China KGD WQ 513 Gasoline Vehicle Emission Gas Analyzer With 30min Pre-heating Time
China KGD WQ 513 Gasoline Vehicle Emission Gas Analyzer With 30min Pre-heating Time

  1. China KGD WQ 513 Gasoline Vehicle Emission Gas Analyzer With 30min Pre-heating Time

KGD WQ 513 Gasoline Vehicle Emission Gas Analyzer With 30min Pre-heating Time

  1. MOQ: 1PCS
  2. Price:
  3. Get Latest Price
Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Resolution NO/NO₂: 1ppm; CO₂: 0.01%;
Response Time HC/CO/CO₂: T90 ≤ 8s; NO/NO₂: T90 ≤ 10s; O₂: T90 ≤ 12s
Pre - heating Time 30min
Communication RS - 485/232
Power Supply 100 - 240VAC, 150W
Model Number KGD-WQ-513
Certification CE
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Resolution NO/NO₂: 1ppm; CO₂: 0.01%; Response Time HC/CO/CO₂: T90 ≤ 8s; NO/NO₂: T90 ≤ 10s; O₂: T90 ≤ 12s
Pre - heating Time 30min Communication RS - 485/232
Power Supply 100 - 240VAC, 150W Model Number KGD-WQ-513
Certification CE Place of Origin CHINA
High Light Gasoline Vehicle Emission Gas Analyzer150W Power Supply Gas Analyzer30min Pre-heating Time Gas Analyzer

KGD - WQ - 513 Vehicle Emission Gas Analyzer (Gasoline Vehicle)

Product Introduction

The KGD - WQ - 513 Vehicle Emission Gas Analyzer (Gasoline Vehicle) detects the concentration of NO based on high - precision micro - flow infrared dual - gas - chamber sensor technology with independent intellectual property rights and an international PCT patent (PCT/CN2018100767). The sensor adopts a dual - gas - chamber structure and special filters, which solves problems such as environmental temperature instability and aging of electronic components. It measures the concentration of NO₂ based on the non - dispersive ultraviolet (NDUV) absorption method without the need for a NOₓ converter. It simultaneously detects the concentrations of HC, CO, and CO₂ in vehicle exhaust based on the principle of non - dispersive infrared (NDIR) absorption technology, and measures the concentration of O₂ using long - life electrochemistry (ECD) analysis technology, and automatically calculates and displays the air - fuel ratio.

Product Features

  • Directly measures NO and NO₂ without the need for a NOₓ converter. It has a compact structure and requires no maintenance in the later stage.
  • High measurement accuracy, good stability, strong anti - interference ability, and is not affected by moisture.
  • Multi - stage filtration, which makes the system more durable.
  • Core software algorithm that can perform linear correction processing on gas concentration signals.
  • Automatic temperature and pressure compensation, and reserves interfaces for oil temperature and rotational speed.

Technical Parameters

Gas Type Measuring Range Absolute Error Relative Error
HC (0 - 2000)×10⁻⁶VOL, (2001 - 5000)×10⁻⁶VOL, (5001 - 9999)×10⁻⁶VOL ± 4×10⁻⁶VOL ± 3%, ± 5%, ± 10%
CO (0.00 - 10.00)×10⁻²VOL, (10.01 - 14.00)×10⁻²VOL ± 0.02×10⁻²VOL ± 3%, ± 5%
CO₂ (0 - 16.0)×10⁻²VOL, (16.01 - 18.0)×10⁻²VOL ± 0.3×10⁻²VOL ± 3%, ± 5%
NO (0 - 4000)×10⁻⁶VOL, (4001 - 5000)×10⁻⁶VOL ± 25×10⁻⁶VOL ± 4%, ± 8%
NO₂ (0 - 1000)×10⁻⁶VOL ± 25×10⁻⁶VOL ± 4%
O₂ (0.0 - 25.0)×10⁻²VOL ± 0.1×10⁻²VOL -
Note The absolute error and relative error listed in the table, meeting one of the requirements is sufficient.
Resolution NO/NO₂: 1ppm; CO₂: 0.01%;
Response Time HC/CO/CO₂: T90 ≤ 8s; NO/NO₂: T90 ≤ 10s; O₂: T90 ≤ 12s
Pre - heating Time 30min
Communication RS - 485/232
Power Supply 100 - 240VAC, 150W

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement