Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"MTZ Rapid Test Dipstick Urine specimen, Desmethylmirtazapine detect, Drug Abuse","imgUrl":"https:\/\/img.ismap.com\/nimg\/9f\/be\/bfa957aa2c3c6f82461f3ab765ca-200x200-1\/mtz_rapid_test_dipstick_urine_specimen_2c_desmethylmirtazapine_detect_2c_drug_abuse.jpg","attrs":{"Brand Name":"Citest","Model Number":"DMTZ-101\/111","Certification":"CE","Place of Origin":"-"}}
{"title":"ALP Rapid Test Cassette Urine 100ng\/M Cut-Off Detection Of Alprazolam Xanax","imgUrl":"https:\/\/img.ismap.com\/nimg\/82\/58\/3d3359fafe92f628e1527b752a49-200x200-1\/alp_rapid_test_cassette_urine_100ng_2fm_cut_off_detection_of_alprazolam_xanax.jpg","attrs":{"Brand Name":"Citest","Model Number":"DALP-102","Certification":"CE","Place of Origin":"-"}}
{"title":"2000ng\/ML Gabapentin GAB Drug Abuse Test Kit One Step Rapid Test High Accurate","imgUrl":"https:\/\/img.ismap.com\/nimg\/af\/06\/d66eac3546b3c4bc37cd4943eb7b-200x200-1\/2000ng_2fml_gabapentin_gab_drug_abuse_test_kit_one_step_rapid_test_high_accurate.jpg","attrs":{"Brand Name":"Citest","Model Number":"DGAB-102\/114\/101","Certification":"CE","Place of Origin":"-"}}
{"title":"CE Kratom Drug Abuse Test Kit Dipstick Rapid Test Cassette Urine","imgUrl":"https:\/\/img.ismap.com\/nimg\/63\/97\/483a9881e6da5ae75c458d815b47-200x200-1\/ce_kratom_drug_abuse_test_kit_dipstick_rapid_test_cassette_urine.jpg","attrs":{"Brand Name":"Citest","Model Number":"DKRA-102\/114\/101","Certification":"CE","Place of Origin":"-"}}
{"title":"Drug Abuse Rapid Accurate Reliable Detection SCOP Kit Urine Test Type","imgUrl":"https:\/\/img.ismap.com\/nimg\/f0\/c1\/a4ddbf8f570c26c1414fce99b2ba-200x200-1\/drug_abuse_rapid_accurate_reliable_detection_scop_kit_urine_test_type.jpg","attrs":{"Brand Name":"CITEST","Model Number":"DSC-CT102","Certification":"CE\/FDA","Test Type":"Urine"}}
{"title":"Urine Drug Abuse FKET Test Kit High Accuracy Sensitivity Specificity","imgUrl":"https:\/\/img.ismap.com\/nimg\/f0\/c1\/a4ddbf8f570c26c1414fce99b2ba-200x200-1\/urine_drug_abuse_fket_test_kit_high_accuracy_sensitivity_specificity.jpg","attrs":{"Brand Name":"CITEST","Model Number":"DFKE-CT102","Sensitivity":"1000 Ng\/mL","Test Substance":"F-Ketamine"}}
{"title":"300ng\/ML 7-ACL Dispoable Drug Abuse Test Kit OEM 7 Aminoclonazepam Drug Test","imgUrl":"https:\/\/img.ismap.com\/nimg\/df\/a8\/5597f80e3a9f6190da0289c76e9c-200x200-1\/300ng_2fml_7_acl_dispoable_drug_abuse_test_kit_oem_7_aminoclonazepam_drug_test.jpg","attrs":{"Brand Name":"Citest","Model Number":"DACL-102\/111\/114","Certification":"CE","Place of Origin":"-"}}
MTZ Rapid Test Dipstick Urine specimen, Desmethylmirtazapine detect, Drug Abuse Test Kit
Cat. No.
