Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability | 100 |
Delivery Time | 5-8 work day |
Packaging Details | each unit has individual box and all boxes are packed in standard packages or customers requests available |
Theory | Ultraviolet fluorescence method |
Accuracy | 1% |
Output signal | RS485 |
Housing Material | POM and 316SS |
Operating Temprature | 0~45℃,<0.2MPa |
Power supply | 12~24VDC ±10% |
Measuring range | 0~20mg/L(0~200%saturation) |
Brand Name | Kacise |
Model Number | KBU601 |
Certification | Intrinsically safe mode E, explosion proof type D, CE |
Place of Origin | China (Mainland) |
View Detail Information
Explore similar products
Intelligent Water Quality Sensor Fiber Optic Chlorophyll Sensor RS485 Transmissi
Aquaculture Fluorescence Dissolved Oxygen Sensor High Accuracy 22mm Casing
Accurate 10% Water Quality Sensor RS485 Output Multi Parameter
Environmentally Friendly COD Sensor / Kws-100 Cod Measurement Instrument
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Supply Ability | 100 |
Delivery Time | 5-8 work day | Packaging Details | each unit has individual box and all boxes are packed in standard packages or customers requests available |
Theory | Ultraviolet fluorescence method | Accuracy | 1% |
Output signal | RS485 | Housing Material | POM and 316SS |
Operating Temprature | 0~45℃,<0.2MPa | Power supply | 12~24VDC ±10% |
Measuring range | 0~20mg/L(0~200%saturation) | Brand Name | Kacise |
Model Number | KBU601 | Certification | Intrinsically safe mode E, explosion proof type D, CE |
Place of Origin | China (Mainland) | ||
High Light | water turbidity sensor ,oil in water sensor |
Online fluorescence dissolved oxygen sensor
1. Applications
The fluorescence dissolved oxygen sensor uses a new generation of fluorescence lifetime technology. Kacise independently develops high performance fluorescent materials. No anaerobic consumption, no flow restrictions, no electricity required. The solution requires no maintenance and calibration, no hydrogen sulphide, and excellent stability. Built-in temperature sensor and automatic temperature compensation. The RS485 output is suitable for networks without a controller.
Features
Technical Specifications
product | Online fluorescence dissolved oxygen sensor | |
principle | Ultraviolet fluorescence method | |
Measuring range | 0~20mg/L | |
Response time | 10 sec | |
accurate | 1% | |
Protection level | IP68 | |
Deepest depth | Underwater 60 meters | underwater 10 meters |
temperature range | 0 ~ 50℃ | |
Output | Support RS-485, MODBUS protocol | |
Power supply | DC 5~12V, current <50mA | |
size | Φ26*177.5 mm | |
Probe cable length | 10 m, customizable 5 m, 15 m and 30 m cable | |
Fluorescent cap life | 1 year | |
Maximum working pressure | 6bar | |
product material | POM or 316 ss |
Installation and electrical connection
1. The temperature sensing part of the installation should be immersed below the liquid level to avoid collision with the surface of the membrane head. The membrane head portion should be protected from deposits.
2. Electrical connection
Red line - power cord (12 ~ 24V)
Black line - ground (GND)
Blue line - 485A
White line - 485B
Bare wire - shield
After wiring is completed, it should be carefully checked to avoid incorrect connections before powering up.
Cable specification: Considering that the cable is immersed in water (including sea water) for a long time or exposed to the air, the cable has certain corrosion resistance. The outer diameter of the cable is Φ6 mm and all interfaces are waterproof.
Company Information
Xi'an Kacise is qualified with ISO 9001-2008, GJB 9001B-2009, CE, intrinsic safety explosion-proof and isolated safety explosion-proof certificates, etc. which ensure that our products comply with international standards.
We have been specializing in manufacturing pressure, level and flow measuring instruments and related products for 10 years. Based on experienced technical and management personnel, through efforts of our entire staff, we have become a professional measuring instrument manufacturer and solution provider. And we are continuously trying to improve product quality.
Currently, Kacise sensors have already been exported to America, Spain, Australia, Chile and 20 other countries and regions, and received many favorable feedbacks. Our overseas distributers are also increasing. We regard “reasonable prices, efficient production time and good after-sales service” as our tenet, and hope to cooperate with more customers for mutual development.
Company Details
Business Type:
Manufacturer
Year Established:
2008
Total Annual:
8000000-10000000
Employee Number:
100~150
Ecer Certification:
Verified Supplier
Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing... Xi'an Kacise Optronics Co.,Ltd. is a professional manufacturer of measuring instruments , located in China xi’an City. Since 2008, Xi'an Kacise focused on the development and production of pressure, level and flow measuring instruments . We have been specializing...
Get in touch with us