Cabinet)

A clean bench is an air purification device that provides a locally high-cleanliness environment. It generates a unidirectional stream of purified air through a filtration system, widely used for aseptic operations. Key aspects include its core functions, working principles, and operational protocols:


I. Working Principle

  1. Air Purification Process
    Room air is initially filtered by a pre-filter, then pressurized by a fan into a plenum chamber. It undergoes secondary filtration through a High-Efficiency Particulate Air (HEPA) or Ultra-Low Penetration Air (ULPA) filter, forming a vertical or horizontal laminar airflow (typical velocity: 0.3–0.6 m/s). This effectively removes contaminants from the work zone, achieving Class 100 cleanliness (per U.S. Federal Standard 209E)
  2. Airflow Direction Classification
    • Vertical Laminar Flow‌: Airflows downward, suitable for biomedical applications to minimize operator exposure
    • Horizontal Laminar Flow‌: Airflows horizontally outward, commonly used in electronics industries where health risks are lower

II. Core Structure & Types

Classification Basis Type Features & Applications
Airflow Direction Vertical Laminar Flow Higher noise (top-mounted fan), ideal for pharmaceuticals
  Horizontal Laminar Flow Lower noise, suited for electronics
Operation Configuration Single operator, front-access e.g., VD-650 model (650×550×850 mm)
  Dual-operator (front/dual-side) Enhanced collaboration efficiency
Application Focus Standard Type General aseptic operations
  Biological/Medical Type Equipped with UV lamp for microbiological work

III. Key Application Fields

  • Biomedicine‌: Cell culture, microbial inoculation, sterile formulation filling
  • Electronics Manufacturing‌: Semiconductor packaging, precision component assembly (dust control)
  • Food & Cosmetics‌: Microbial testing, high-cleanliness product filling
  • Research & Agriculture‌: Plant tissue culture, animal pathogen detection

IV. Operating Procedures & Precautions

  1. Startup Protocol‌:
    • Wipe surfaces with ethanol and sterilize via UV irradiation for 30 min
    • Turn on fan and lighting; keep glass sash closed
  2. Safety Notes‌:
    • Does not protect operators‌: Operates under positive pressure, safeguarding samples but not isolating users from hazards (e.g., chemical vapors, pathogens)
    • Distinguish from Biosafety Cabinets‌: Biosafety cabinets use negative pressure to protect personnel and environment
  3. Maintenance Requirements‌:
    • Replace pre-filters and HEPA/ULPA filters regularly; install in double-door rooms in tropical climates for extended lifespan
    • Avoid blocking air inlets to ensure stable airflow

V. Technical Parameters Example (VD-650 Model)

Parameter Value
Cleanliness Class ISO Class 5 (Class 100) @ ≥0.5μm
Microbial Control ≤0.5 CFU/plate·hour
Noise Level ≤58 dB(A)
Power Supply AC220V/50Hz, ≤0.3 kW

 

 

Product Details

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2003

  • Total Annual:

    3000000-4000000

  • Employee Number:

    200~300

  • Ecer Certification:

    Verified Supplier

Shenzhen ZhongJian South Environment Co., Ltd was founded in 2003. Which is the only high-tech technology company in Southern China with CNAS certification   We are mainly engaged in Designing Manufacturing, Testing & Verification, Manufacturing Processes and Quality Control, ... Shenzhen ZhongJian South Environment Co., Ltd was founded in 2003. Which is the only high-tech technology company in Southern China with CNAS certification   We are mainly engaged in Designing Manufacturing, Testing & Verification, Manufacturing Processes and Quality Control, ...

+ Read More

Get in touch with us

  • Reach Us
  • Shenzhen Zhong Jian South Environment Co., Ltd.
  • 9th Floor, Block C, Coolpad Building, Intersection Of Keyuan Avenue And Baoshen Road, Nanshan Gaoxin North District, Songpingshan Community, Xili Street, Shenzhen city, Guangdong, China
  • https://www.iairpurifier.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement