China Procalcitonin PCT Fluorescence Immunoassay Test Convenient
China Procalcitonin PCT Fluorescence Immunoassay Test Convenient

  1. China Procalcitonin PCT Fluorescence Immunoassay Test Convenient

Procalcitonin PCT Fluorescence Immunoassay Test Convenient

  1. MOQ: N/A
  2. Price: Negotiation
  3. Get Latest Price
Supply Ability 10 M tests/month
Delivery Time 2-4 Weeks
Packaging Details 10T/25T
Product Convenient Procalcitonin (PCT) Diagnostic Test Kit Use By Citest fluorescence Immunoassay In Whole Blood/Serum /Plasma
Cat. No. FI-PCT-402
Principle Fluorescence Immunoassay
Format Cassette
Specimen WB/S/P
Certificate CE
Reading Time 15 minutes
Pack 10T/25T
Storage Temperature 4-30℃
Shelf Life 2 Years
Linearity range 0.1~50 ng/ml , R≥0.990
Cut-Off 0.5 ng/mL
Precision C.V. ≤15%
Accuracy The test deviation is≤±15%
Brand Name Citest
Model Number FI-PCT-402
Certification CE
Place of Origin -

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Supply Ability 10 M tests/month Delivery Time 2-4 Weeks
Packaging Details 10T/25T Product Convenient Procalcitonin (PCT) Diagnostic Test Kit Use By Citest fluorescence Immunoassay In Whole Blood/Serum /Plasma
Cat. No. FI-PCT-402 Principle Fluorescence Immunoassay
Format Cassette Specimen WB/S/P
Certificate CE Reading Time 15 minutes
Pack 10T/25T Storage Temperature 4-30℃
Shelf Life 2 Years Linearity range 0.1~50 ng/ml , R≥0.990
Cut-Off 0.5 ng/mL Precision C.V. ≤15%
Accuracy The test deviation is≤±15% Brand Name Citest
Model Number FI-PCT-402 Certification CE
Place of Origin -
High Light PCT Fluorescence Immunoassay TestProcalcitonin Fluorescence Immunoassay Test50ng/ml Procalcitonin PCT test
Product features Parameters
Principle Fluorescence Immunoassay
Format Cassette
Specimen WB/S/P
Certificate CE
Reading Time 15 minutes
Pack 10T/25T
Storage Temperature 4-30℃
Shelf Life 2 Years
Cut-Off 0.5 ng/mL

 

Convenient Procalcitonin (PCT) Diagnostic Test Kit Use By Citest fluorescence Immunoassay In Whole Blood/Serum /Plasma

 

A test for measuring Procalcitonin (PCT) in whole blood /serum /plasma with the use of Citest TM fluorescence Immunoassay Analyzer. For professional in vitro diagnostic use only.

 

Application:

 

The PCT Test Cassette (Whole Blood/Serum/Plasma) is based on Fluorescence immunoassay for the quantitative detection of human Procalcitonin in whole blood, serum or plasma as an aid in the diagnosis of inflammatory conditions.

 

Description:

 

Procalcitonin (PCT) is a small protein that comprises 116 amino acid residues with a molecular weight of approximately 13 kDa which was first described by Moullec et al. in 1984. PCT is produced normally in C-cells of the thyroid glands. In 1993, the elevated level of PCT in patients with systemic infection of bacterial origin was reported and PCT is now considered to be the main marker of disorders accompanied by systemic inflammation and sepsis.

 

The diagnostic value of PCT is important due to the close correlation between PCT concentration and the severity of inflammation. It was shown that “inflammatory” PCT is not produced in C-cells. Cells of neuroendocrine origin are presumably the source of PCT during inflammation.

Features

【PERFORMANCE CHARACTERISTICS】

1. Accuracy

The test deviation is≤±15%.

2. Assay Range and Detection Limit

Assay Range: 0.1 – 50 ng/mL

Minimum Detection Limit (Analytical Sensitivi ty): 0.1 ng/mL

3. Linearity range

0.1~50 ng/ml , R≥0.990

4. Precision

C.V. ≤15%

 

 

Fast Result (15 minutes)

Simple Operation (Less Training Required)

Objective (Results Read by Analyzer)

Stringent Quality Control Insure High Accuracy

User-friendly (Simple Plug & Play Operation)

High Efficiency (Both STAT Testing and Batch Testing)

 

How to use?

 

Refer to Citest TM Fluorescence Immunoassay Analyzer Operation Manual for the complete instructions on use of the Test. The test should be in room temperature.

 

1. Turn on the Analyzer power. Then according to the need, select “Standard test” or “Quick test” mode.

 

2. Take out the ID card and insert it into the Analyzer ID Card Slot.

 

3. Serum or plasma: Pipette 50 μL serum or plasma into the buffer tube, mix the specimen and the buffer well.

Whole blood: Pipette 75 μL whole blood into the buffer tube; mix the specimen and the buffer well.

 

4. Pipette 75 μL diluted sample into the sample well of the cassette. Start the timer at the same time.

 

5. There are two test modes for Citest TM Fluorescence Immunoassay Analyzer, Standard Test mode and Quick Test mode.

 

Please refer to the user manual of Citest TM Fluorescence Immunoassay Analyzer for details.

“Quick test” mode:After 15 minutes of adding sample,Insert the test cassette into the Analyzer and click “QUICK TEST”, fill the test information and click "NEW TEST" immediately. The Analyzer will automatically give the test result after a few seconds.

 

“Standard test” mode:Insert the test cassette into the Analyzer immediately after adding specimen, click “STANDARD TEST”, fill the test information and click "NEW TEST" at the same time. The Analyzer will automatically countdown 15 minutes. After the countdown, the Analyzer will give the result at once.

 

 

 

INTERPRETATION OF RESULTS
Results read by Citest TM Fluorescence Immunoassy Analyzer.
The result of tests for PCT is calculated by Citest TM Fluorescence Immunoassay Analyzer and display the result on the screen. For additional information, please refer to the user manual of Citest TM Fluorescence Immunoassay Analyze.
Linearity range of Citest TM PCT is 0.1-50 ng/mL.
Reference range: <0.1ng/ml.

 

Order Information

 

Catalogue Number Item Name Sample Test Range KIT size
FI-PCT-402 PCT Test Cassette WB/S/P 0.1~50 ng/ml

10T/25T

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Trading Company

  • Total Annual:

    80000000-100000000

  • Employee Number:

    500~10000

  • Ecer Certification:

    Verified Supplier

CITEST DIAGNOSTICS INC., an emerging In Vitro Diagnostics company based in Canada, is experiencing growth on a global scale, engaging in multinational operations. CITEST was founded by highly experienced IVD industry professionals with proven track records building and growing successful companies. ... CITEST DIAGNOSTICS INC., an emerging In Vitro Diagnostics company based in Canada, is experiencing growth on a global scale, engaging in multinational operations. CITEST was founded by highly experienced IVD industry professionals with proven track records building and growing successful companies. ...

+ Read More

Get in touch with us

  • Reach Us
  • CITEST DIAGNOSTICS INC.
  • 170-422, Richards Street, Vancouver BC V6B 2Z4, CANADA
  • https://www.citesttestkit.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement