Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability | 100+ |
Delivery Time | 5-8 work days |
Packaging Details | 15*20*15cm,0.3kg |
Range | 1m~12m |
Output | 4~20mA/NPN/PNP/RS485 |
Protection class | IP66 |
Power supply | 13-30V |
Material | Nickel plated copper |
Temperature | -25~70℃ |
Accuracy | ≤1 % |
Brand Name | Kacise |
Model Number | KUS3000 |
Place of Origin | China |
Certification | CE |
View Detail Information
Explore similar products
NPT PTFE Ultrasonic Level Sensor Anti Corrosion Chemical Liquid Measurement
PTFE Corrosion Resistant Ultrasonic Level Transducer / RS485 Water Level Sensor
12M range ultrasonic level sensor/anti-corrosion industrial sensor
16mm 40KHz development waterproof ultrasonic sensor receiver sender piezoelectri
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Supply Ability | 100+ |
Delivery Time | 5-8 work days | Packaging Details | 15*20*15cm,0.3kg |
Range | 1m~12m | Output | 4~20mA/NPN/PNP/RS485 |
Protection class | IP66 | Power supply | 13-30V |
Material | Nickel plated copper | Temperature | -25~70℃ |
Accuracy | ≤1 % | Brand Name | Kacise |
Model Number | KUS3000 | Place of Origin | China |
Certification | CE | ||
High Light | Ultrasonic Proximity Distance Meter Sensor ,KUS3000 Series Ultrasonic Transducer Sensor ,Ultrasonic Distance Meter Sensor |
KUS3000 M30-Type3 Ultrasonic Level Meter
1. Dimensional structure
The unit is mm.
2. Electrical interface
Note: This product has two cable specifications, and the cable wiring instructions of the two specifications are as follows:
Type A cable | Type B cable | ||
Pin1 | Brown | Pin1 | Yellow |
Pin2 | White | Pin2 | Black |
Pin3 | Blue | Pin3 | Red |
Pin4 | Black | Pin4 | Green |
The default cable mix is based on the specifications received by the customer
3. Technical parameter
Model | KUS3000 M18 KUS3000 M30-Type1, M30-Type2, M30-Type3 |
Measuring range | 0.15~1m/0.2~2m/0.3~4m/0.4~6m/0.6~12m |
Supply voltage | 13 ... 30 VDC, special wide voltage requirements can be customized |
Output signal | 1.4-20mA/NPN/PNP/TTL; 2. RS485 Modbus. |
No-load current I0 | ≤ 45 mA |
Overload current Ie | 200 mA , reverse polarity protection, short circuit protection |
Power consumption I0 | ≤ 15 mA, sleep state ≤ 1mA, serial port wake-up |
Repeatability | ≤1% |
Temperature compensation range | -40…85°C |
Working environment temperature | -25...70℃ (248...343K) |
Storage temperature | -40...85°C (233...358K) |
Switching frequency f | ≤ 13 Hz high frequency can be customized |
Protection level | IP66, others can be customized |
Shell material | nickel-plated copper, others can be customized |
Connector | V1 connector (M12×1), 4-Pin |
Supply voltage | 3.3-12 DC, ripple 10%SS |
Indicator light
Blue led light | The blue light flashes to indicate that calibration can be performed. Blue and other constants indicate that the power supply of the sensor is normal. The blue light will flash within 5 minutes after the power is turned on, indicating that the user can perform output adjustment and calibration. After 5 minutes, the blue light is always on to indicate that the sensor cannot be receiving Calibration command. . |
Tellow led light | It is used to indicate whether the measured object is detected. During the calibration stage, the yellow light flashes to indicate that the current calibration state is locked, and it can be switched to the next calibration state. |
Red LED light | In normal working state, the red light is not on, and the red light is on to indicate that there is a fault. During the calibration process, the flashing red light indicates that the sensor locks the current echo loss or infinity state, and the user can switch to the next calibration state. |
Note: When the M18 product and M30 product have 4-20mA analog output, the meter connection method is different from that of the 550,600 product. Since the output terminal of the M18 and M30 products is powered by VDD, as shown in Figure 1, the meter should be connected to the power supply port. Between the output terminal and the output terminal, the connection instruction diagram is shown in Figure 2:
Figure 1 Output power supply circuit diagram
Figure 2 Schematic diagram of connection method
4. Order information
KUS | Types of | output | range | describe | |
M18 | M18 housing, maximum measuring range is 1 meter | ||||
M30-Type1 | M30 maximum measuring range is 2 meter | ||||
M30-Type2 | M30 maximum measuring range is 3 meter | ||||
M30-Type3 | M30 maximum measuring range is 6 meter, 8 meters can be customized | ||||
Customized | Shell supports user customization | ||||
NPN | output as NPN | ||||
PNP | output as PNP | ||||
10Vout | The output is analog 0-10V, the power supply requirement is greater than 11V | ||||
5Vout | The output is analog 0-5V, the power supply requirement is greater than 6V | ||||
mAout | The output is analog 4-20mA | ||||
RS485 | The output is RS485 Modbus protocol, please refer to the software interface manual for specific description. | ||||
XXX mm | The customer specifies the linear interval or switch interval, which can be set at the factory | ||||
KUS | M30 | RS485 | 6000mm |
5.Application
Company Details
Business Type:
Manufacturer
Year Established:
2008
Total Annual:
8000000-10000000
Employee Number:
100~150
Ecer Certification:
Verified Supplier
Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing...
Get in touch with us
Leave a Message, we will call you back quickly!