Payment Terms | L/C, D/P, T/T, Western Union, Paypal, Credit card |
Supply Ability | 28000 sets per week |
Delivery Time | 10-15 working days |
Packaging Details | Plywood outer box with bubble bag or paper |
Storage Pressure | 4.2 MPa |
Spraying Time | ≤10s |
Filling Density | ≤950kg/m3 |
Nominal Pressure | 5.3MPa |
Test Pressure | 8.4MPa |
Working Power | DC 24V 1.6A |
Working Temperature | 0℃~50℃ |
Protected Zone Range | Proportion: ≤800m² ; Volume: ≤3600m³ |
Starting Mode | Automatic, Electrical Manual, Mechanical Manual |
Cylinder Volume | 40L、70L、100L、120L、150L、180L |
Brand Name | Air Giant |
Model Number | QMP40/4.2, QMP70/4.2, QMP100/4.2, QMP120/4.2, QMP150/4.2, QMP180/4.2 |
Certification | CAL,CMA,CNAS,ILAC-MRA,CCC |
Place of Origin | China |
View Detail Information
Explore similar products
Environment-friendly FM200 Fire Suppression System Without Pollution For Archive
800m² FM200 Fire Suppression System Automatic Fire Extinguisher 4.2MPa
Non Corrosive FM200 Fire Suppression System Without Pollution For Data Center
Fm200 Gas System Without Pollution for Storage Room
Product Specification
Payment Terms | L/C, D/P, T/T, Western Union, Paypal, Credit card | Supply Ability | 28000 sets per week |
Delivery Time | 10-15 working days | Packaging Details | Plywood outer box with bubble bag or paper |
Storage Pressure | 4.2 MPa | Spraying Time | ≤10s |
Filling Density | ≤950kg/m3 | Nominal Pressure | 5.3MPa |
Test Pressure | 8.4MPa | Working Power | DC 24V 1.6A |
Working Temperature | 0℃~50℃ | Protected Zone Range | Proportion: ≤800m² ; Volume: ≤3600m³ |
Starting Mode | Automatic, Electrical Manual, Mechanical Manual | Cylinder Volume | 40L、70L、100L、120L、150L、180L |
Brand Name | Air Giant | Model Number | QMP40/4.2, QMP70/4.2, QMP100/4.2, QMP120/4.2, QMP150/4.2, QMP180/4.2 |
Certification | CAL,CMA,CNAS,ILAC-MRA,CCC | Place of Origin | China |
High Light | Archive FM200 Fire Suppression System ,Archive fm200 fire system ,Enclosed Flooding fm200 fire system |
Enclosed Flooding FM200 Fire Suppression System Without Pollution For Archive
HFC-227ea(FM200) clean agent automatic fire suppression system is widely used in China and all over the world. Its most strong point is that this system meets the world’s requirement of environmental protection. It will not hurt the ozone layer even for 1% possibility. The other strong point is that such as the clean, odorless and colorless agent, the easy installation and so on, make it the best substitute for the halon 1301 in people’s mind.
Fm200 gas fire suppression system works more efficient when it is equipped with the electric elements. Besides, this system requires a little storage room outside but next to the protected zone. It helps save places. This system also distinguishes itself by the fast spraying time with less than 10s.
Components
The pipe network model of fm200 fire suppression system consists of actually three parts: the pipe network part, the fire fighting equipment part and the electrical elements part. Here will explain the last two parts for customers.
The electrical elements is a set of detecting device, and it always plays a subsidiary role in each system. The electrical elements includes:several control panels, several manual buttons, some discharge indicator lights, some alarm bells, some sounder with light, some smoke detectors and heat detectors.
The main part of the system is fire fighting equipment. It is formed by several components: fm200 cylinders, a cylinder frame, nitrogen-pressure driving devices, a driving device frame, container valves, flexible hoses, liquid flow check valves, gas control pipes, gas flow check valves, manifolds, safety valves, selective valves, flanges, elbows and nozzles.
Working principle
Here is the illustration of working principle to whole system
Application
The pipe network type fm200 fire suppression system is suitable for a lot of places and several kinds of fires. The followings are some examples for customer as reference:
- Telecommunications and data processing
- Switch gear rooms
- Military applications and cell sites
- High-tech medical application
- Computer rooms
- Telecommunication centers
- Records and data archives
- Testing/imaging equipment
- Reference material
- Chemical laboratories
Advantages
There are a lot of advantages of the single zone fm200 fire suppression system compared to other fire suppression system.
1/ It is the single zone fm200 fire suppression system that can protect the largest volume among the fm200 fire suppression system. Only a single zone system can protect at most 3600 cubic meters.
2/ Using single zone fm200 fire suppression system can help saving money. Obviously, using several systems are more expensive than only using one.
3/ It helps saving place. Because it needs a separate room outside but next to the protected zone, so it won’t waste the places in the protected zone.
4/ The single cylinder has large capacity. It has 120l, 150l, and 180l capacity.
Packages
We always pack it with polyfoam firstly and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.
Company Details
Business Type:
Manufacturer,Exporter,Trading Company
Year Established:
2022
Total Annual:
5000000-10000000
Employee Number:
10~50
Ecer Certification:
Verified Supplier
Introduction: Guangdong Air Giant Fire Equipment Co., Ltd. is an enterprise integrating research and development, design, manufacturing and marketing services, which is specialized in the production of HFC-227ea (pipe network type, piston flow type, cabinet type, hanging type, server-ra... Introduction: Guangdong Air Giant Fire Equipment Co., Ltd. is an enterprise integrating research and development, design, manufacturing and marketing services, which is specialized in the production of HFC-227ea (pipe network type, piston flow type, cabinet type, hanging type, server-ra...
Get in touch with us