China factories

China factory - Xi'an Kacise Optronics Co.,Ltd.

Xi'an Kacise Optronics Co.,Ltd.

  • China ,Shaanxi
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China KGD-MQ-525Online Gas Analysis System
China KGD-MQ-525Online Gas Analysis System

  1. China KGD-MQ-525Online Gas Analysis System

KGD-MQ-525Online Gas Analysis System

  1. MOQ: 1PCS
  2. Price:
  3. Get Latest Price
Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Measured Components CO/CO2/CH4/H2/O2/C2H2/C2H4/CnHm*/Calorific Value
Measurement Principle CO/CO2/CH4/C2H2/C2H4/CnHm: NDIR; H2: TCD; O2: ECD
Measurement Range CO/CO2/CH4/H2: (0 - 100%)
Measurement Range (Optional) O2: (0 - 25%); C2H2/C2H4/CnHm: (0 - 10%)
Accuracy CO/CO2/CH4/C2H2/C2H4/CnHm: ±1%F.S.; H2/O2: ±2%F.S.
Explosion - proof Grade Ex d IIC T4 Gb
Brand Name KACISE
Model Number KGD-MQ-525
Certification CE
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Measured Components CO/CO2/CH4/H2/O2/C2H2/C2H4/CnHm*/Calorific Value Measurement Principle CO/CO2/CH4/C2H2/C2H4/CnHm: NDIR; H2: TCD; O2: ECD
Measurement Range CO/CO2/CH4/H2: (0 - 100%) Measurement Range (Optional) O2: (0 - 25%); C2H2/C2H4/CnHm: (0 - 10%)
Accuracy CO/CO2/CH4/C2H2/C2H4/CnHm: ±1%F.S.; H2/O2: ±2%F.S. Explosion - proof Grade Ex d IIC T4 Gb
Brand Name KACISE Model Number KGD-MQ-525
Certification CE Place of Origin CHINA
High Light KGD-MQ-525 Gas Analysis SystemKGD-MQ-525 Online Gas Analysis SystemOnline Gas Analysis System

KGD-MQ-525Online Gas Analysis System

Product Introduction

The KGD - MQ - 525 Online Gas Analysis System is designed for specific working conditions where the sample gas contains dust, moisture, and tar. It consists of three parts: the pretreatment unit, the control unit, and the gas analysis unit. Based on the non - dispersive infrared (NDIR) gas analysis technology with independent intellectual property rights, the system can continuously and simultaneously measure the volume concentrations and calorific values of gases such as CO, CO2, CH4, H2, O2, C2H2, C2H4, and CnHm in real - time. It is applied to the online gas monitoring of process points such as coke oven gas, high - coke gas, biomass gas, and gas holders, which helps improve gas utilization efficiency, save energy, reduce consumption, and ensure the safety of industrial sites.

Product Features

  • Pretreatment Unit: Long service life and stable performance. Straight - tube or steam sampling probes can be selected according to different tar contents to effectively remove tar from the sample gas. A single - stage refrigerator is configured to remove moisture from the sample gas, and multi - stage filtration ensures the long - term online operation of the instrument.
  • Control Unit: Fully automated detection with simple operation. It is controlled by a PLC program, which can automatically complete gas washing and sampling, and also has a fault self - inspection function.
  • Gas Analysis Unit: Simultaneously measures gas volume concentration and calorific value. The Gasboard - 3100 (online type) gas analyzer with independent intellectual property rights is used for online gas analysis and detection. It can simultaneously measure the volume concentrations of multi - component gases such as CO, CO2, CH4, H2, O2, C2H2, C2H4, and CnHm, automatically calculate and display the calorific values of gas and biomass gas, and can replace the combustion - method calorific value instrument.
  • High safety factor with an explosion - proof grade of Ex d IIC T4 Gb.
  • Low maintenance and operation costs. It can monitor and display the system operation status in real - time without the need for manual attendance, greatly reducing maintenance costs.
  • Intelligent data management. Data can be transmitted to the superior centralized control system through multiple interfaces, providing real - time basis for remote monitoring and on - site process adjustment.

Technical Parameters

Parameter Details
Measured Components CO/CO2/CH4/H2/O2/C2H2/C2H4/CnHm*/Calorific Value
Measurement Principle CO/CO2/CH4/C2H2/C2H4/CnHm: NDIR; H2: TCD; O2: ECD
Measurement Range CO/CO2/CH4/H2: (0 - 100%)
Measurement Range (Optional) O2: (0 - 25%); C2H2/C2H4/CnHm: (0 - 10%)
Accuracy CO/CO2/CH4/C2H2/C2H4/CnHm: ±1%F.S.; H2/O2: ±2%F.S.
Explosion - proof Grade Ex d IIC T4 Gb
Electrical Parameters Electrical parameters
Display LCD Display
Communication RS - 232/RS - 485, (4 - 20) mA, Ethernet
Functional Configuration Self - diagnosis function available, sensor status can be checked online
Functional Configuration Built - in zero - adjustment air pump for automatic air zero - adjustment

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement