China Diagnostic Kit for Cystain C Rapid Test Kit IFA Colloidal Gold IVD Blood
China Diagnostic Kit for Cystain C Rapid Test Kit IFA Colloidal Gold IVD Blood

  1. China Diagnostic Kit for Cystain C Rapid Test Kit IFA Colloidal Gold IVD Blood
  2. China Diagnostic Kit for Cystain C Rapid Test Kit IFA Colloidal Gold IVD Blood

Diagnostic Kit for Cystain C Rapid Test Kit IFA Colloidal Gold IVD Blood

  1. MOQ: 1000
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T
Supply Ability 20000 Kits per Week
Delivery Time 7 Days
Packaging Details Colorful Paper Box
Product Name CystatinC Rapid Test Kit
Type One Step Assay
Reactivity Human
Formal Name CystatinC
Package 25 Tests
Storage At Room Temperature
Usage Renal Injury
Keywords High Stability, High Sensitivity, High Accuracy
Brand Name WWHS
Model Number Cys-C
Certification CE
Place of Origin CN

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 20000 Kits per Week
Delivery Time 7 Days Packaging Details Colorful Paper Box
Product Name CystatinC Rapid Test Kit Type One Step Assay
Reactivity Human Formal Name CystatinC
Package 25 Tests Storage At Room Temperature
Usage Renal Injury Keywords High Stability, High Sensitivity, High Accuracy
Brand Name WWHS Model Number Cys-C
Certification CE Place of Origin CN
High Light IFA Cystain C Rapid Test KitBlood Cystain C Rapid Test KitColloidal Gold CystatinC Rapid Test Kit

【Product name】 CysC.pdf

Carcinoembryonic Antigen (CEA) Rapid Quantitative Test(Fluorescence immunoassay)

 

 

 

【Intended use】

This kit is used for quantitative determination of CEA in human whole blood, plasma and serum.

Carcinoembryonic antigen (CEA) is a tumor associated antigen, first described in 1965 by Gold and Freedman1. It is a cell-surface glycoprotein with a molecular weight of 180-200kD, that occurs in high levels in colon epithelial cells during embryonic development. Levels of CEA are significantly lower in colon tissue of adults, but can become elevated when inflammation or tumours arise in any endodermal tissue, including the gastrointestinal tract, respiratory tract, pancreas and breast.

An over expression of CEA protein has been detected in a variety of adenocarcinomas, including gastric, pancreatic, small intestine, colon, rectal, ovarian, breast, cervical and non-small-cell lung cancers. CEA is also expressed by epithelial cells in several non-malignant disorders, including diverticulitis, pancreatitis, inflammatory bowel disease, cirrhosis, hepatitis, bronchitis and renal failure and also in heavy smokers.

Therefore CEA should not be regarded as a tumour-specific marker for the screening of a general population for undetected cancers. However, the determination of CEA levels provides important information about patient prognosis, recurrence of tumours after surgical removal and effectiveness of therapy.

 

 

 

 

【Components】

Name Quantity Component
Test cards 25 It is composed of fluorescent pad (coated with fluorescent labeled CEA monoclonal mouse antibody), nitrocellulose membrane (coated with CEA monoclonal mouse antibody and Goat anti mouse IgG antibody), absorbent paper and backing
Sample diluent 25(300μL/tube) Phosphate buffer
ID card 1 With specific stand curve file
 

The components in different batches of kits cannot be used interchangeably.

【Storage conditions and validity】

The kit should be stored at 4℃~30℃, out of direct sunlight. It is valid for 18 months. The test card should be used within 15 minutes after unsealing under the environment of 15℃~30℃ and 20% ~ 90% relative humidity.

The production date, batch number and expiration date are shown in the outer package of the product.

【Applicable instruments】

NIR-1000 dry fluoroimmunoassay analyser produced by WWHS Biotech. Inc.

 

 

  1.  

【Procedure】

  1. Before the test, please read the instructions completely. If the test card and sample are stored in cold storage, they should be balanced at room temperature (15-30)℃ for not less than 30min before use.
  2. Start NIR-1000 dry fluoroimmunoassay analyser according to the instruction manual of the instrument, and carry out quality control verification according to the instruction manual of the instrument(Note: the reagent has been calibrated in advance, and the calibration curve parameters of each batch of reagent have been stored in the information card. The information card is inserted before use, so it is not necessary to calibrate again, and the test can be carried out only after the quality control is passed. Otherwise, the cause should be found out before testing.)
  3. Remove the test card from the aluminum foil bag and use it within 15 minutes.
  4. Place the test card on a clean horizontal table and mark it horizontally.
  5. Mix 100µL of patient sample with 300µL of sample diluent. Apply 100µL of diluted samples to the well of the test card.
  6. Insert the test card into NIR-1000 dry fluoroimmunoassay analyser, read and record the results at 10 minutes after addition of samples, then dispose of used test appropriately.

 

 

  1.  

【Limitations of methods】

  1. This kit is only used to detect human plasma/whole blood samples
  2. Due to the limitations of immunoassay methods of antigen and antibody reaction, the results cannot be used as the only basis for clinical diagnosis, but should be evaluated with all the existing clinical and experimental data.
  3. The content of triglyceride in the sample shall not exceed 15mg/ml, the content of hemoglobin shall not exceed 5mg/ml, and the content of bilirubin shall not exceed 0.5mg/ml, and the relative deviation of the test results shall not exceed ±15%.
  4. When the concentration of CEA in the sample is less than 20000ng/ml, there is no hook effect.
  5. HAMA effect was not produced when the concentration of human anti rat in the sample was less than 50ng/ml.
  6. When RF concentration in the sample is less than 2000IU/ml, the relative deviation of the test results is within ±15%.

【Performance】

1. Limits of detection

No more than 1ng /ml.

2. Accuracy

The relative deviation from the target value is within ±15%.

3. Precision

The within and between assay coefficient of variations are within 15%.

4. Linear range

Within the linear range (1 ~ 500ng/ml), the linear correlation coefficient R≥0.990.

 

 

 

 

 

 

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2016

  • Total Annual:

    3000-5000

  • Employee Number:

    50~80

  • Ecer Certification:

    Site Member

As A Fast-Growing Biotechnology Company, WWHS Biotech.Inc(exclusive marketed by Dawin) Dedicate To The Development Of World-Class Bio-Detection Technologies That Meet The Ever-Increasing Demands On Clinical Diagnostics. We Focus On Developing Cost-Effective And Precise Rapid Diagnostic Products... As A Fast-Growing Biotechnology Company, WWHS Biotech.Inc(exclusive marketed by Dawin) Dedicate To The Development Of World-Class Bio-Detection Technologies That Meet The Ever-Increasing Demands On Clinical Diagnostics. We Focus On Developing Cost-Effective And Precise Rapid Diagnostic Products...

+ Read More

Get in touch with us

  • Reach Us
  • WWHS Biotech.Inc(exclusive marketed by Dawin)
  • Rm 505, 1st Building, Shenzhen Biomedicine Innovation Industrial Park, No. 14th, Jinhui Road, East Jinxiu Road, Kengzi Street, Pingshan District, Shenzhen
  • https://www.fiapoct.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement