Chongqing gold mechnical and electrical equipment Co., Ltd
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability | 5sets/Month |
Delivery Time | 30days |
Packaging Details | Standard Wooden Case |
Name | Single Flame Source Tester |
Standard | ISO 11925-2,DIN4102-1,DIN 53438 |
Power | AC 220V, 50/60Hz, 10A |
Combustion angle | 0 ° (vertical), 45 ° |
Dimension | 400mm(W)*700mm(D)*600(H) |
Function | Building Material Fire test |
Display | LCD touch screen display |
Control System | Programmable Logic Controller (PLC) Control |
Brand Name | GOLD |
Model Number | GD-ISO 11925-2 |
Certification | ISO/CE |
Place of Origin | China |
View Detail Information
Explore similar products
IEC 60695-2-10 Glow Wire Flammability Test Equipment UL 746A Burning Test
IEC 60112 PTI And CTI Comparative Tracking Tester For Solid Insulating Materials
ASTM D1230 45 Degree Flammability Testing Machine Textile Fabric Flame Test
EN 136 Full Face Mask Thermal Radiation Tester Fire Resistance Tester
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Supply Ability | 5sets/Month |
Delivery Time | 30days | Packaging Details | Standard Wooden Case |
Name | Single Flame Source Tester | Standard | ISO 11925-2,DIN4102-1,DIN 53438 |
Power | AC 220V, 50/60Hz, 10A | Combustion angle | 0 ° (vertical), 45 ° |
Dimension | 400mm(W)*700mm(D)*600(H) | Function | Building Material Fire test |
Display | LCD touch screen display | Control System | Programmable Logic Controller (PLC) Control |
Brand Name | GOLD | Model Number | GD-ISO 11925-2 |
Certification | ISO/CE | Place of Origin | China |
High Light | ISO 11925-2 Single Flame Source Test ,Building Materials Single Flame Source Test |
Building Materials ISO 11925-2 Single Flame Source Test Ignitability Apparatus
ISO 11925-2 Single Flame Source Tester Product Introduction:
The flammability tester is designed based on the core principle of Kleinbrenner in Germany. It uses standard flames to conduct vertical direct combustion tests on samples to accurately evaluate the combustion characteristics of building materials. The equipment fully covers the detection requirements of multiple fire protection levels such as B, C, D, E and Bfl, Cfl, Dfl, Efl under the EN 13501-1 standard, integrates intelligent control systems and ergonomic operation interfaces, and provides laboratories with efficient and reliable fire safety testing solutions. The system is also compatible with international mainstream testing standards such as DIN 4102; Part 1; Class B2, equipped with a high-precision flame control system and real-time data acquisition module to ensure that the test process strictly complies with ISO 11925-2 and other specifications. It is suitable for building materials manufacturers, quality inspection agencies and scientific research institutions to conduct standardized testing of material flame retardant properties.
ISO 11925-2 Single Flame Source Tester Standards:
EN ISO 11925-2:Reaction to fire tests -- Ignitability of products subjected to direct impingement of flame -- Part 2: Single-flame source test
DIN 53438:Testing of combustible materials
DIN4102-1:Fire behaviour of building materials and elements Part 1: Classification of building materials Requirements and testing
ISO 11925-2 Single Flame Source Tester Technical Specification:
Product name | ISO 11925 Single Flame Source Tester for Building Materials |
Standard | ISO11925-2; DIN53438; DIN4102 |
Application | Building Materials; Rail; IMO |
Weight | About 50kg |
Dimension | 400mm(W)*700mm(D)*600(H) |
Power | AC 220V, 50/60Hz, 10A |
ISO 11925-2 Single Flame Source Tester Steps::
1. Prepare the test sample and fix it on the test stand.
2. Pre-treat the test sample so that it reaches the humidity and temperature required by the standard.
3. Connect the combustion head and data acquisition system of the test equipment.
4. Start the test and record the parameters during the test.
5. Analyze the test results to evaluate the combustion performance of the floor covering.
6. After the test is complete, shut down the unit and perform routine maintenance.
ISO 11925-2 Single Flame Source Tester Daily maintenance:
1. Regularly check the power line, data line and the interface of the combustion head of the test equipment to ensure that they are stable and reliable.
2. Regularly clean the combustion head and data acquisition system of the test equipment to keep them clean and hygienic.
3. Regularly calibrate test equipment to ensure the accuracy and reliability of test results.
ISO 11925-2 Single Flame Source Tester Precautions for using materials:
1. Make sure the test sample meets the standard requirements, including humidity, temperature, size, etc.
2. During the test, it is strictly forbidden to leave the test site or turn off the test equipment.
3. During the test, attention should be paid to the safety of the fire source, and the test site should be kept dry and clean.
4. When using the test equipment, follow the requirements of the operation manual to ensure the smooth progress of the test process.
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
2008
Ecer Certification:
Verified Supplier
Since 2008, GOLD has developed 70 kinds of fire testing instruments and served many industries such as building materials, aviation, rails, IMO, wire & cable, safety protection, and so on. Quality and Certification: We always adhere to a strict quality control system, and all produ... Since 2008, GOLD has developed 70 kinds of fire testing instruments and served many industries such as building materials, aviation, rails, IMO, wire & cable, safety protection, and so on. Quality and Certification: We always adhere to a strict quality control system, and all produ...