China 2-50 KPa Inlet Gas Pressure KGD MQ 527 Online Biogas Monitoring System With
China 2-50 KPa Inlet Gas Pressure KGD MQ 527 Online Biogas Monitoring System With

  1. China 2-50 KPa Inlet Gas Pressure KGD MQ 527 Online Biogas Monitoring System With

2-50 KPa Inlet Gas Pressure KGD MQ 527 Online Biogas Monitoring System With

  1. MOQ: 1PCS
  2. Price:
  3. Get Latest Price
Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Response Time T90<60s
Optimal Flow Rate (0.7 - 1.2) L/min
Inlet Gas Pressure (2 - 50) kPa
Power Supply 100 - 240VAC, 100W
Analog Signal 4 - 20mA
Digital Signal RS232/485; Ethernet
Brand Name KACISE
Model Number KGD-MQ-527
Certification CE
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Response Time T90<60s Optimal Flow Rate (0.7 - 1.2) L/min
Inlet Gas Pressure (2 - 50) kPa Power Supply 100 - 240VAC, 100W
Analog Signal 4 - 20mA Digital Signal RS232/485; Ethernet
Brand Name KACISE Model Number KGD-MQ-527
Certification CE Place of Origin CHINA
High Light 2-50 kPa Biogas Monitoring SystemOnline Biogas Monitoring SystemRS232/485 Biogas Monitoring System

KGD - MQ - 527 Online Biogas Monitoring System

Product Introduction

The KGD - MQ - 527 Online Biogas Monitoring System is a new - generation biogas monitoring system. It accurately measures the concentration of H2S before and after biogas desulfurization based on Ultraviolet Differential Optical Absorption Spectroscopy (UV - DOAS) gas analysis technology, measures the concentrations of CH4 and CO2 using Non - Dispersive Infrared (NDIR) gas analysis technology, and measures the concentration of O2 by Electrochemical Detection (ECD) method. With a modular sensor design, it can realize continuous online monitoring of biogas components.

To ensure the efficiency of biogas desulfurization equipment, two sampling channels are used before and after the scrubber to monitor the H2S concentration in real - time, effectively preventing excessive H2S from damaging the downstream pipelines and other equipment. The KGD - MQ - 527 is suitable for various biogas working conditions on - site, providing an ideal solution for minimizing user investment and optimizing the biogas digester monitoring process.

Product Features

  • Unique combination technology of UV - DOAS, NDIR, and ECD.
  • Capable of measuring high and low range H2S before and after desulfurization.
  • High - precision, long - life UV - DOAS H2S sensor.
  • Continuously monitors CH4, CO2, H2S, and O2 to optimize process control.
  • Modular sensor design for easy calibration and maintenance.
  • Flexible gas regulation configuration, with ranges customizable according to on - site requirements.
  • Stainless - steel protection cabinet to prevent the instrument from gas corrosion during long - term operation.
  • Explosion - proof design, suitable for flammable and explosive hazardous areas.

Technical Parameters

Measured Components Measurement Principle Measurement Range Resolution Measurement Accuracy Repeatability
H2S UV - DOAS 0 - 500~5000ppm 1ppm ±2%F.S. ≤1%F.S.
CH4 NDIR 0 - 100% 0.01% ±2%F.S. ≤1%F.S.
CO2 NDIR 0 - 100% 0.01% ±2%F.S. ≤1%F.S.
O2 ECD 0 - 25% 0.01% ±2%F.S. ≤1%F.S.
Response Time T90<60s
Optimal Flow Rate (0.7 - 1.2) L/min
Inlet Gas Pressure (2 - 50) kPa
Power Supply 100 - 240VAC, 100W
Pretreatment Unit (Optional)
Dewatering Pretreatment unit (optional)
Filter Gravity water - separator with manual drain valve (standard)
Gas/water separator with automatic drain valve (standard)
Sampling Channel 1 - 4 sampling channels can be customized (optional)
Trace heating cable Trace heating cable for ambient temperature below 0°C (optional)
Sampling Pump Low - pressure sampling pump (optional)
Condenser Condenser for quickly removing gaseous water in high - humidity sample gas (optional)
Mechanical Parameters
Housing Stainless steel floor - standing cabinet
Dimensions (HWD) 1720*700*500(mm)
Explosion - proof Grade ExdIICT6 (analyzer)
Protection Level IP65
Communication  
Analog Signal 4 - 20mA
Digital Signal RS232/485; Ethernet
Alarm Condition High and low alarm relay output for each gas reading
Environmental Conditions
Operating Temperature (°C) -15°C - +45°C
Operating Humidity 0 - 95%RH (non - condensing)
Ambient Pressure 80 - 120kPa

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement