I. Key Equipment Structure and Operating Principle
1. Spray Tower (Patent CN222788898U)
Tower Structure: A built-in filter intercepts large particles, and a waste liquid treatment chamber collects waste liquid after the neutralization reaction.
Spray System: Multi-stage atomizing nozzles evenly spray the absorbent liquid, while countercurrent contact with the exhaust gas achieves efficient purification.
Demisting Device: A wire mesh demister reduces exhaust gas humidity to ≤50 mg/m³.
2. RTO Equipment
Three-tower Regenerator: Ceramic regenerators alternately preheat the exhaust gas (to over 800°C) and recover the heat, reducing energy consumption by over 30%.
Oxidation Chamber: High-temperature decomposition of VOCs with a residence time of ≥1 second ensures complete mineralization of organic matter.
3. Electrostatic Fume Removal Equipment
High-voltage electrostatic field: Corona discharge charges particulate matter, and dust collecting plates capture the dust, achieving a purification efficiency of ≥99%.
Modular Design: The plates can be quickly disassembled and cleaned, reducing maintenance costs by 40%.
II. Technical parameters and performance
Equipment Type | Treatment Efficiency | Applicable Concentrations | Operating Temperature |
Activated carbon adsorption tower | 85-95% | Low VOCs (<500ppm) | Normal |
RTO thermal storage combustion unit | ≥99% | High VOCs (>1000ppm) | 760-850°C |
Electrostatic precipitator | ≥99% | Dust (1-1000mg/m³) | ≤300°C |
Spray tower | 70-90% | Acidic Gases (pH 1-12) | Normal to 150°C |
III. Application Scenarios and Adaptation Solutions
Automotive paint shops: RTO treatment of high-concentration organic waste gas (such as benzene series), with a purification rate of ≥99%;
Electroplating/pickling lines: Spray tower + activated carbon adsorption in series to neutralize acidic gases and adsorb cyanide;
Petrochemical industry: Zeolite rotor concentration + RCO catalytic combustion to treat high-volume, low-concentration VOCs;
Food processing plants: Biofilters to degrade fermentation waste gas (such as hydrogen sulfide and ammonia).
IV. Equipment Selection and Operation and Maintenance Key Points
1. Selection Basis
Waste gas composition (particulate matter, VOCs, acidic gases) and concentration;
Emission standards (such as the "Comprehensive Emission Standard for Air Pollutants" GB 16297-1996);
Energy consumption and operation and maintenance costs (RTO/RCO are suitable for continuous production, while activated carbon adsorption is suitable for intermittent operation). 2. Operation and Maintenance Management
Activated Carbon Replacement: Check the adsorption saturation rate every 3-6 months and replace any depleted carbon layers.
RTO Ceramic Body Cleaning: Remove carbon deposits on the thermal storage body annually to maintain thermal efficiency.
Spray Liquid Monitoring: Real-time pH control (e.g., NaOH solution pH ≥ 10).
I. Exhaust Gas Collection System
1. Gas Collection Hood
Adopts a closed or side-suction design, covering the pollution source (such as a reactor or oxidation tank). Collection efficiency is related to wind speed (0.5-1.5 m/s) and material (316L stainless steel, fiberglass).
Multiple-point gas collection hoods in parallel are suitable for open pollution sources.
2. Exhaust Ducts
Made of fiberglass/PVC, with a diameter of 150-500 mm. The layout should minimize right-angle bends to reduce air resistance.
High-temperature ducts should be insulated with aluminum silicate fiber to prevent heat loss.
II. Pretreatment Unit
1. Dry Filter
Metal filter (pore size ≤ 2 mm) intercepts large dust particles and droplets, protecting downstream equipment.
Can be combined with a cyclone dust collector to increase dust filtration efficiency to ≥ 90%.
2. Condenser (Optional)
For high-temperature exhaust gases (≤ 150°C), heat exchange is used to cool them to 40-60°C, reducing exhaust volume.
III. Core Treatment Equipment
1. Combustion Equipment
RTO (Regenerative Thermal Oxidation) Unit: Three ceramic regenerators alternately preheat exhaust gas to 760-850°C, oxidizing and decomposing organic matter with a heat recovery rate of ≥95%.
A circulating fan (centrifugal blower) provides power, with a flow rate of 2,000-50,000 m³/h.
Catalytic Combustion Unit (RCO) Unit: Precious metal catalysts decompose VOCs at 250-400°C, achieving a purification rate of ≥95%.
2. Adsorption Unit
Activated Carbon Adsorption Tower: Honeycomb activated carbon absorbs VOCs and odor molecules with an adsorption efficiency of ≥85%. The carbon layer requires regular replacement.
Zeolite Rotor: Targets high-volume, low-concentration exhaust gas, concentrating VOCs through adsorption and desorption. 3. Dust Removal Equipment
Bag-type dust collector: Filter bags intercept dust particles. The filter chamber includes an air inlet, a dust cleaning system, and an electronic control module.
Electrostatic precipitator: A high-voltage electrostatic field absorbs dust. The modular design allows for rapid maintenance.
4. Biological Treatment Equipment
Biological filter: Microorganisms degrade low-concentration organic waste gas. Includes an aeration tank, hydrolysis tank, and sedimentation tank.
IV. Power System
1. High-temperature-resistant fan
The impeller (alloy/fiberglass) drives the air flow, with a pressure of 1200-2500 Pa.
The frequency converter adjusts the air volume to match the treatment requirements.
2. Motor
Provides power, with power adapted to the required air volume and pressure, reducing energy consumption.
V. Emission Control System
1. Chimney
Height ≥ 15m to ensure exhaust gas dispersion and comply with the "Comprehensive Emission Standards for Air Pollutants."
Built-in online monitors (VOCs, dust concentration) provide real-time data feedback. 2. Electronic Control System
The PLC controller links the fan, combustion device, and monitoring module for automated operation.
A fault alarm function ensures equipment safety.
1.High cost performance: Based on the customer's product positioning and development strategy, and with economic affordability as the foundation, we achieve the best cost performance.
2.The advanced and meticulous design concept of the equipment, along with the highly automated industrial equipment, showcases the image of a modern and advanced enterprise.
3. It has high adaptability, meeting the current production requirements and reserving room for development, taking into account the needs of increased production and improved quality in the future.
4.Quality compliance strictly adheres to the ISO900 quality management system, with every minute detail of the entire equipment installation being strictly controlled.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Exporter,Seller
Year Established:
2004
Total Annual:
10000000-20000000
Employee Number:
100~200
Ecer Certification:
Verified Supplier
Domestic large-scale coating equipment, intelligent equipment, and environmental protection equipment production enterprises-Zhejiang Huier Coating Environmental Protection Equipment Co., Ltd has 37 years of experience industry team in the powder coating equipment,intelligent equipment and environme... Domestic large-scale coating equipment, intelligent equipment, and environmental protection equipment production enterprises-Zhejiang Huier Coating Environmental Protection Equipment Co., Ltd has 37 years of experience industry team in the powder coating equipment,intelligent equipment and environme...
Get in touch with us