{"title":"Low Voltage Power Distribution Compact Sandwich Busbar Electrical Busduct","imgUrl":"https:\/\/img.ismap.com\/nimg\/56\/97\/f5944ba7bda49680a98266c02e2b-200x200-1\/low_voltage_power_distribution_compact_sandwich_busbar_electrical_busduct.jpg","attrs":{"Brand Name":"Bosun","Certification":"ISO9001, CE, CQC,CCC","Place of Origin":"Chongqing","Minimum Order Quantity":"1"}}
{"title":"IP54 IP65 IP66 Copper Aluminum Medium Voltage Bus Duct 415V 690V","imgUrl":"https:\/\/img.ismap.com\/nimg\/54\/cc\/401cd22b13f6d734b5b234123102-200x200-1\/ip54_ip65_ip66_copper_aluminum_medium_voltage_bus_duct_415v_690v.jpg","attrs":{"Brand Name":"Bosun","Certification":"ISO9001, CE, CQC,CCC","Place of Origin":"Chongqing","Minimum Order Quantity":"1"}}
{"title":"3000 AMP 1600 AMP Feeder Bus Duct for Electrical Grid Systems","imgUrl":"https:\/\/img.ismap.com\/nimg\/8d\/c3\/f781e35da5ae741923c45e2ebe52-200x200-1\/3000_amp_1600_amp_feeder_bus_duct_for_electrical_grid_systems.jpg","attrs":{"Brand Name":"Bosun","Certification":"ISO9001, CE, CQC,CCC","Place of Origin":"Chongqing","Minimum Order Quantity":"1"}}
{"title":"15KV Mylar or Epoxy Insulated Electrical Rising Mains Bus Duct 415V 480V 690V","imgUrl":"https:\/\/img.ismap.com\/nimg\/4b\/f7\/3bbb702aaa0655e25123adf71711-200x200-1\/15kv_mylar_or_epoxy_insulated_electrical_rising_mains_bus_duct_415v_480v_690v.jpg","attrs":{"Brand Name":"Bosun","Certification":"ISO9001, CE, CQC,CCC","Place of Origin":"Chongqing","Minimum Order Quantity":"1"}}
{"title":"3000AMP 4000AMP High Voltage Medium Voltage Low Voltage Bus Duct for Dock","imgUrl":"https:\/\/img.ismap.com\/nimg\/6c\/8c\/cd2ea8f51b68acf540aaf56a1c89-200x200-1\/3000amp_4000amp_high_voltage_medium_voltage_low_voltage_bus_duct_for_dock.jpg","attrs":{"Brand Name":"Bosun","Certification":"ISO9001, CE, CQC,CCC","Place of Origin":"Chongqing","Minimum Order Quantity":"1"}}
{"title":"ODM Busway Bus Duct Electrical for Power Generation Plants and Renewable Energy","imgUrl":"https:\/\/img.ismap.com\/nimg\/4e\/2d\/330da2507c2027eb85214f0dd5de-200x200-1\/odm_busway_bus_duct_electrical_for_power_generation_plants_and_renewable_energy_systems.jpg","attrs":{"Brand Name":"Bosun","Certification":"ISO9001, CE, CQC,CCC","Place of Origin":"Chongqing","Minimum Order Quantity":"1"}}
{"title":"Low Voltage High Voltage Mylar or Epoxy Insulated Feeder Electrical Busduct for","imgUrl":"https:\/\/img.ismap.com\/nimg\/98\/17\/05664a2c8064512f9a37ef69171f-200x200-1\/low_voltage_high_voltage_mylar_or_epoxy_insulated_feeder_electrical_busduct_for_substation.jpg","attrs":{"Brand Name":"Bosun","Certification":"ISO9001, CE, CQC,CCC","Place of Origin":"Chongqing","Minimum Order Quantity":"1"}}
Low Voltage Power Distribution Compact Sandwich 4000 AMP 1600 AMP Bus Duct
Product Description
Busducts are often used in applications where space is limited or where a high degree of flexibility is required. For example, busducts can be used in buildings with limited ceiling space, or in facilities where equipment may need to be moved or reconfigured over time.
Busducts can be designed to incorporate a variety of protective devices, such as fuses, circuit breakers, and current-limiting devices. These devices help to protect the busduct and connected equipment from overloads, short circuits, and other types of faults.
One advantage of busducts over traditional cable-based systems is that they offer better electromagnetic compatibility (EMC). This is because the metal enclosure surrounding the busbars provides shielding against external electromagnetic fields.
Busducts can be designed to meet specific requirements for thermal performance. For example, busducts used in high-current applications may incorporate cooling systems to help dissipate heat and prevent overheating.
Busducts can be more expensive to install than traditional cable-based systems, particularly for smaller power ratings. However, for larger power ratings, busducts can offer significant cost savings over traditional systems due to their higher efficiency and lower maintenance requirements.
Busducts can be designed to provide a high degree of fault tolerance and reliability. For example, busducts can be designed with redundant pathways and components to ensure that power can still be delivered in the event of a fault or failure.
Busducts can be designed to meet a variety of international standards, such as those set by the IEC or NEMA. These standards specify requirements for things like insulation, current-carrying capacity, and fault tolerance, and can help ensure that busducts are safe and reliable.
In summary, busducts are a flexible and efficient way to distribute large amounts of power over short distances. They offer several advantages over traditional cable-based systems, including better EMC, higher reliability, and greater fault tolerance. They can also be designed to meet specific requirements for thermal performance, safety, and international standards.
Specification
Conductor Material
Copper or Aluminum Bar
Rated Working Voltage
415V or 690V
Rated Frequency
50/60Hz
Protection Class
IP54/IP65/IP66
Rated Operating Current
250~6300A
Configuration
3P3W, 3P4W, 3P5W
Surface treatment
Powder Coating Spray
Insulation
Mylar or Epoxy
Material
1.The cabinet door adopts a double beveled edge process, which increases the structural strength of the same material by 50%.
2.The installation holes are all made using a multi-layer stamping and stretching process, which reduces the sliding wire situation by more than 80%.
3.The inlet and outlet holes adopt a composite structure of knockdown holes and square holes, which can be flexibly selected during on-site installation.
4.The box adopts a double folding process, which increases the structural strength of the same material by 50%
.
Payment and Delivery
Engineering
1.Power generation plants
2.Substations
3.Commercial buildings
4.Data centers
5.Renewable energy systems
6.Transportation
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer
Year Established:
1996
Total Annual:
200000-300000
Employee Number:
160~200
Ecer Certification:
Active Member
Chongqing Bosun Electrical Co., Ltd. was established in 1996, located in Banan District Chongqing China, with convenient transportation, covers an area of 8,000 square meters.
Devoted in the research and development, manufacturing, installation, and sales of complete sets of high ...
Chongqing Bosun Electrical Co., Ltd. was established in 1996, located in Banan District Chongqing China, with convenient transportation, covers an area of 8,000 square meters.
Devoted in the research and development, manufacturing, installation, and sales of complete sets of high ...