DMTZ-101/111
Principle
Chromatographic Immunoassay
Format
Dipstick
Specimen
Urine
Certificate
CE
Reading Time
5 minutes
Pack
40T
Sensitivity
93.3%
Specificity
95.6%
Accuracy
94.9%
Cut-Off
500 ng/mL
Brand Name
Citest
Model Number
DMTZ-101/111
Certification
CE
Place of Origin
-
MTZ Rapid Test Dipstick Urine specimen, Desmethylmirtazapine detect, Drug Abuse Test Kit
Product:
MTZ Rapid Test Dipstick Urine Specimen, Desmethylmirtazapine Detect, Drug Abuse Test Kit
Principle:
Chromatographic Immunoassay
Specimen:
Urine
Reading Time:
5 Minutes
Storage Temperature:
2-30°C
Sensitivity:
93.30%
Accuracy:
94.90%
Cat No.:
DMTZ-101/111
Format:
Cassette
Certificate:
CE
Pack:
40T/50T
Shelf Life:
2 Years
Specificity:
95.60%
Cut-Off:
500 Ng/mL
A rapid test for the qualitative detection of Desmethylmirtazapine in human urine. For professional in vitro diagnostic use only.
INTENDED USE
The MTZ Rapid Test Dipstick (Urine) is a rapid chromatographic immunoassay for the detection of Desmethylmirtazapine in urine at a cut-off concentration of 500 ng/ml. This test will detect other related compounds, please refer to the Analytical Specificity table in this package insert.
This assay provides only a qualitative, preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS) is the preferred confirmatory method. Clinical consideration and professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are used.
PRINCIPLE
The MTZ Rapid Test Dipstick (Urine) is an immunoassay based on the principle of competitive binding. Drugs which may be present in the urine specimen compete against the drug conjugate for binding sites on the antibody.
During testing, a urine specimen migrates upward by capillary action. Desmethylmirtazapine, if present in the urine specimen below the cut-off level, will not saturate the binding sites of the antibody in the test. The antibody coated particles will then be captured by immobilized Desmethylmirtazapine-protein conjugate and a visible colored line will show up in the test line region.
The colored line will not form in the test line region ifthe Desmethylmirtazapine level exceeds the cut-off level, because it will saturate all thebinding sites of anti-desmethylmirtazapine antibody.A drug-positive urine specimen will not generate a colored line in the test line regionbecause of drug competition, while a drug-negative urine specimen or a specimencontaining a drug concentration less than the cut-off will generate a line in the test lineregion.
To serve as a procedural control, a colored line will always appear at the control line region indicating that proper volume of specimen has been added and membrane wicking has occurred.
DIRECTIONS FOR USE
Allow the test, urine specimen, and/or controls to reach room temperature (15-30 °C) prior to testing.
1. Bring the pouch or canister to room temperature before opening it. Remove the test dipstick from the sealed pouch or closed canister and use it within one hour.
2. With the arrow pointing toward the urine specimen, immerse the test dipstick vertically in the urine specimen in such a way that urine does not cross MAX line on the test Dipstick for 10-15 seconds. See the illustration below.
3. Place the Test Dipstick on a non-absorbent flat surface, start the timer and wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10 minutes.
INTERPRETATION OF RESULTS
(Please refer to the illustration above)
NEGATIVE:* Two colored lines appear. One colored line should be in the control line region (C), and another colored line should be in the test line region (T). This negative result indicates that the Desmethylmirtazapine concentration is below the detectable cut-off level.
*NOTE: The shade of color in the test line region (T) may vary, but it should be considered negative whenever there is even a faint colored line.
POSITIVE: One colored line appears in the control line region (C). No line appears in the test line region (T). This positive result indicates that the Desmethylmirtazapine concentration exceeds the detectable cut-off level.
INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test. If the problem persists, discontinue using the test kit immediately and contact local distributor.
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer,Exporter,Trading Company
Total Annual:
80000000-100000000
Employee Number:
500~10000
Ecer Certification:
Verified Supplier
CITEST DIAGNOSTICS INC., an emerging In Vitro Diagnostics company based in Canada, is experiencing growth on a global scale, engaging in multinational operations. CITEST was founded by highly experienced IVD industry professionals with proven track records building and growing successful companies.
... CITEST DIAGNOSTICS INC., an emerging In Vitro Diagnostics company based in Canada, is experiencing growth on a global scale, engaging in multinational operations. CITEST was founded by highly experienced IVD industry professionals with proven track records building and growing successful companies.
...