China factories

China factory - Xi'an Kacise Optronics Co.,Ltd.

Xi'an Kacise Optronics Co.,Ltd.

  • China ,Shaanxi
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China KWS-850 On-line Multi Parameter Sensor For Dissolved Oxygen And COD Measurement
China KWS-850 On-line Multi Parameter Sensor For Dissolved Oxygen And COD Measurement

  1. China KWS-850 On-line Multi Parameter Sensor For Dissolved Oxygen And COD Measurement
  2. China KWS-850 On-line Multi Parameter Sensor For Dissolved Oxygen And COD Measurement
  3. China KWS-850 On-line Multi Parameter Sensor For Dissolved Oxygen And COD Measurement

KWS-850 On-line Multi Parameter Sensor For Dissolved Oxygen And COD Measurement

  1. MOQ: 1PCS
  2. Price:
  3. Get Latest Price
Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days
Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Output RS-485(Modbus/RTU)
Power consumption 5W@12V
power supply 12VDC±5%
Cable length 5 meters, other length can be customized
Accuracy ±0.4mg/L
Resolution 0.01mg/L
Brand Name KACISE
Model Number KWS-850
Certification CE
Place of Origin china

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C,D/A,D/P,T/T,Western Union,MoneyGram Supply Ability 1000 Piece/Pieces per Week negotiable
Delivery Time 5-8 work days Packaging Details each unit has individual box and all boxes are packed in standard packages or customers requests available
Output RS-485(Modbus/RTU) Power consumption 5W@12V
power supply 12VDC±5% Cable length 5 meters, other length can be customized
Accuracy ±0.4mg/L Resolution 0.01mg/L
Brand Name KACISE Model Number KWS-850
Certification CE Place of Origin china
High Light Dissolved Oxygen multi parameter sensorCOD measurement multi parameter sensorKWS-850 multi parameter sensor

KWS-850 on-line multi-parameter sensor for dissolved oxygen and COD measurement

Product Description

The KWS-850 on-line multi-parameter sensor is a technological marvel, purposefully engineered for the precise measurement of dissolved oxygen and COD (Chemical Oxygen Demand). This state-of-the-art device offers unrivalled accuracy and reliability in water quality monitoring.

For dissolved oxygen detection, it utilizes highly sensitive probes that can capture even the minutest fluctuations, which is crucial for maintaining the vitality of aquatic life. In terms of COD measurement, it employs advanced spectroscopic or electrochemical methods, ensuring accurate quantification of organic pollutants.

Its on-line capabilities enable seamless, real-time data transmission, empowering industries and environmental agencies to take prompt action. Whether it's safeguarding the water quality in a fish farm, or ensuring compliance at a sewage treatment plant, the KWS-850 is an indispensable asset. Compact and easy to install, it's designed to meet the demands of modern water management.

Feature

  • Digital sensor, RS-485 bus, Modbus/RTU communication protocol.
  • Optional digital sensors such as dissolved oxygen, COD, conductivity/salinity, turbidity, ammonia nitrogen, pH, ORP, etc., suitable for long-term online monitoring.
  • Integrated design, can measure 8 parameters (including temperature) at the same time.
  • Equipped with an automatic cleaning device, it can effectively clean the surface of the sensor, prevent microorganisms from attaching, measure more accurately, and lower maintenance costs.

Parameter

Dissolved Oxygen Probe
Measuring range 0~20mg/L
Accuracy ±0.4mg/L
Resolution 0.01mg/L
Turbidity Probe

Measuring range and

Accuracy

0~100NTU ±3%or±2NTU
0~1000NTU ±5%or±3NTU
Resolution 0.1NTU
Conductivity / Salinity Probe

Measuring range and

Resolution

0~5000uS/cm 1uS/cm
0~200mS/cm 0.1mS/cm
0~70PSU 0.1PSU
Accuracy ±1.5% F.S.
COD Probe
Measuring range COD Turbidity
0~200mg/L equiv. KHP 0~100NTU
0~500mg/L equiv. KHP 0~200NTU
COD accuracy ±5%F.S.
COD resolution 0.1mg/L
Turbidity accuracy ±5%F.S.
Turbidity resolution 0.1NTU
pH Probe
Measuring range 0~14pH
Accuracy ±0.1pH
Resolution 0.01pH
ORP Probe
Measuring range -1500mV~+1500mV
Accuracy ±6mV
Resolution 1mV
Ammonia Nitrogen Probe
Measuring range 0~100mg/L or 0~1000mg/L
Accuracy ±10% or ±2mg/L
Resolution 0.1mg/L
Temperature
Measuring range 0~50℃
Accuracy ±0.5℃
Resolution 0.1℃
Other Information of Multi-parameter probe
Output RS-485(Modbus/RTU)
Cleaning method Automatic cleaning
Power consumption 5W@12V
power supply 12VDC±5%
Cable length 5 meters, other length can be customized

Dimension
Note: When the sensor is installed for measurement, use lifting rings or pipe thread installation to avoid direct force on the cable. The sensor connector is M16-5 core waterproof male connector.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2008

  • Total Annual:

    8000000-10000000

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of  measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments .   We have been specializing...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Kacise Optronics Co.,Ltd.
  • i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
  • https://www.fluid-meter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement