Safe load limit (EL) & Breaking 10ad(Ed) 150 &250 %ofEmax
Creep(dcr) over 30 min ± 0.030 %ofCn
Rated Excitation 5---15
Ip Protection Standard IP68
Hysteresis error (dhy) ± 0.0270 %ofCn
Accuracy class to OIML R60 C2,C3
Non-linearity(dlin) ± 0.0250 %ofCn
Material Stainless Or Alloy Steel +Stainless Steel
Brand Name INNTRONIC
Model Number IN-RC3
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Safe load limit (EL) & Breaking 10ad(Ed) 150 &250 %ofEmax Creep(dcr) over 30 min ± 0.030 %ofCn
Rated Excitation 5---15 Ip Protection Standard IP68
Hysteresis error (dhy) ± 0.0270 %ofCn Accuracy class to OIML R60 C2,C3
Non-linearity(dlin) ± 0.0250 %ofCn Material Stainless Or Alloy Steel +Stainless Steel
Brand Name INNTRONIC Model Number IN-RC3
Place of Origin China
High Light IP68 Column Load CellHeavy Duty Column Load Cell150% Column Load Cell

Product Description:

Designed for use in a wide range of temperatures, the Column-Based Load Cell can operate in service temperatures ranging from -30...+70℃ (Btu). Whether you’re weighing trucks in the middle of a scorching summer or a freezing winter, this load cell can handle it with ease.

Thanks to its IP68 protection standard, the Column-Based Load Cell is the perfect choice for outdoor applications. It’s completely dust-tight and can withstand even the harshest weather conditions, making it the ideal load cell for use in truck scales.

Overall, if you’re looking for a high-quality and reliable load cell for your truck scale, the Column-Based Load Cell is the way to go. With its advanced features and rugged design, it’s sure to meet all your weighing needs with ease.

 

Features:

  • Product Name: Column-Type Load Cell
  • Load-Measuring Sensor
  • Force-Sensing Transducer
  • Non-linearity(dlin): ± 0.0250 %ofCn
  • Hysteresis error (dhy): ± 0.0270 %ofCn
  • Material: Stainless Or Alloy Steel +Stainless Steel
  • Accuracy class to OIML R60: C2,C3
  • Temperature effect on zero balance (TKo): ± 0.02 % OfCn/10K
 

Technical Parameters:

Product Attribute Value
Product Name Column-Type Load Cell
Product Type Force Measuring Transducer, Force-Sensing Transducer
Safe Load Limit (EL) 150% - 250% of Emax
Accuracy Class C2, C3 (OIML R60)
Material Stainless or Alloy Steel + Stainless Steel
Capacity 5T, 10T, 20T, 30T
Rated Excitation 5 - 15
Application Truck Scale
Service Temperature Range (Btu) -30...+70℃
IP Protection Standard IP68
Temperature Effect on Zero Balance (TKo) ± 0.02% of Cn/10K
Hysteresis Error (dhy) ± 0.0270% of Cn
 

Applications:

The IN-RC3 Column Load Cell is designed for use in a range of applications, including industrial automation, logistics, and material handling. It can be used to measure the weight of goods in transportation, the force exerted on machinery during operation, and the weight of materials in storage. The load cell is ideal for use in harsh environments, as it is resistant to corrosion and damage from impact.

The load cell is also suitable for use in the construction industry, where it can be used to measure the weight of building materials, such as concrete and steel beams. It can also be used to measure the force exerted by heavy machinery, such as cranes and excavators.

The IN-RC3 Column Load Cell is designed with safety in mind, with a safe load limit (EL) of 150% of Emax and a breaking 10ad(Ed) of 250% of Emax. This ensures that the load cell can withstand heavy loads without compromising on accuracy. The load cell also has a hysteresis error (dhy) of ± 0.0270% of Cn, ensuring that measurements are accurate and consistent.

The accuracy class of the load cell is to OIML R60 C2, C3, making it suitable for use in a range of applications where precise measurements are required. The load cell is easy to install and can be used with a range of different equipment, making it a versatile force measuring transducer that can be used in a variety of scenarios.

Overall, the IN-RC3 Column Load Cell is a reliable and accurate force measuring transducer that is suitable for use in a wide range of applications. Its durability, accuracy and versatility make it an ideal choice for any scenario where accurate weight measurement is required.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller

  • Year Established:

    2012

  • Total Annual:

    1500000-2000000

  • Ecer Certification:

    Site Member

INNOVATION ELECTRONIC CO..,LTD Focus on Weighing and Static solution in Packing industry!   In the past tens of years, we established very good relationship with wide range of suppliers and customers in weighing and static products especially in packing industry and also investigated in o... INNOVATION ELECTRONIC CO..,LTD Focus on Weighing and Static solution in Packing industry!   In the past tens of years, we established very good relationship with wide range of suppliers and customers in weighing and static products especially in packing industry and also investigated in o...

+ Read More

Get in touch with us

  • Reach Us
  • Innovation Electronic Co.,Ltd
  • #201,Shunda Road, Yuhang Economic Area, Hangzhou,China
  • https://www.columnloadcell.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement