China Portable Coal Gas Analyzer KGD - MQ - 513
China Portable Coal Gas Analyzer KGD - MQ - 513

  1. China Portable Coal Gas Analyzer KGD - MQ - 513

Portable Coal Gas Analyzer KGD - MQ - 513

  1. MOQ: 1PCS
  2. Price:
  3. Get Latest Price
Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Measured Components CO/CO₂/CH₄/H₂/O₂/C₂H₂/C₂H₄/CₙHₘ*/Calorific Value
Measurement Principle CO/CO₂/CH₄/C₂H₂/C₂H₄/CₙHₘ: NDIR; H₂: TCD; O₂: ECD
Linear Error CO/CO₂/CH₄/C₂H₂/C₂H₄/CₙHₘ: ±1%F.S.; O₂/H₂: ±2%F.S.
Resolution ≤ 0.01%
Repeatability ≤ 1%
Response Time T90 < 15s (NDIR)
Model Number KGD-MQ-513
Certification CE
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Measured Components CO/CO₂/CH₄/H₂/O₂/C₂H₂/C₂H₄/CₙHₘ*/Calorific Value Measurement Principle CO/CO₂/CH₄/C₂H₂/C₂H₄/CₙHₘ: NDIR; H₂: TCD; O₂: ECD
Linear Error CO/CO₂/CH₄/C₂H₂/C₂H₄/CₙHₘ: ±1%F.S.; O₂/H₂: ±2%F.S. Resolution ≤ 0.01%
Repeatability ≤ 1% Response Time T90 < 15s (NDIR)
Model Number KGD-MQ-513 Certification CE
Place of Origin CHINA
High Light Portable Coal Gas AnalyzerCoal Gas Analyzer KGD - MQ - 513

Portable Coal Gas Analyzer KGD - MQ - 513

Product Introduction

The Portable Coal Gas Analyzer KGD - MQ - 513 adopts non - dispersive infrared (NDIR) gas analysis technology with independent intellectual property rights, long - life electrochemical sensing technology, and MEMS - based thermal conductivity technology. It can simultaneously measure the calorific values of coal gas and biogas, as well as the volume concentrations of gases such as CO, CO₂, CH₄, H₂, O₂, and CₙHₘ.

Product Features

  • Simultaneously measures gas components and calorific values: It can simultaneously measure the volume concentrations of gases such as CO, CO₂, CH₄, H₂, O₂, and CₙHₘ, and automatically calculate and display the calorific values of coal gas and natural gas, replacing the combustion - type calorific value meter.
  • High measurement accuracy: No cross - interference among multi - component measured gases: CₙHₘ has no interference on the measurement result of CH₄, and CO, CO₂, and CH₄ have no interference on the measurement result of H₂. It is less affected by the outside world, and the change of gas sampling flow has no impact on the measurement result of the H₂ thermal conductivity sensor. Measuring the volume concentration of CₙHₘ ensures the accuracy of the calorific values of gases such as coke oven gas, mixed gas, producer gas, and straw gas.
  • Portable body design: Easy to carry, it can meet the needs of both on - site industrial measurement and laboratory airbag sampling analysis.
  • Intelligent power management: Soft - start power switch and intelligent battery power management avoid the instrument from operating under low - power conditions.
  • Simple data management: Automatically stores measurement data, with query and deletion functions, and can transmit data to the superior centralized control system through multiple interfaces.
  • Low cost of use: Compared with gas analysis technologies such as Orsat and chromatography, the measurement process does not require disassembly and installation, consumption of chemical reagents, etc. It has a simple structure, is easy to operate, and has no consumables.

Technical Parameters

Measured Components CO/CO₂/CH₄/H₂/O₂/C₂H₂/C₂H₄/CₙHₘ*/Calorific Value
Measurement Principle CO/CO₂/CH₄/C₂H₂/C₂H₄/CₙHₘ: NDIR; H₂: TCD; O₂: ECD
Measurement Range CO/CO₂/CH₄/H₂: (0 - 100)%
O₂: (0 - 25)%; C₂H₂/C₂H₄/CₙHₘ: (0 - 10)% (Optional)
Linear Error CO/CO₂/CH₄/C₂H₂/C₂H₄/CₙHₘ: ±1%F.S.; O₂/H₂: ±2%F.S.
Resolution ≤ 0.01%
Repeatability ≤ 1%
Response Time T90 < 15s (NDIR)
Optimal Flow Rate (0.7 - 1.2) L/min
Inlet Pressure (2 - 50) kPa
Gas Requirements Dust - free, water - free, oil - free
External Dimensions 412152294 (mm)
Weight 9kg
Electrical Parameters Electrical Parameters
Communication RS - 232
Power Supply Powered by built - in rechargeable lithium - ion battery, with an external 12.6V charger
Display LCD Display
Functional Configuration Built - in sampling air pump
Optional pretreatment device
Calorific value units Kcal/m³ and MJ/m³ can be freely switched
Self - diagnosis function available for on - line inspection of sensor status
Note CₙHₘ represents the sum of other hydrocarbons except methane.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement